• 제목/요약/키워드: formaldehyde determination

검색결과 32건 처리시간 0.022초

합판용(合板用) 요소수지접착제(尿素樹脂接着劑)의 리조시놀 첨가(添加)에 따른 유리(遊離)포름알데히드 방산(放散) 제거효과(除去效果) (The Scavenging Effect of Resorcinol on the Formaldehyde Release from the Urea Formaldehyde Adhesive Bonded Plywood)

  • 이화형
    • Journal of the Korean Wood Science and Technology
    • /
    • 제8권2호
    • /
    • pp.1-5
    • /
    • 1980
  • This study is carried out to determine the scavenging effect of resorcinol added into the urea formaldehyde resin on the formaldehyde release of plywood, as the preliminary study of using the phenolic substances. The method for formaldehyde determination used in this report is the improved chromotropic acid determination. The results are summarized as follows: 1. Resorcinol added into the urea formaldehyde adhesive acts as a good scavenger. 4 percent of resorcinol reduced the formaldehyde release to less than half content. 2. Adding resorcinol gave better glue shear strength than that of control, showing the peak of the shear strength, at 2 percent and decreased to the same strength as control along its content of 4 percent. 3. Moisture content of air dried plywood met the standard very well.

  • PDF

GC-PDECD를 이용한 공기 중 포름알데하이드의 분석 (Determination of Airborne Formaldehyde Using the Gas Chromatograph-Pulsed Discharge Electron Capture Detector)

  • 김희갑;박미진;김만구
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권2호
    • /
    • pp.117-123
    • /
    • 2002
  • A gas chromatographic method for the determination of airborne formaldehyde was established. In order to be highly detectable with the electron capture detector, formaldehyde was derivatized to its pentafluorobenzyl oxime form by reacting with O- (2,3,4,5,6- pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) at pH of 4.6 and temperature of 50$^{\circ}C$ for 1 hour. Air samples were collected into a Tedlar$\^$(R)/ bag followed by transferring into water contained in two impingers in series. Collection efficiency in the front trap was higher than 90%. Measurement of selected indoor and outdoor air samples showed higher formaldehyde concentrations in indoor air environments and the importance of ventilation for reducing indoor pollution.

Properties of Urea-Formaldehyde Resin Adhesives with Different Formaldehyde to Urea Mole Ratios

  • Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권5호
    • /
    • pp.67-75
    • /
    • 2007
  • As a part of abating the formaldehyde emission of urea-formaldehyde (UF) resin adhesive by lowering formaldehyde to urea (F/U) mole ratio, this study was conducted to investigate properties of UF resin adhesive with different F/U mole ratios. UF resin adhesives were synthesized at different F/U mole ratios of 1.6, 1.4, 1.2, and 1.0. Properties of UF resin adhesives measured were non-volatile solids content, pH level, viscosity, water tolerance, specific gravity, gel time and free formaldehyde content. In addition, a linear relationship between non-volatile solids content and sucrose concentration measured by a refractometer was established for a faster determination of the non-volatile solids content of UF resin. As F/U mole ratio was lowered, non-volatile solids content, pH, specific gravity, water tolerance, and gel time increased while free formaldehyde content and viscosity were decreased. These results suggested that the amount of free formaldehyde strongly affected the reactivity of UF resin. Lowering F/U mole ratio of UF resin as a way of abating formaldehyde emission consequently requires improving its reactivity.

액체 크로마토그래프법에 의한 대기시료중 미량 알데히드류의 정량 (Determination of Trace Aldehydes in Ambient Air by Liquid Chromatography)

  • 이용근;정태우
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.339-349
    • /
    • 1995
  • The purpose on this study is to optimize the chromatographic determination method of trace aldehydes in ambient air. Carbonyl compounds in urban air were trapped at $C_{18}$ DNPH-coated cartridges, and generated hydrazone derivatives were separated by HPLC and detected by UV-vis spectroscopic detector at 360nm. Formaldehyde and acetaldehyde compounds could be isolated from urban(Seoul) air with more than 95% collection efficiency. The analytical detection limits for formaldehyde and acetaldehyde are 0.06pp $b_{v}$, 0.08pp $b_{v}$ for 108 L air samples, respectively. The precision of this method are 3 .sim. 4%(RSD) for mutiple injection of hydrazone standards. Separation of seven dinitrophenylhydrazones could be achieved in appoximately 20 minutes operation time using $C_{18}$ column with apprepriate eluent. The method was applied to the analysis of aldehydes and ketone in Seoul ambient air. The 24-h ambient levels of formaldehyde, acetaldehyde reached up to 6 .sim. 14 and 3 .sim. 8ppbv, respectively. The daily average concentration ratio were 0.60 for acetaldehyde/formaldehyde.yde.

  • PDF

Inhaled Formaldehyde Induces Bone Marrow Toxicity via Oxidative Stress in Exposed Mice

  • Yu, Guang-Yan;Song, Xiang-Fu;Liu, Ying;Sun, Zhi-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5253-5257
    • /
    • 2014
  • Formaldehyde (FA) is an economically important chemical, and has been found to cause various types of toxic damage to the body. Formaldehyde-induced toxic damage involves reactive oxygen species (ROS) that trigger subsequent toxic effects and inflammatory responses, which may increase risk of cancer. Therefore, in the present study, we aimed to investigate the possible toxic mechanism in bone marrow caused by formaldehyde. In accordance with the principle of randomization, the mice were divided into four groups of 6 mice per group. One group was exposed to ambient air and the other three groups were exposed to different concentrations of formaldehyde (20, 40, $80mg/m^3$) for 15 days in the respective inhalation chambers, 2h a day. At the end of the 15-day experimental period, all mice were killed. Bone marrow cells were obtained. Some of those were used for the determination of blood cell numbers, bone marrow karyote numbers, CFU-F, superoxide dismutase (SOD) activity and malondialdehyde (MDA) content; others were used for the determination of mitochondrial membrane potential (MMP), cell cycle and Bcl-2, Bax, CytC protein expression. WBC and PLT numbers in median and high dose groups were obvious reduced, but there was no change on RBC numbers. There was also reduced numbers of bone marrow karyotes and CFU-F in the high dose group. SOD activity was decreased, but MDA content was increased. MMP and Bcl-2 expression were decreased with increasing formaldehyde concentration, while expression of Bax and Cyt C was increased. We also observed change in cell cycling, and found that there was S phase arrest in the high dose group. Our study suggested that a certain concentration of formaldehyde could have toxic effects on the hematopoietic system, with oxidative stress as a critical effect.

Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발 (Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • 제13권5호
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

Determination of Ultratraces of Rhodium by Adsorptive Stripping Voltammetry of Formaldehyde Complex

  • Hong Tae-Kee;Czae Myung-Zoon;Lee Chul;Kwon Young-Soon;Hong Mi-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권12호
    • /
    • pp.1035-1037
    • /
    • 1994
  • An ultrasensitive and selective stripping voltammetric scheme for the determination of rhodium is described. By the use of combined accumulation and catalytic effects in formaldehyde-hydrochloric acid medium, substantial improvement in the limit of detection can be obtained. Optimal experimental conditions were found to be 0.42 M hydrochloric acid solution containing 0.008${\%}$ formaldehyde, an accumulation potential of -0.70 V (vs. Ag/AgCl) and an accumulation time of 20 s. The stripping mode was differential pulse voltammetry. In these conditions the limit of detection lies at 2 ${\times}$ l0$^{-12}$ M (0.21 ppt). The relative standard deviation at 5 ${\times}$ l0$^{-11}$ M was 4.9${\%}$ (n=5). There were no serious interferences from other platinum group metal ions being the tolerable amounts more than 500 times that of rhodium.

Validation and Determination of the Contents of Acetaldehyde and Formaldehyde in Foods

  • Jeong, Hye-Seung;Chung, Hyun;Song, Sang-Hoon;Kim, Cho-Il;Lee, Joon-Goo;Kim, Young-Suk
    • Toxicological Research
    • /
    • 제31권3호
    • /
    • pp.273-278
    • /
    • 2015
  • The aim of this study was to develop an efficient quantitative method for the determination of acetaldehyde (AA) and formaldehyde (FA) contents in solid and liquid food matrices. The determination of those compounds was validated and performed using gas chromatography-mass spectrometry combined by solid phase micro-extraction after derivatization with O-(2,3,4,5,6-pentafluoro-benzyl)-hydroxylamine hydrochloride. Validation was carried out in terms of limit of detection, limit of quantitation, linearity, precision, and recovery. Then their contents were analyzed in various food samples including 15 fruits, 22 milk products, 31 alcohol-free beverages, and 13 alcoholic beverages. The highest contents of AA and FA were determined in a white wine (40,607.02 ng/g) and an instant coffee (1,522.46 ng/g), respectively.

헤드스페이스-가스크로마토그래피-질량분석법에 의한 체모 중 포름알데하이드 측정법 연구 (The Study on the Measurement of Formaldehyde in Hair by HS-GC-MS)

  • 신호상;안혜실
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.67-70
    • /
    • 2006
  • A gas chromatography/mass spectrometric method was developed for the determination of formaldehyde in hair. 0.3mg of hair was placed in 10ml headspace vial. 1.5mM pentafluorophenylhydrazine solution (pH 2) in 0.03 M phosphoric acid and $20\;{\mu}l$ of 500 mg/l $acetone-d_6$ as internal standard were added in vial and sealed tightly with cap. The solution was heated for 30 min at $90^{\circ}C$ in heating block. The extraction, the derivatization and the evaporation were performed simultaneously. After heating of the solution, 0.5 ml of headspace was taken up and analyzed by gas chromatography-mass spectrometry (GC-MS). Low limit of detection (LaD) and Low limit of quantitation (LOQ) of formaldehyde were 0.5 and 1.5 ng/g, respectively. The method was used to analyze formaldehyde in rat hair after oral exposure. The developed method may be valuable to be used to analyze formaldehyde in human hair.

Determination of Formaldehyde in Cigarette Smoke and Inhibitory Effect of Plant Volatile Extracts on the Formation of Formaldehyde

  • Her, Jae-Young;Jang, Hae-Won;Lee, Kwang-Geun
    • Food Science and Biotechnology
    • /
    • 제18권2호
    • /
    • pp.471-474
    • /
    • 2009
  • Formaldehyde (FA) is a carcinogenic compound present in cigarette smoke. In this study, the amount of formaldehyde was analyzed in 5 kinds of cigarettes and the inhibitory effect of plant volatile extracts on the formation of FA was investigated. After extraction of the cigarette sample, FA was converted into its thiazolidine derivatives by reaction with cysteamine, and then measured using a gas chromatography-nitrogen phosphorus detector (GC-NPD). The concentrations of FA in cigarette smoke were found between 138.24 and $217.82{\mu}mol/g$ cigarette smoke. Extracts isolated from Welsh onion (Allium cepa L.), garlic (Allium sativum L.), crown daisy (Chrylsanthemum coronarium L.), green pepper (Capsicum annuum L.), and sesame dropwort (Oenanthe javanica DC) were used for analyzing their inhibitory effects on the formation of FA. The inhibitory effects of extracts of Welsh onion, garlic, crown daisy, green pepper, and sesame dropwort on the formation of FA were 64, 47, 38, 47, and 19%, respectively.