Development of an Optical Probe for Measuring Blood Flow in Dental Pulp (치수혈류 측정을 위한 광 프로브 개발)

  • Jang, Kyung-Hwan;Choi, Joon-Yul;Koo, Jeong-Mo;Kwon, Min-Kyung;Kim, Deok-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1204-1209
    • /
    • 2012
  • To diagnose dental pulp vitality, electric pulp tester has been widely used, which is a method to test condition of nerve. However, especially in the case of patients with trauma, nerve desensitization could temporarily occur even though nerve might be recovered by blood flow within the pulp later, which implies that blood flow in dental pulp is also an important factor for diagnosing vitality. This paper described the development of a probe that relatively measured blood flow in dental pulp using photoplethysmography (PPG). The probe emits four different wavelength light sources including three visible and an infrared light. We tested which light source detect sensitively the blood flow in dental pulp. As a result, green light had the largest peak to peak voltage and the power spectrum among different wavelengths.

Frequency of Chromosome Aberrations Detected by Fluorescence in Situ Hybridization Using Triple Chromosome-Specific Probes in o Healthy Korean Population (3중 염색체 probe를 이용한 FISH(fluorescence in situ hybridization)기법으로 분석한 정상인의 염색체 이상빈도)

  • 정해원;김수영;신은희
    • Environmental Mutagens and Carcinogens
    • /
    • v.18 no.2
    • /
    • pp.109-115
    • /
    • 1998
  • Fluorscence in situ hybridization with chromosome-specific probe has been shown to be a valid and rapid method for detection of chromosome rearrangements induced by chemical and physical agents. This method is useful for quantifying structural aberrations, expecially for stable ones, such as translocation and insertion, which are difficult to detect with conventional method in human lymphocyte. In order to use the FISH method as a biodosimeter for monitoring human population exposed to various chemical and physical agent, baseline level of chromosome rearragement was established. Blood from forty four healthy adults were collected and analysed with whole chromosome-specific probes by human chromosome 1,2 and 4. The frequencies of stable translocation were 2.45 per 100 cell equivalent and those of insertion, color juction, acentric and dicentric were 0.32, 3.28, 0.23 and 0.27 per 100 cell equivalent respectively. The frequencies of chromosome rearragements increased with age in both sexes except for dicenrics. From above result, stable aberrations accumulate with age and it may reflect integrated lifetime exposure of adverse environment.

  • PDF

Fatigue damage detection of CFRP using the electrical resistance change method

  • Todoroki, Akira;Mizutani, Yoshihiro;Suzuki, Yoshiro;Haruyama, Daichi
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.4
    • /
    • pp.350-355
    • /
    • 2013
  • Electrical resistance change measurements were performed, to detect fatigue damage of a quasi-isotropic CFRP and cross-ply CFRP laminates. A four-probe method was used to measure the exact electrical resistance change. A three-probe method was used to measure the electrical contact resistance change, during long cyclic loading. The specimen side surface was observed using a video-microscope to detect damage. The measured electrical resistance changes were compared with the observed damage. The results of this study show that the electrical resistance increase of the quasi-isotropic laminate was caused by a delamination crack between ${\pm}45^{\circ}$ plies. Matrix cracking caused a small electrical resistance increase of the cross-ply laminate, but the decreased electrical resistance caused by the shear-plastic deformation impedes matrix-cracking detection.

A Development of Hand Held Type Sheet Resistance Meter by Dual Configuration Method (Dual Configuration Method에 의한 휴대용 면저항 측정기 개발)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Han-Jun;Han, Sang-Ok;Park, Kang-Sic;Koo, Kyung-Wan;Lee, Se-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.929-930
    • /
    • 2007
  • 박막재료 및 반도체의 면저항 측정에는 주로 Four Point Probe(FPP) 원리를 이용한 측정기를 사용하고 있다. FPP에 의한 측정방식은 single 및 dual configuration method가 있으며, dual configuration은 single configuration에 비해 probe spacing 변화나 시료의 가장자리 효과 등에서 측정편차가 적은 장점이 있어서 dual configuration 기술을 사용하는 추세이다. 개발된 휴대용 면저항 측정기는 dual configuration원리를 적용하여 제작되었으며, 박막재료의 면저항을 누구나 쉽고 정확하게 측정할 수 있도록 설계되었다. 또한 시료의 크기가 핀 간격에 비해 5배 이상 크면 보정계수를 거의 무시할 수 있는 장점이 있어 작은 시료라도 정확한 면저항을 측정할 수 있다. 이측정기의 측정 불확도는 지시값의 1 % 이하이고, 측정범위는 (2$\sim$2000)$\Omega/sq$이다.

  • PDF

Quantum theory of multiwave mixing with a local field correction

  • An, Sung-Hyuck;Rhee, Bum-Ku
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.94-99
    • /
    • 1997
  • In this paper, we calculate the four coefficients for the quantum theory of multiwave mixing including a local-field correction resulting from dipole-dipole interactions. We make contact with the semiclassical calculations of probe absorption and four-wave-mixing coupling coefficients, and illustrate the effects of local field corrections on resonance-fluorescence and coupled-mode-fluorescence spectra. The method uses the hybrid quantum-Langevin-equation master-equation approach of An and Sargent.

