The study of collimator and radiation shield for the detection of the gamma-ray distribution

감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구

  • Published : 2016.10.27

Abstract

Gamma-ray Detector for gamma-ray imaging device is composed of a shielding body for shielding gamma-rays incident from the radiation source. Distribution of the gamma ray can be represented by the distribution information on the direction in which the detecting section and the signal through the incident hole of collimator. The role of the shield is important because all signals should be treated as noise except for the signal from the incident hole.In this paper In this paper, we have produced a compact, lightweight and Collimator shield by changing the structure and physical properties with respect to the collimator and shielding of lead-based gamma-ray detectors. And we analyzed the shielding effectiveness relative to the incident gamma ray sphere measured signal value through the gamma irradiation test facility. The results confirmed that the production and Collimator shielding the imaging device Implementing more efficient to implement.

감마선 영상화 장치에서 감마선을 탐지하는 검출부는 선원을 바라보는 Collimator와 Collimator 이외의 방향에서 입사되는 감마선을 차폐하기 위한 차폐체로 구성되며 검출센서는 해당 차폐체 내부에 위치하게 된다. 감마선에 대한 분포는 Collimator의 입사구를 통해 들어오는 신호와 검출부가 바라보는 방향에 대한 정보를 통해 분포를 나타낼 수 있다. 때문에 입사구에서 들어오는 신호 외에는 잡음으로 처리해야 하므로 차폐체의 역할이 중요하다. 본 논문에서는 상용 감마선 탐지장치의 보다 축소된 납 기반의 콜리메이터 및 차폐체에 대하여 구조와 물성을 변경하여 소형, 경량화 된 Collimator 및 차폐체를 제작하였다. 또한 감마선 조사시험시설을 이용하여 감마선 입사구의 측정된 신호값을 기준으로 차폐 효율을 분석하였다. 분석결과 제작된 Collimator 및 차폐체가 영상화 장치구현를 구현하는데 보다 효율적임을 확인하였다.

Keywords