• 제목/요약/키워드: fundamental domain

검색결과 284건 처리시간 0.026초

고전압 펄스 발생 장치의 회로에 관한 이론적 연구 (Theoretical Study of the Circuits for Device of the High Voltage Pulse Generator)

  • 김영주
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.99-108
    • /
    • 2013
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed using Miller's theorem and network theory(ABCD Matrix) and simulated in frequency and time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 1.8kV. Output pulse voltage increases as $L_m$ increases in low voltage circuit. In high voltage circuit, outer capacitors are related to frequency band pass characteristics.

A Study on Integral Equalities Related to a Laplace Transformable Function and its Applications

  • Kwon, Byung-Moon;Ryu, Hee-Seob;Kwon, Oh-Kyu
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.76-82
    • /
    • 2003
  • This paper establishes some integral equalities formulated by zeros located in the convergence region of a Laplace transformable function. Using the definition of the Laplace transform, it shows that Laplace transformable functions have to satisfy the integral equalities in the time-domain, which can be applied to the understanding of the fundamental limitations on the control system represented by the transfer function. In the unity-feedback control scheme, another integral equality is derived on the output response of the system with open-loop poles located in the convergence region of the output function. From these integral equalities, two sufficient conditions related to undershoot and overshoot phenomena in the step response, respectively, are investigated.

지중공동을 고려한 지반-말뚝-구조물 상호작용계의 지진응답해석 (Seismic Response Analysis of Soil-Pile-Structure Interaction System considering the Underground Cavity)

  • 김민규;임윤묵;김문겸;이종세
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.117-124
    • /
    • 2002
  • The major purpose of this study is to determine the dynamic behavior of soil-pile-structure interaction system considering the underground cavity. For the analysis, a numerical method fur ground response analysis using FE-BE coupling method is developed. The total system is divided into two parts so called far field and near field. The far field is modeled by boundary element formulation using the multi-layered dynamic fundamental solution that satisfied radiational condition of wave. And this is coupled with near field modeled by finite elements. For the verification of dynamic analysis in the frequency domain, both forced vibration analysis and free-field response analysis are performed. The behavior of soil non-linearity is considered using the equivalent linear approximation method. As a result, it is shown that the developed method can be an efficient numerical method to solve the seismic response analysis considering the underground cavity in 2D problem.

  • PDF

Filtering of a Dissonant Frequency for Speech Enhancement

  • Kang, Sang-Ki;Baek, Seong-Joon;Lee, Ki-Yong;Sun, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • 제22권3E호
    • /
    • pp.110-112
    • /
    • 2003
  • There have been numerous studies on the enhancement of the noisy speech signal. In this paper, we propose a completely new speech enhancement scheme, that is, a filtering of a dissonant frequency (especially F# in each octave of the tempered scale) based on the fundamental frequency which is developed in frequency domain. In order to evaluate the performance of the proposed enhancement scheme, subjective tests (MOS tests) were conducted. The subjective test results indicate that the proposed method provides a significant gain in audible improvement especially for speech contaminated by colored noise and speaking in a husky voice. Therefore when the filter is employed as a pre-filter for speech enhancement, the output speech quality and intelligibility is greatly enhanced.

혼합유한요소모델을 이용한 두꺼운 복합적층판의 불규칙 진동해석(1)-이론적 고찰 (Random Vibration Analysis of Thick Composite Laminated Plate Using Mixed Finite Element Model (1))

  • 석근영;강주원
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.190-196
    • /
    • 2004
  • Thick composite laminated plates is considered in 3D finite-element. To consider continuity of transverse stresses and displacement field, mixed finite-element has been developed by using layerwise theory and the minimum potential energy principle. Mixed finite-element has been enforced through the thick direction, Z, of a laminated plate by considering six degree-of-freedoms per node. Six degree-of-freedoms are three displacement components in the coordinate axes directions and three transverse stress components ${\sigma}_z,\;{\tau}_{xz},\;{\tau}_{yz}$. The model maintain the fundamental elasticity relations that are stress-strain relation and displacement-strain relation, because the transverse stress components invoked as nodal degrees of freedom by using the fundamental elasticity relationship between th components of stress and displacement. Random vibration analysis of the model is performed by computing consistent mass matrix and computing covariance in frequency domain technique.

