• Title/Summary/Keyword: freezing damage

Search Result 286, Processing Time 0.024 seconds

A Study on a Performance evaluation for Quality Liguid Siliceous of Waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • Kang, Hyo-Jin;Kwon, Shi-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs, to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • 강효진;권시원;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liquid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

Evaluation criteria for freezing and thawing of tunnel concrete lining according to theoretical and experimental analysis

  • Moon, Joon-Shik;An, Jai-Wook;Kim, Hong-Kyoon;Lee, Jong-Gun;Lattner, Tim
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.349-357
    • /
    • 2022
  • Abnormal climate events are occurring frequently around the world. In particular, cold waves and heavy snow lead to damage and deterioration of facilities, which can cause loss of life or property damage, such as shortening the lifespan of facilities. Therefore, it is very important to prepare an appropriate maintenance system and to establish a strategy to cope with abnormal weather conditions. In this study, laboratory freezing experiments were performed to analyze the freeze-thaw characteristics affecting the tunnel concrete lining, and heat flow analysis was carried out based on the test results. Based on these experimental and theoretical analysis results, quantitative freeze-thaw evaluation criteria for tunnel concrete linings were proposed.

Study on the Frost Damage of Self-Compacting Concrete in Cold Weather Regions (한랭지에 있어서 고류동콘크리트의 동해에 관한 연구)

  • ;;;;Miura, Takashi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.763-766
    • /
    • 1999
  • The objective of this study was to investigate the influence of low temperature curing on resistance of freezing and thawing of self-compacting concrete placed in cold weather regions. The experimental study results indicated that the self-compacting concrete incorporating ground granulated blast-furnace slag showed good resistance to freezing and thawing, and the self-compacting concrete cellulose viscous agent had relatively poor resistance to freezing and thawing.

  • PDF

An Evaluation on Freezing and Thawing Resistance of Mortars with Bacillus licheniformis (Bacillus licheniformis 균주를 혼입한 모르타르의 동결융해 저항성 평가)

  • Hwang, Ji-Won;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.237-238
    • /
    • 2022
  • This study used Bacillus licheniformis generating glycocalyx as a provective membrane to enhance the salt-damage resistance of cement mortars. The mortar specimens with Bacillus licheniformis exhibited a comparable compressive strength development and 1.1~1.3 times higher dynamic modulus of elasticity under 300 freezing and thawing cycyles when compared with the counterpart control mortar.

  • PDF

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

Regional Distribution of Peach Freezing Damage and Chilling Days in 2010 in Gangwon Province (강원지역의 2010년 복숭아 동해)

  • Seo, Young-Ho;Park, Young-Sik;Cho, Byoung-Ouk;Kang, An-Seok;Jeong, Byeong-Chan;Jung, Yeong-Sang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.225-231
    • /
    • 2010
  • Extremely low values of the daily minimum temperature occurred in January 2010, ranging from -18 to $-29^{\circ}C$ at various locations growing peach trees in the Gangwon province. Due to the extreme cold temperature during the winter dormancy period of peach trees, the growth of the peach trees was damaged and the damaged areas increased as the extent of 17 to 144 ha. In order to provide information on mitigation measure of the cold temperature on the peach trees in the Gangwon province, we assessed the distribution of the damaged areas of growing the peach trees in 2010 and compared it with freezing risk estimated from the dormancy depth of the peach trees and the daily minimum temperature. The dormancy depth of 'Changhowon Hwando (Prunus persica (L.) Batsch)' ranged from -62 to -90 and the freezing risk was greater than 51%. The relationship between the freezing risk and the actual damaged area ratio showed reasonable agreement ($r^2$ of 0.5 with p < 0.01). The results imply that the estimates of the freezing risk based on the dormancy depth can be used as a mitigation measure to identify susceptible peach growing areas to freezing damage injury.

Effect of Freezing on Proteins and Protein Profiles of Sperm Membrane Extracts and Seminal Plasma of Buffalo Bulls

  • Dhanju, C.K.;Cheema, R.S.;Kaur, S.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1678-1682
    • /
    • 2001
  • The total proteins were estimated in both deoxycholate (DOC)-extract of sperm membrane and seminal plasma of chilled as well as frozen semen obtained from five Murrah buffalo bulls. Proteins were further characterized by polyacrylamide gel electrophoresis (PAGE) in three bulls. The protein content of sperm membrane extract (SME) and that of seminal plasma (SP) decreased gradually with increase in freezing period from 6 to 24 mo when compared with the values observed in freshly chilled semen in all bulls. The total decrease in protein content of SME and SP varied from 30-40% and 28-59% respectively during 6-24 mo of freezing. The number of glycoproteins/proteins (GP/P) in SME varied from 4-8 in freshly-chilled semen of all bulls and reduced to 2-4 after 24 mo of freezing. In SP, the number of proteins varied from 6-10 in freshly chilled semen of all bulls and reduced to 3-8 after 24 mo of freezing. Some of the proteins in SME and SP disappeared, others got altered and appeared with change in molecular weight after different freezing times. These studies reveal that alterations in the sperm membrane proteins may be responsible for damage to their membrane during freezing and thus lowering their fertilizability.

STUDIES ON FREEZING OF THE ABALONE 2. Histological Changes by Freezing (전복의 동결에 관한 연구 2) 동결에 의한 전복조직의 변화)

  • SONG Dae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.2
    • /
    • pp.91-95
    • /
    • 1978
  • Histological changes of the abalone muscle occurring in the process of freezing as well as thawing were investigated, and its results were compared to the histological structure of fresh muscle. The muscles of the abalone were mainly composed of smooth muscle fibres, and its morphological structures is similar to those of the top shell. Mechanical damgage of the muscle fibres caused by freezing were not observed while a number of small ice crystals were found between the muscle fibres. The damage by thawing was not much remakable compare to the destruction of muscle fibres of fish.

  • PDF

Evaluation of Ground Water Level Effect on Frost Heaving in Road Pavements (도로 포장체에서 동상에 대한 지하수위 영향 평가)

  • Kweon, Gichul;Lee, Jaehoan
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.47-56
    • /
    • 2013
  • PURPOSES: This study is to evaluate a ground water level effect on frost heaving in road pavements. METHODS: The effects of water table on frost heaving in pavement systems were evaluated from the mechanical analysis using FROST program. The input parameters and boundary conditions were determined by considering climates, pavement sections, and material properties specially subgrade soil types in Korea. RESULTS: When the water table located above the freezing depth, amount of frost heaving caused by freezing the water in pavement itself was big enough to damage in pavement system, although pavement system consists of fully non-frost-susceptible materials with sufficient thickness of anti-freezing layer. The amount of frost heaving was decreased rapidly with increasing the distance between the water table and freezing depth. CONCLUSIONS: It was concluded that there is no engineering problems related with frost heaving in practical sense when the distance between freezing depth and water table is over 1.5m for having subgrade soils less than 50% of #200 sieve passing to meet specification on quality control in Korea.