• 제목/요약/키워드: furnace

검색결과 3,792건 처리시간 0.028초

폴리실리콘 슬러지와 제지애시를 활용한 무시멘트 경화체의 알칼리자극제 종류 및 혼입율에 따른 강도특성 (Strength properties according to mixing type and ratio Alkali activator of Non-cement matrix using Paper Ash and Polysilicon sludge)

  • 신진현;김태현;김헌태;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.173-174
    • /
    • 2017
  • Recently, many experiments using industrial by-products have been going on in Korea and abroad. Most of the studies on blast furnace slag and fly ash have been conducted, and the blast furnace slag based two and three component experiments have been conducted in many places. Therefore, this study is an additional study of research using polysilicon sludge and paper ash, which is a study using existing industrial by-products based on blast furnace slag, as strength properties of alkali activator according to kind and mixing ratio and to obtain basic data do.

  • PDF

스마트 고로슬래그미분말 혼입 콘크리트의 CO2 배출량 평가에 관한 연구 (The Analysis of CO2 Emission Assessment in Concrete with Smart Blast Furnace Slag)

  • 김태형;태성호;하성균;박정훈;노승준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.43-45
    • /
    • 2012
  • As a part of recent CO2 emission reduction studies in the concrete industry with active use of concrete admixtures with low basic unit of CO2 emission such as blast furnace slag (BFS), basic unit of CO2 emission by SBFS was computed in order to assess CO2 emission by reinforced concrete building with smart blast furnace slag (SBFS). In addition, SBFS concrete was applied to the subject building for assessment of CO2 emission during material production step among construction steps. Life cycle CO2 emission assessment on the subject building was classified into 7cases according to mix ratio of BFS and SBFS.

  • PDF

양생온도가 고로슬래그 콘크리트의 강도발현에 미치는 영향분석 (Effect of curing temperature and blast furnace slag concrete on concrete strength development)

  • 이규동;전명일;이창수;김동식
    • 한국재난정보학회 논문집
    • /
    • 제2권1호
    • /
    • pp.129-137
    • /
    • 2006
  • The present work is attempt to evaluate the temperature dependence of blast furnace slag concrete(BFSC) based on the concrete strength cured with different curing temperatures and ages. A equivalent substitution index(ESI) was induced to explain temperature dependence of concrete quantitatively as well as concrete strength. The results from compressive strength showed substantial crossover effect. which is the phenomenon that the compressive strength cured at low temperature becomes stronger than the one cured at high temperature. The crossover effect found more definitely on BFSC than plain concrete.. The ESI became 1.1 and 1.0 for the BFSC cured at $20^{\circ}C$ and $30^{\circ}C$ after age of 56 days, respectively. Which means that the contribution to strength development of blast furnace slag per unit mass is stronger than that of the Portland cement. It was considered therefore that the optimum curing temperature for BFSC is $20^{\circ}C$.

  • PDF

알칼리 활성화 방법에 따른 고로슬래그 경화체 제조 연구 (Research for the production of blast furnace cement mortar using an alkaline activation method)

  • 신재란;이주열;박병현
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.293-297
    • /
    • 2016
  • This study was performed in order to obtain the effect of the compressive strength of the cured product with manufacturing conditions (amounts of fine aggregate and different types of alkali activator). Material which is the basis of the cured product was used for the blast furnace slag, which has a latent hydraulic activity. Consequently, when using sodium hydroxide as the alkali activator, it is possible to obtain a higher compressive strength than using the calcium hydroxide. And also, it can be added a 10% of fine aggregate with blast furnace slag to improve the compressive strength.

고로 슬래그 미분말을 사용한 고강도 콘크리트의 특성 (Properties of High Strength Concrete Incorporating Fine Blast Furnace Slag)

  • 이봉학;이주형;홍창우
    • 한국농공학회지
    • /
    • 제40권5호
    • /
    • pp.59-67
    • /
    • 1998
  • The object of this study is to investigate the strength characteristics and the freeze-thaw resistance of high strength concrete incorporating fine blast furnace slag. Major experimental variables were the water/cement ratio, maximum size of coarse aggregate, and cement types such as ordinary portland and slag cement. The results were as follows ; The workability of fresh concrete incorporating fine blast furnace slag was better than that of OPC(ordinary Portland cement) in terms of slump. The freeze-thaw resistance showed better than that of OPC, keeping more than 90% of relative modules of elasticity after 506 cycles and showing only a hair crack at surface without serious damage. Thus, the fine blast furnace slag might be recycled at concrete to make high strength concrete at fields.

