• Title/Summary/Keyword: four burners

Search Result 5, Processing Time 0.016 seconds

Stereotype and Effective Cues for Burner-Control Relationship of Four-Stove Range (4구 가스레인지 버너-조종장치 연결에 대한 스테레오타이프 및 효과적 암시 신호)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.2
    • /
    • pp.118-123
    • /
    • 2011
  • This study aims to investigate stereotype and effective cue presentation methods for burner-control relationship of four-stove range for Korean. A total of 381 subjects(male : 262, female : 119) were surveyed using questionnaire, in which eight gas range models drawn by 3-D Max 2010 were presented. The gas range models were labeled by signs(☆#${\triangle}{\square}$) to eliminate suggestive effect of sequential codes such as alphabets and numbers. The results showed that the stereotype was significantly affected by occupation(p < 0.10), but not by subjects' gender and age(p > 0.39). The stereotype of four-burner gas range for Korean was the same as that of Chinese, while the stereotype was different from that of American. The cues with rectangular-shaped arrangements identical or similar to those of burners were effective to relate burners to corresponding controls. The diamond-shaped cues and burner arrangements were not appropriate for representing burner-control relationship of four-stove gas range. These findings would be used as a basic guideline when designing four-burner gas range or similar equipments.

A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler (870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰)

  • Woo, Gwang-Yoon;Kim, Soo-Seok;Park, In-Chan;Ham, Young-Jun;Lee, Eung-Yoon
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • In this study, the boiler efficiency and the change of boiler combustion state with the burner operation of the uppermost layer of 870MW opposite fired coal boiler were measured. Test results showed that the boiler efficiency was high in the order of the uppermost layer simultaneous operation of the front and rear burners, the front burner, and the rear burner operation. When the front and rear burners were operated simultaneously, the heat absorption rate of water walls in the boiler furnace was uniform at four side, and the temperature deviation of the left and right steam on the convection front surface decreased. As the heat absorption rate of the boiler improved, the loss of boiler exhaust gas decreased and the coal supply amount decreased by 8 tons/hour compared to the operation of the rear burner. This will contribute not only to the reduction of fuel cost but also to the reduction of greenhouse gas emissions.

  • PDF

Thermogram analysis of Sasang constitutional Four Burners and primary cancer organ in cancer patients (암환자의 사상체질별 사초 부위와 원발암 부위의 체열 분석 연구)

  • Seo, Young-Kwang;Kim, Eun-Hee;Kim, Sun-Hyung;Kim, Dal-Rae;Choi, Won-Cheol;Lee, Soo-Kyung
    • Journal of Korean Traditional Oncology
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • 1. Objective This study was conducted to research a corelation between the Sasang constitutions and primary cancer organs in cancer patient with their thermography. 2. Method We Analyzed the thermography taken from cancer patients and compared it with their cancer origins and Sasang constitution. 3. Result It was found that there are some relationships between the cancer origins and abnormal skin temperature. Also according to the Sasang constitutions of each cancer patient, the lesion of abnormal skin temperature could be differentiated. 4. Conclusion Thermogram can be affected by both the constitution and the primary cancer organs of the patient. To utilize the thermography as a diagnostic or prognostic method of cancer, further studies are needed.

  • PDF

Relationship between Sasang Constitution and Length of Chest and Abdominal Region (사상체질과 인체 흉복부길이와의 관계)

  • Ahn, Ji-Sun;Park, Sang-Kyun;Yu, Jun-Sang
    • Korean Journal of Acupuncture
    • /
    • v.30 no.2
    • /
    • pp.131-134
    • /
    • 2013
  • Objectives : This study was performed to investigate the relationship between Sasang Constitution and length of chest and abdomen region. Methods : Forty eight participants were enrolled. Weight, height, and lengths from CV22 to CV16, from CV16 to CV8, and from CV8 to CV2 were measured. Ratios of last three lengths to total CV22 to CV2 were calculated respectively. On the other hand, Sasang Constitution was analyzed with QSCCII(Questionnaire of Sasang Constitutional Classification II). The analysis of relationship between the measurements and Sasang Constitution was carried out with SPSS to compare the mean values according to Sasang Constitution. Results : All the mean values were not significantly different depending on the Sasang Constitution, except the ratio of the length from CV16 to CV8 to the length from CV22 to CV2, only in female participants. The ratio was higher in the female Soeumin participants than any other constitutional groups. Conclusions : This result showed that Soeumin could be assumed that they might have weak digestion abilities.

A Study on Flame Extinction and Edge Flame Oscillation in Counterflow Diffusion Flame (대향류확산화염에서 화염소화와 에지화염진동에 관한 연구)

  • Park, Dae-Geun;Yun, Jin-Han;Park, Jeong;Keel, Sang-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.64-76
    • /
    • 2009
  • Experimental and numerical studies are conducted on the characteristics of flame extinction and edge flame oscillation in counterflow diffusion flames. The characteristics of flame extinction and edge flame oscillation are well described varying burner diameter, separation distance between two burners, global strain rate, and velocity ratio. It is verified numerically and experimentally that radial conduction heat loss significantly contributes to flame extinction and edge flame oscillation at low strain rate flames in zero- and micro-gravity. It is also shown that for appropriately small burner diameters flame extinction modes are grouped into four and these are significantly attributed to excessive radial conduction heat loss. The edge flame oscillation can be characterized well by one curve with Strouhal number and Peclet number.