• 제목/요약/키워드: furnace

검색결과 3,794건 처리시간 0.027초

Strip Tension Control Considering the Temperature Change in Multi-Span Systems

  • Lee Chang Woo;Shin Kee Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.958-967
    • /
    • 2005
  • The mathematical model for tension behaviors of a moving web by Shin (2000) is extended to the tension model considering the thermal strain due to temperature variation in furnace. The extended model includes the terms that take into account the effect of the change of the Young's Modulus, the thermal coefficient, and the thermal strain on the variation of strip tension. Computer simulation study proved that the extended tension model could be used to analyze tension behaviors even when the strip goes through temperature variation. By using the extended tension model, a new tension control method is suggested in this paper. The key factors of suggested tension control method include that the thermal strain of strip could be compensated by using the velocity adjustment of the helper-rollers. The computer simulation was carried out to confirm the performance of the suggested tension control method. Simulation results show that the suggested tension control logic not only overcomes the problem of the traditional tension control logic, but also improves the performance of tension control in a furnace of the CAL (Continuous Annealing Line).

증착 구간에서의 온도 제어에 따른 SiO2 초미립자의 증착 특성 고찰 (A Study on the Deposition Characteristics of Ultrafine SiO2 Particles by Temperature Control in Deposition Zone)

  • 유수종;김교선
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.157-168
    • /
    • 1996
  • The deposition characteristics of ultrafine $SiO_2$ particles were investigated in a tube furnace reactor theoretically and experimentally controlling tube wall temperature in deposition zone. The model equations such as mass and energy balance equations and aerosol dynamic equations inside reactor and deposition tube were solved to predict the particle growth and deposition. The particle size and deposition efficiencies of $SiO_2$ particles were calculated, changing the process conditions such as tube furnace setting temperature, total gas flow rate inlet $SiCl_4$ concentration and were compared with the experimental results.

  • PDF

EAF Dust Treatment at Miike Smelting CO., LTD.

  • Noda, Shinji;Tatehana, Yoshikazu
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.375-380
    • /
    • 2001
  • MF is a half shaft blast furnace which has been developed at Mitsui Miike Smelter in the 1960’s to treat vertical retort residue. The MF has also been tested for treatment of various recycling materials and wastes. Now various secondaries and wastes (EAF dust, zinc leaching residue, Cu sludge, etc ) are mainly treated. Powder materials are briquetted with reductant before being fed to the furnace. Products are crude zinc oxide, matte, non-hazardous slag and steam. Zinc and lead are recovered in oxide dust, and copper and silver are recovered in matte. The MF can be widely applied to many kinds of materials which contain such non-ferrous metal-valuables. In addition, the improvement in operation and technology has effectively made the unit capacity much larger. The MF now has many advantages for these treatment processes.

  • PDF

The Optimal Composition of Cold Bonded Pellet for Recycling EAF Dust Directly to the Furnace

  • Lee, Kwang-Keun;Kim, Tai-Dong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.370-374
    • /
    • 2001
  • The degree of iron recovery from dust agglomerates was investigated experimentally to determine the optimum mixing ratio of coke in cold bonded pellet(CBP) which is fed into electric arc furnace(EAE) in the minimill plant. From the XRD analysis for EAF dust, magnetite(Fe$_3$O$_4$) and franklinite(ZnFe$_2$O$_4$) was identified as major components. Maximum iron recovery was obtained for the solid carbon content of approximately 18 weight percent. From plant trials of CBP composed of this optimal mixing condition, it was observed that electric power consumption and sulfur content increased with increasing the quantity of CBP.

  • PDF

이온주입 및 열처리 조건에 따른 박막접합의 특성 비교 (Comparison of shallow junction properties depending on ion implantation and annealing conditions)

  • 홍신남;김재영
    • 전자공학회논문지D
    • /
    • 제35D권7호
    • /
    • pp.94-101
    • /
    • 1998
  • To form 0.2 .mu.m p$^{+}$-n junctions, BF$_{2}$ ions with the energy of 20keV and the dose of 2*10$^{15}$ cm$^{-2}$ were implanted into the crystalline and preamorphized silicon substrates. Th epreamorphization was performed using 45keV, 3*10$^{14}$ cm$^{-2}$ As or Ge ions. Th efurnace annealing and rapid thermal annealing were empolyed to annihilate the implanted damage and to activate the implanted boron ions.The junction properties were analyzed with the measured values of the junction depth, sheet resistances, residual defects, and leakage currents. The thermal cycle of furnace annela followed by rapid thermal annela shows better characteristics than the annealing sequence of rapid thermal anneal and furnace annela.Among the premorphization species, Ge ion exhibited the better characteristics than the As ion.n.