  • PDF

순환굵은골재, 황토, 고로슬래그 미분말 및 마섬유를 사용한 레인가든 구조물 콘크리트의 최적배합설계 및 역학적 특성 (Optimum Mix Proportion and Mechanical Properties of Rain Garden Structure Concrete using Recycled Coarse Aggregate, Hwang-Toh, Blast Furnace Slag and Jute Fiber)

  • 김동현;박찬기
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.25-33
    • /
    • 2013
  • In this study, the optimum mix proportions of rain garden structure concrete were decided and the mechanical properties were evaluated. Experimental parameters were blast furnace slag, hwang-toh, recycled aggregates and natural jute fibers. The target compressive strength and chloride ion penetration were more than 24 MPa and less than 1000 coulombs, respectively. The response surface method was used for statistical optimization of experimental results. The optimal mixing ratios of the blast furnace slag, hwang-toh, recycled coarse aggregate and jute fiber volume fraction were determined 59.98 %, 8.74 %, 12.12 % and 0.2 %, respectively. The compressive strength, flexural strength and chloride ion penetration test results of optimum mix ratio showed that the 24.56 MPa, 3.88 MPa and 999.08 columbs, respectively.

폐내화물 미분말 치환율이 고로슬래그 미분말과 순환골재 사용 모르타르의 품질에 미치는 영향 (Influence of Replacement Ratio of Wasted Refractory Powder on the Properties of Mortar using Blast Furnace Slag and Recycled Aaggregate)

  • 송원루;백철;김민상;이제현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.38-39
    • /
    • 2016
  • In this research, the possibility of wasted refractory powder pulverized from refractory block as an expansive admixture and additional alkaline stimulant for class two and three blast furnace slag cements (BSC) was assessed with its high content of free CaO or free MgO. As the replacement ratios of wasted refractory powder and blast furnace slag were increased, flow and air content were decreased, while unit volume weight was increased under same conditions. Compressive strength of mortar was increased with increased replacement ratio of wasted refractory powder, especially, in the case of class three BSC, the highest compressive strength was obtained when wasted refractory powder was replaced 10 %.

  • PDF

폐내화물 골재 치환율이 고로슬래그 미분말과 순환골재 사용 모르타르의 품질에 미치는 영향 (Influence of Replacement Ratio of Wasted Refractory Aggregate on the Properties of Mortar using Blast Furnace Slag and Recycled Aggregate)

  • 송원루;문병룡;김민상;이제현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2016
  • In this research, the possibility of wasted refractory aggregate pulverized from refractory block as an expansive admixture and additional alkaline stimulant for class two and three blast furnace slag cements (BSC) was assessed with its high content of free CaO or free MgO. As the replacement ratios of wasted refractory powder and blast furnace slag were increased, flow and air content were decreased, while unit volume weight was increased under same conditions. Compressive strength of mortar was increased with increased replacement ratio of wasted refractory powder, especially, in the case of class three BSC, the highest compressive strength was obtained when wasted refractory aggregate was replaced 2%.

  • PDF

고로 슬래그와 플라이 애시를 혼입한 투수성 폴리머 콘크리트의 공학적 특성(구조 및 재료 \circled2) (Engineering Properties of Permeable Polymer Concrete with Blast Furnace Slag and Fly Ash)

  • 김인수;윤준노;서대석;조일호;한영규;박종화;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.272-277
    • /
    • 2000
  • This study is performed to evaluate the engineering properties of permeable polymer concrete with blast furnace slag and fly ash. The following conclusions are drawn; 1. The highest strength is achieved by 50% filled blast furnace slag powder and fly ash permeable polymer concrete, it is increased 36% by compressive strength, 119% by tensile strength and 217% by bending strength than that of the normal cement concrete, respectively. 2. The ultrasonic pulse velocity is in the range of 2,022 ∼ 2,139m/s. The highest pulse velocity is showed by 50% filled blast furnace slag powder and fly ash permeable polymer concrete. 3. The water permeability is in the range of 4.612∼5.913$\ell$/$\textrm{cm}^2$/h, and it is largely dependent upon the mix design.

  • PDF

제철소용 가열로 내 슬랩 가열 특성의 3차원 비정상 해석 (3D Unsteady Numerical Analysis of Slab Heating Characteristics in a Reheating Furnace for Steel Mill Company)

  • 한상헌;김동민;백승욱;김창영
    • 한국연소학회지
    • /
    • 제11권1호
    • /
    • pp.34-42
    • /
    • 2006
  • Numerical analysis code has been developed to investigate the slab heating characteristics in a reheating furnace of a steel mill company. Unsteady 3-Dimensional behaviour can be predicted with the developed code. Premixed flame model is adopted for combustion phenomena and eddy dissipation model is used for turbulent combustion. Non -gray FVM radiation method is used to get a better accurate radiative solution. Slab movement can be fully traced from entrance into a reheating furnace until it#s exit and computation is performed during that period.

  • PDF