• Title/Summary/Keyword: gamma camera

Search Result 292, Processing Time 0.031 seconds

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

The study of collimator and radiation shield for the detection of the gamma-ray distribution (감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.944-945
    • /
    • 2016
  • Gamma-ray Detector for gamma-ray imaging device is composed of a shielding body for shielding gamma-rays incident from the radiation source. Distribution of the gamma ray can be represented by the distribution information on the direction in which the detecting section and the signal through the incident hole of collimator. The role of the shield is important because all signals should be treated as noise except for the signal from the incident hole.In this paper In this paper, we have produced a compact, lightweight and Collimator shield by changing the structure and physical properties with respect to the collimator and shielding of lead-based gamma-ray detectors. And we analyzed the shielding effectiveness relative to the incident gamma ray sphere measured signal value through the gamma irradiation test facility. The results confirmed that the production and Collimator shielding the imaging device Implementing more efficient to implement.

  • PDF

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

Relationship Between Image Quality and Changes in Spation Resolution for the Gamma Camera (감마카메라의 공간분해능 변화와 화질과의 관계)

  • Lee, Man-Koo;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.77-81
    • /
    • 2002
  • The purpose of this study is to examine quantitatively the relationship between visual image quality and degradation In spatial resolution for a gamma camera by the increase in distance from collimator. The relationship between the portion(p) of images identified the difference of image quality and the difference(${\Delta}FWHM$) in FWHM between paired images was showed in a sigmoid curve. Using Dendy's method, minimum level to be correctly identified the difference of Image duality on three out of four occasion(p=0.75) was corresponded to 0.4 mm in ${\Delta}FWHM$. Using fuzzy theory, the level to be identified the difference of image quality was examined under various conditions. The truth-value of fuzzy sets-degraded or slightly degraded and not-degraded in image quality between palled Images-was gained the peak at 0.5 mm of ${\Delta}FWHM$. It was founded that changes of $0.4{\sim}0.5\;mm$ in FWHM-corresponding about 2 cm distance from collimator could be sufficiently identified in the difference of image quality.

  • PDF

Strategies to improve the range verification of stochastic origin ensembles for low-count prompt gamma imaging

  • Hsuan-Ming Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3700-3708
    • /
    • 2023
  • The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a low-count condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a two-layer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a back-projection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.