  • PDF

공기식 태양열 흡수기의 설계 및 성능평가 (Design and Performance Evaluation of Solar Air Receivers)

  • 조현석;이현진;김종규;이상남;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.280-285
    • /
    • 2012
  • It is important to produce the high temperature and high pressure air for the concentrated solar power system using the combined cycle. In this paper, based on the concept of tubular receiver, we designed two types with focus on radiation loss reduction. These two receivers were tested in the KIER solar furnace of 40kW thermal capacity. Performance of the two receivers were evaluated and compared.

  • PDF

온도구배 측정용 다중접점 열전대 (Multi-junction thermocouple for temperature gradient measurements)

  • 김용규;감기술
    • 센서학회지
    • /
    • 제4권2호
    • /
    • pp.3-6
    • /
    • 1995
  • 항온 유지 장치의 온도구배를 측정하기 위한 다중 접점을 갖는 K형 열전대를 제작하였다. 이 온도계를 사용하여 $800^{\circ}C$로 유지되고 있는 전기로의 온도구배를 측정하였으며, 교정용 기준기급의 S형 열전대와 비교한 결과 K형 열전대의 허용오차 범위 내에서 일치하였다. 더 정확한 온도구배 측정을 위해서는 귀금속 열전대를 사용하는 것이 바람직하다는 것을 제안하였다.

  • PDF

중공 광섬유를 이용한 광섬유 간섭계형 온도센서 (Fiber-optic interferometric temperature sensor using a hollow fiber)

  • 박재희;김광택
    • 센서학회지
    • /
    • 제16권3호
    • /
    • pp.192-196
    • /
    • 2007
  • A fiber-optic interferometric temperature sensor is fabricated using a hollow optical fiber with 8 um air hole. This interferometric sensor for measuring temperature consists of 13 mm long hollow optical fiber whose one end is attached to the single mode fiber and the other end is cleaved. After the sensor is put in a furnace, the phase change of the sensor output signal is measured as the temperature of the furnace increases from $28^{\circ}C$ to $100^{\circ}C$. The phase change of the fiber sensor is proportional to the change of temperature and the relationship between the change of phase and temperature is approximately linear. The sensitivity of this sensor is $2.7{\;}radians/^{\circ}C$.

반응로 내 웨이퍼 배치의 온도장 분석 및 가시화 (Analysis and Visualization of Temperature Field for Wafer Batch in Furnace)

  • 강승환;이승호;김병훈;고한서
    • 한국가시화정보학회지
    • /
    • 제13권3호
    • /
    • pp.24-28
    • /
    • 2015
  • The temperature of the wafer batch in the furnace was calculated and its visualized temperature field was analyzed. The main heat transfer mechanisms from the heater wall to the wafers were radiation and conduction, and the finite difference method was used to analyze the complex heat transfer including those two mechanisms. The visualized temperature field shows that the direction of the heat flux in the wafer batch varies during the heating process, and the heat in the wafer batch diffuses faster by conduction within the wafer than by radiation between the wafers, in the condition of the constant temperature at the heater wall and cap.

Characteristics of arsenic sorption on furnace slag in groundwater

  • S. R. Kanel;Saurabh Sharma;Park, Hechul
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.96-98
    • /
    • 2002
  • Furnace slag, a steel industry waste, has been converted into an inexpensive and efficient adsorbent. The product obtained has been utilized for the removal of arsenic from ground water. Kinetic studies have bepn described with the mechanism of adsorption The results from batch studies showed that the As(III) can be removed from the ground water within the pH range 3-7 However the maximum removal was experienced at pH 7.0. Equilibrium was attained within 24 hours. Adsorption data of arsenic correlate well with the Freundlich and Langmuir adsorption models. The maximum sorption capacity as calculated using Freundlich adsorption isotherm was found to be of 0.004 mg g-1 at pH 7 and $25^{\circ}C$.

  • PDF