A Study on Estimation Model of Resistance Value from Change of PTH Crack Size (PTH Crack을 고려한 저항 변화 추정 모델)

  • Kim, Gi-Young;Park, Boo-Hee;Kim, Seon-Jin;Yoo, Ki-Hun;Seol, Dong-Jin;Jang, Joong-Soon;Lee, Hyung-Rok;Kim, Tae-Hyuk
    • Journal of Applied Reliability
    • /
    • v.8 no.4
    • /
    • pp.155-166
    • /
    • 2008
  • PTH cracks are caused by the mismatch of coefficient of thermal expansion(CTE) between polymer and laminated materials, and are one of the main failure mechanisms of multi layer boards. In spite of its importance, it is usually hard to measure or detect them because of its small size and invisibility. To detect PTH cracks more effectively, this paper proposes a theoretical model that can estimate the resistance value from crack size of PTHs. Using four-point probe resistance measurement method, the resistance value of test coupons is measured. Through measured data, we verify the validity of the proposed theoretical model and set up criteria of failure.

  • PDF

Development of an Electromagnetic Actuator for Probe-based Data using Si Storage by Process and Cu Electroplating (실리콘 공정 및 동 도금 기술을 이용한 탐침형 정보저장장치의 전자기력 미디어 구동기 제작)

  • 조진우;이경일;김성현;최영진
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.225-230
    • /
    • 2004
  • An electromagnetic actuator has been designed and fabricated for Probe-based data storage applications. The actuator consists of permanent magnets(SmCo) housing and a media Platform which is connected to the Si frame by four couples of Si leaf springs. In order to generate electromagnetic force, Cu coils were electroplated under the media platform. The magnetic field distribution was calculated with 3D Finite Element Method of Maxwell 3D program. The field strength felt by Cu coils was estimated to be about 0.33T when the distance between the media platform and permanent magnets is $200\mu\textrm{m}$. The static and dynamic motions of the actuator were analyzed by FEM method with ANSYS 5.3. The measured displacements of the actuator were about $\pm$$92\mu\textrm{m}$ for input current of $\pm$40㎃ and the resonance frequency was 100Hz. The proposed electromagnetic actuator can be utilized for media driver of probe-based data storage system.

아르곤4P준위 광방출 분석법(OES)을 이용한 플라즈마의 전자온도 및 준안정 밀도 측정

  • Lee, Yeong-Gwang;Lee, Min-Hyeong;Jeong, Jin-Uk
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.104-108
    • /
    • 2007
  • This paper reviews a simple model and spectroscopic method for extracting plasma electron temperature and argon metastable number density. The model is based on the availability of experimental relative emission intensities of only four argon lines that originate from 4p argon level. In this method, Maxwell-Boltzman distribution for EEDF is assumed and the calculation relies on the accuracy of the cross section. Therefore OES have to be compared with Langmuir probe to establish their practical validity.

  • PDF

Rapid Detection of Enterobacter sakazakii Using TaqMan Real-Time PCR Assay

  • Kang, Eun-Sil;Nam, Yong-Suk;Hong, Kwang-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.516-519
    • /
    • 2007
  • Enterobacter sakazakii is an emerging food pathogen, which induces severe meningitis and sepsis in neonates and infants, with a high fatality rate. The disease is generally associated with the ingestion of contaminated infant formula. In this study, we describe the development of a real-time PCR protocol to identify E. sakazakii using a TaqMan probe, predicated on the nucleotide sequence data of the 168 rRNA gene obtained from a variety of pathogens. To detect E. sakazakii, four primer sets and one probe were designed. Five strains of E. sakazakii and 28 non-E. sakazakii bacterial strains were used in order to ensure the accuracy of detection. The PCR protocol successfully identified all of the E. sakazakii strains, whereas the 28 non-E. sakazakii strains were not detected by this method. The detection limits of this method for E. sakazakii cells and purified genomic DNA were 2.3 CFU/ assay and 100 fg/assay, respectively. These findings suggest that our newly developed TaqMan real-time PCR method should prove to be a rapid, sensitive, and quantitative method for the detection of E. sakazakii.

Effects of Oxygen Plasma Treatment on the Electrical Properties of Organic Photovoltaic Cells (유기 광기전 소자의 전기적 특성에 미치는 산소 플라즈마 처리의 영향)

  • Oh, Dong-Hoon;Lee, Young-Sang;Park, Hee-Doo;Shin, Jong-Yeol;Kim, Tae-Wan;Hong, Jin-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2276-2280
    • /
    • 2011
  • An indium-tin-oxide (ITO) is normally used as a substrate in organic photovoltaic cells. We examined the effects of an oxygen ($O_2$) plasma treatment on the electrical properties of an organic photovoltaic cell. Experiments with four-point probe method and atomic force microscope revealed the lowest surface resistance of 17.64 ${\Omega}$/sq and the lowest average surface roughness of 1.39 nm at the plasma treatment power of 250 W. A device structure of ITO/CuPc/$C_{60}$/BCP/$Cs_2CO_3$/Al was fabricated by thermal evaporation with and without the plasma treated ITO substrate. It was found that the power conversion efficiency of the cell with the plasma treated ITO is 65 % higher than the one without the plasma treated ITO.