• Title/Summary/Keyword: frequency-phase method

Search Result 1,647, Processing Time 0.032 seconds

A Simplified Blind Decision Method of Modulation Type in impaired AWGN Channel Environment (Impaired AWGN 채널에서의 간단한 Blind 변조 신호 구분 방식)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • In this paper, a simplified new modulation classification method that utilizes likelihood function for received signal in an impaired AWGN channel environment. The proposed method provides the superior to ML method, although the likelihood under the assumption that each modulated signal is sent utilized. On the other hand, the ML method gets the performance characteristics of high computational complexity and weakness to channel impairment such as phase offsets and frequency offsets. The proposed method has lower computational complexity than that of the ML method. Moreover, the proposed method is robust to the channel impairment such as phase offsets and frequency offsets. The correct classification probabilities of the proposed method and the ML method are given for an AWGN channel with phase offsets and frequency offsets, which were simulated with extensive Monte-Carlo simulation. As shown in simulation resole, a more accurate classification performance both in phase offset environment and in frequency offset can be achieved with the low computational complexity of the proposed method.

A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC (HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법)

  • Ahn, Jong-Bo;Kim, Kook-Hun;Lee, Jong-Moo;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

A Study of the Current-Diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency (가변주파수에 있어서 유도잔동기특성의 도식산정법에 관한 연구 제3보)

  • Min Ho Park
    • 전기의세계
    • /
    • v.18 no.5
    • /
    • pp.20-25
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

The Direct Digital Frequency Synthesizer of Parallel Type Using the Differential Quantization (차동 양자화를 사용한 병렬 방식의 직접 디지털 주파수 합성기)

  • Kim, Chong-Il;Lee, Yun-Sik;Lee, Eui-Kwon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.126-137
    • /
    • 2007
  • In this paper, a new method to reduce the size of ROM in the direct digital frequency synthesizer(DDFS) is proposed. And we design the phase-to-sine converter using the phase accumulator of parallel type for generating the high frequency. The new ROM compression method can reduce the ROM size by using the two ROM. The quantized value of sine is saved by the quantized-ROM(Q-ROM) and the differential ROM(D-ROM). So the total size of the ROM in the proposed DDFS is significantly reduced compared to the original ROM. The ROM compression ratio of 67.5% is achieved by this method. Also, the power consumption is decreased according to the ROM size reduction.

  • PDF

Single-Phase Current Source Induction Heater with Improved Efficiency and Package Size

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.322-328
    • /
    • 2013
  • This paper presents a modified Current Source Parallel Resonant Push-pull Inverter (CSPRPI) for single phase induction heating applications. One of the most important problems associated with current source parallel resonant inverters is achieving ZVS in transient intervals. This paper shows that a CSPRPI with the integral cycle control method has dynamic ZVS. According to this method, it is the Phase Locked Loop (PLL) circuit that tracks the switching frequency. The advantages of this technique are a higher efficiency, a smaller package size and a low EMI in comparison with similar topologies. Additionally, the proposed modification results in a low THD of the ac-line current. It has been measured as less than %2. To show the validity of the proposed method, a laboratory prototype is implemented with an operating frequency of 80 kHz and an output power of 400 W. The experimental results confirm the validity of the proposed single phase induction heating system.

A Theoretical Study for the Thermal Diffusivity Measurement of Solid Material using Photothermal Displacement Method (광열변위법을 이용한 재료의 열확산계수 측정에 대한 이론적 연구)

  • Jeon, Pil-Soo;Lee, Eun-Ho;Lee, Kwang-Jai;Yoo, Jai-Suk;Kim, Ki-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.132-137
    • /
    • 2000
  • A complete theoretical treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in solid materials. The influence of parameters - radius and modulation frequency of pump beam and thickness of material - on the phase lag was studied. The phase decreases up to a certain position, then starts to increase and does have an asymptotic value. The position, where phase has the minimum value, is a function of thermal diffusion length thickness of sample, and radius of pump beam. A new method based on minimum phase lag is described to determine the thermal diffusivity of solid material.

  • PDF

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers (단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.82-90
    • /
    • 1999
  • A pulse frequency control method for single-switch three-phase buck rectifiers is comprehensively studied in this paper. The proposed pulse frequency control method leads the three-phase buck rectifier to a high performance system that can draw the nearly sinusoidal input-line currents. The simulated and experimental results demonstrate that the system provides low total harmonic distortion of the input-line currents, high-power factor, and good output voltage regulation against load change.

Active Tonal Noise Canceller with Frequency Tracking

  • Na, Hee-Seung;Park, Young-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1E
    • /
    • pp.84-88
    • /
    • 1996
  • In this paper, we propose a novel adaptive digital filter for tonal noise cancellation, with a frequency tracking capability. The proposed algorithm not only estimates the magnitude and phase of the tonal disturbance but also tracks its frequency, which changes in quasi-static manner. The algorithm uses the steepest descent method and the instantaneous frequency approach for the phase/magnitude estimation and frequency tracking, respectively. A number of computer simulations have been carried out in order to demonstrate the feasibility of the proposed ANC algorithm under various conditions.

  • PDF

A 64 kHz Frequency Control Using BRM for Induction Heating

  • Jamjan, K.;Thepsatorn, P.;Charean, A.;Tipsuwanporn, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1857-1861
    • /
    • 2003
  • This paper proposes a method for controlling energy distribution to 1 phase induction heating coil by using the Binary Rate Modulation (BRM) Technique. Such method provides proper frequency to the heating coil's requirement by control the frequency at the resonance point, that is, 64-kHZ frequency band. System design are classified to 2 parts. The first part determines main frequency , and the second part generates the frequency from the 8-bit BRM derived from IC no. PAL22V10 in order to control the frequency for Full-bridge connected inverter when supplying the energy required by the 1 phase induction heating coil. Therefore, efficiency of the energy supply can be increate.

  • PDF