• 제목/요약/키워드: framed curves

검색결과 16건 처리시간 0.021초

INTEGRAL CURVES CONNECTED WITH A FRAMED CURVE IN 3-SPACE

  • Mustafa Duldul;Zeynep Bulbul
    • 호남수학학술지
    • /
    • 제45권1호
    • /
    • pp.130-145
    • /
    • 2023
  • In this paper, we define some integral curves connected with a framed curve in Euclidean 3-space. These curves include framed generalized principal-direction curve, framed generalized binormal-direction curve, framed principal-donor curve and framed Darboux-direction curve. We obtain some relations between the framed curvatures of new defined framed curves and framed curvatures of given framed curve. By using the obtained relationships we give some characterizations for such curves. We also give methods for constructing framed helix and framed slant helix from planar curves.

ON ADJOINT CURVES OF FRAMED CURVES AND SOME RULED SURFACES

  • Bahar Dogan Yazici;Siddika Ozkaldi Karakus;Murat Tosun
    • 호남수학학술지
    • /
    • 제45권3호
    • /
    • pp.380-396
    • /
    • 2023
  • In this study, we introduce the adjoint curves of framed curves. We examine some characterizations of adjoint curve of a framed curve. In addition, we give the conditions for framed curves and adjoint curves to be Bertrand and Mannheim curves. Then, we introduce adjoint curves of Frenet-type framed curves and give ruled surfaces related to adjoint curves. Finally, we create normal and binormal surfaces of the framed adjoint curves and obtain some characterizations of these surfaces and we support by the results with figures.

보-기둥 접합부의 이력거동을 고려한 RC 평면골조의 내진해석 (Seismic Analysis for RC Framed Structure considering Hysteretic Behavior of Beam-Column Joint)

  • 윤정배;조용부;김영곤;우종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.599-604
    • /
    • 2000
  • The analytical studies for the test results are presented. From experimental envelope curve, hysteretic behaviors under cyclic loading are modelled for beam-column subassemblages. Modelled curves show relatively good reproduction or experimental curves. finally, seismic performances are investigated for 7 story plain framed structure by nonlinear dynamic analysis. The resulting responses are different by each beam-column joint design.

  • PDF

Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios

  • Mazza, Fabio;Mazza, Mirko
    • Earthquakes and Structures
    • /
    • 제13권3호
    • /
    • pp.267-277
    • /
    • 2017
  • Base-isolation is now being adopted as a retrofitting strategy to improve seismic behaviour of reinforced concrete (r.c.) framed structures subjected to far-fault earthquakes. However, the increase in deformability of a base-isolated framed building may lead to amplification in the structural response under the long-duration horizontal pulses of high-magnitude near-fault earthquakes, which can become critical once the strength level of a fire-weakened r.c. superstructure is reduced. The aim of the present work is to investigate the nonlinear seismic response of fire-damaged r.c. framed structures retrofitted by base-isolation. For this purpose, a five-storey r.c. framed building primarily designed (as fixed-base) in compliance with a former Italian seismic code for a medium-risk zone, is to be retrofitted by the insertion of elastomeric bearings to meet the requirements of the current Italian code in a high-risk seismic zone. The nonlinear seismic response of the original (fixed-base) and retrofitted (base-isolated) test structures in a no fire situation are compared with those in the event of fire in the superstructure, where parametric temperature-time curves are defined at the first level, the first two and the upper levels. A lumped plasticity model describes the inelastic behaviour of the fire-damaged r.c. frame members, while a nonlinear force-displacement law is adopted for the elastomeric bearings. The average root-mean-square deviation of the observed spectrum from the target design spectrum together with a suitable intensity measure are chosen to select and scale near- and far-fault earthquakes on the basis of the design hypotheses adopted.

Simplified robustness assessment of steel framed structures under fire-induced column failure

  • Jiang, Binhui;Li, Guo-Qiang;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.199-213
    • /
    • 2020
  • This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.

미세기공 알루미늄 소재의 기계적 성질 (Mechanical Properties of Aluminium Alloy with Cellular Structure.)

  • 윤성원;이승후;강충길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.695-698
    • /
    • 2002
  • Induction heating process is one of the most efficient heating process in terms of temperature control accuracy and heating time saving. In the past study, fabrication process of cellular 6061 alloys by powder metallurgical route and induction heating process was studied. To supplement the framing conditions that studied in past study, effect of induction heating capacity and holding time at foaming temperature were investigated. Under the achieved framing conditions, teamed 6061 alloys were fabricated for variation of foaming temperature, and porosities(%)-foaming temperature curves were obtained by try-error experimental method. Uniaxial compression tests were performed to investigate the relationship between porosities(%) and stress-strain curves of framed 6061 alloy. Also, energy absorption capacity and efficiency were calculated from stress-strain curves to investigated. Moreover, dependence of plateau stress on strain rate was investigated in case of cellular 6061 alloy with low porosities(%)

  • PDF

고(高) 배수량일장(排水量一長) 비(比) V-형(型) 직선늑골선형(直線肋骨船型)의 추진저항성능(推進抵抗性能)에 관(關)하여 (A Study on Resisitance Performance of the Straight-Framed V-Bottom Hull Forms with High Displacement-Length Ratio)