  • PDF

고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구 (Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator)

  • 김영주;방상석;이채한;김상현
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.

경계요소법을 사용한 선형 점탄성문제의 해석 (Analysis of linear viscoelastic problems using boundary element method)

  • 심우진;곽병만
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.322-330
    • /
    • 1987
  • 본 논문에서는 전자의 해석중에서 유한요소와 경계요소의 결합으로 생기는 문 제점 그리고 증가된 자요도로 인한 경제성의 손실 등을 고려하여 2차의 경계요소만을 사용한 경계요소법을 시도하였으며 다른 형태의 점탄성기본해 및 점탄성 경계적분식을 유도 사용하였다. 그리고 시도된 방법의 타당성을 보이기 위하여 사용된 예제들(평 면변형문제)의 이론해를 상응원리를 사용하여 유도하였으며 이를 수치결과와 비교하여 근사해의 정확함을 알 수가 있었다.

Virtual boundary element-equivalent collocation method for the plane magnetoelectroelastic solids

  • Yao, Wei-An;Li, Xiao-Chuan;Yu, Gui-Rong
    • Structural Engineering and Mechanics
    • /
    • 제22권1호
    • /
    • pp.1-16
    • /
    • 2006
  • This paper presents a virtual boundary element-equivalent collocation method (VBEM) for the plane magnetoelectroelastic solids, which is based on the fundamental solutions of the plane magnetoelectroelastic solids and the basic idea of the virtual boundary element method for elasticity. Besides all the advantages of the conventional boundary element method (BEM) over domain discretization methods, this method avoids the computation of singular integral on the boundary by introducing the virtual boundary. In the end, several numerical examples are performed to demonstrate the performance of this method, and the results show that they agree well with the exact solutions. So the method is one of the efficient numerical methods used to analyze megnatoelectroelastic solids.

Viscous damping effects on the seismic elastic response of tunnels in three sites

  • Sun, Qiangqiang;Bo, Jingshan;Dias, Daniel
    • Geomechanics and Engineering
    • /
    • 제18권6호
    • /
    • pp.639-650
    • /
    • 2019
  • Time-domain commercial codes are widely used to evaluate the seismic behavior of tunnels. Those tools offer a good insight into the performance and the failure mechanism of tunnels under earthquake loading. Viscous damping is generally employed in the dynamic analysis to consider damping at very small strains in some cases, and the Rayleigh damping is commonly used one. Many procedures to obtain the damping parameters have been proposed but they are seldom discussed. This paper illustrates the influence of the Rayleigh damping formulation on the tunnel visco-elastic behavior under earthquake. Four Rayleigh damping determination procedures and three soil shear velocity profiles are accounted for. The results show significant differences in the free-field and in the tunnel response caused by different procedures. The difference is somewhat decreased when the soil site fundamental frequency is increased. The conventional method which consists of using solely the first soil natural mode to determine the viscous damping parameters may lead to an unsafe seismic design of the tunnel. In general, using five times site fundamental frequency to obtain the damping formulation can provide relatively conservative results.

분산 전원 시스템의 전력품질 향상을 위한 계통연계 인버터의 이중 전류제어 기법 (Dual Current Control Scheme of a Grid-connected Inverter for Power Quality Improvement in Distributed Generation Systems)

  • 김경화
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.33-41
    • /
    • 2015
  • To improve the power quality of distributed generation (DG) systems even in the presence of distorted grid condition, dual current control scheme of a grid-connected inverter is proposed. The proposed current control scheme is achieved by decomposing the inverter state equations into the fundamental and harmonic components. The derived models are employed to design dual current controllers. The conventional PI decoupling current controller is used in the fundamental model to control the main power flow in DG systems. At the same time, the predictive control is applied in the harmonic model to suppress undesired harmonic currents to zero quickly. To decompose the voltage inputs and state variables into the fundamental and harmonic components, the fourth order band pass filter (BPF) is designed in the discrete-time domain for a digital implementation. For experimental verification, 2kVA prototype of a grid-connected inverter has been constructed using digital signal processor (DSP) TMS320F28335. The effectiveness of the proposed strategy is demonstrated through comparative simulation and experimental results.