  • 조규종
    • 대한조선학회지
    • /
    • 제6권1호
    • /
    • pp.25-34
    • /
    • 1969
  • From viewpoints of over-all ship economy the straight framed V-bottom hull forms with chines are considered to be attractive even for usual commercial vessels, because increments of resistance over that of round hull forms, if any, can be well compensated with reduction in construction cost.[1] To investigate the influences of both prismatic coefficient and chine elevation on resistance performance, three models of straight-framed V-bottom hull forms which are similar to Prof. C. Ridgely-Nevitt's W-18, W-8, and W-20[2],[3] in size and hull form coefficients were tested at the SNU Ship Model Towing Tank for resistance measurements. They are of Cp=0.60, 0.65 and 0.70 and of ${\Delta}/(0.01L)^3=300$. Influence of variation of chine elevation on resistance performance were observed with the test results obtained at normal condition, and at the trimed by the stern by 2% and 4% of $L_{bp}$ at normal condition under same displacement. The hull form characteristics are shown in Table 1, and in Fig. 1, 2, 3, 4 and 5. The test results are shown in Fig 8, 9 and 10 in the form of Cr vs. $V/\sqrt{L}$ curves taking Cp as a parameter for normal condition, trim by the stern in 2% and 4% $L_{bp}$ at normal condition , respectively. Cr vs. $V/\sqrt{L}$ curves taking trim condition as a parameter are also shown in Fig 11, 12 and 13 for Cp=0.60 and 0.70, respectively. The best and the worst trim condition at given $V/\sqrt{L}$ in viewpoint of Cr are plotted for each Cp-value as shown in Fig 14, 15 and 16. From the above results the following conclusions are derived: (1) In general, the resistance performance of the straight-framed V-bottom hull forms are not inferior to those of round hull forms. At a certain range of $V/\sqrt{L}$ the former gives less resistance than the latter. (2) Regarding influences of Cp on Cr, it is observed that, at $V/\sqrt{L}$ less than about 0.925, the greater Cp-value gives the more increment of Cr, and that, at $V/\sqrt{L}$ greater than about 0.925 the smaller Cp-value gives the more increment of Cr. It is also noteworthy that the model of Cp=0.70 has remarkable hump on Cr vs. $V/\sqrt{L}$ curve between $V/\sqrt{L}=0.80$ and 0.90. (3) For higher speed within the test range, the chine elevation having the steeper slope around bow and the easier slope around amidship and stern, refered to watering, give the better results in resistance performance. (4) Assuming the chine elevations adopted for the tested models were not of the best, we would expect further improvement of resistance performance for such form. Hence, a systematic study on chine elevation is very disirable to prepare design data of general purpose for the such hull forms.

  • PDF

Application of Kelvin's approach for material structure of CNT: Polynomial volume fraction law

  • Hussain, Muzamal
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.129-139
    • /
    • 2020
  • In this piece of work, carbon nanotubes motion equations are framed by Kelvin's method. Employment of the Kelvin's method procedure gives birth to the tube frequency equation. It is also exhibited that the effect of frequencies is investigated by varying the different index of polynomial function. By using volume fraction for power law index, the fundamental natural frequency spectra for two forms of single-walled carbon nanotubes are calculated. The influence of frequencies against length-to-diameter ratios with varying power law index are investigated in detail for these tubes. Throughout the computation, it is observed that the frequency behavior for the boundary conditions follow as; clamped-clamped, simply supported-simply supported and these frequency curves are higher than that of clamped-free curves. Computer software MATLAB is utilized for the frequencies of single-walled carbon nanotubes.

Fragility curves of gravity-load designed RC buildings with regularity in plan

  • Masi, A.;Digrisolo, A.;Manfredi, V.
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.1-27
    • /
    • 2015
  • In this paper Fragility Curves (FCs) relevant to existing RC framed building types representative of the Italian building population designed only to vertical load and regular in-plan have been derived from an extensive campaign of non-linear dynamic analyses. In the generation of the FCs, damage states according to the EMS98 scale have been considered while the intensity measure has been defined by adopting an integral parameter, such as the Housner intensity. FCs have been generated by varying different parameters, including building age, number of storeys, presence and position of infill panels, plan dimensions, external beams stiffness and concrete strength. In order to verify the effectiveness of the damage prediction, comparisons were made between the results obtained from the proposed FCs with those deriving from both prominent fragility studies available in the technical literature and damage distributions observed in past earthquakes. Results show that damage grades obtained by adopting the proposed FCs are generally lower than those provided by the other approaches considered. A comparison with real damage data, shows that the proposed FCs generally estimate more severe damage distributions than those observed in past earthquakes, although they give lower differences with respect to the other approaches.

Seismic performance improvement of RC buildings with external steel frames

  • Ecemis, Ali Serdar;Korkmaz, Hasan Husnu;Dere, Yunus
    • Computers and Concrete
    • /
    • 제27권4호
    • /
    • pp.343-353
    • /
    • 2021
  • In this study, in order to improve the seismic performance of existing reinforced concrete (RC) framed structures, various external attachment of corner steel frame configurations was considered as a user-friendly retrofitting method. The external steel frame is designed to contribute to the lateral stiffness and load carrying capacity of the existing RC structure. A six-story building was taken into account. Four different external corner steel frame configurations were suggested in order to strengthen the building. The 3D models of the building with suggested retrofitting steel frames were developed within ABAQUS environment using solid finite elements and analyzed under horizontal loadings nonlinearly. Horizontal top displacement vs loading curves were obtained to determine the overall performance of the building. Contributions of steel and RC frames to the carried loads were computed individually. Load/capacity ratios for the ground floor columns were presented. In the study, 3D rendered images of the building with the suggested retrofits are created to better visualize the real effect of the retrofit on the final appearance of the façade of the building. The analysis results have shown that the proposed external steel frame retrofit configurations increased the lateral load carrying capacity and lateral stiffness and can be used to improve the seismic performance of RC framed buildings.