• Title/Summary/Keyword: flux noise

Search Result 261, Processing Time 0.032 seconds

Annealing Effects of Amorphous Cores for the Application of Flux-gate Sensors (Flux-gate 센서용 비정질 코아의 열처리효과)

  • 김용준;손대락;손동환
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.134-140
    • /
    • 2001
  • Flux-gate magnetometer was developed in 1930's, and it has been widely used for the low magnetic field measurements. In this work, we have employed amorphous ribbon 2714A produced by Allied Chem. Co. as sensor core material. To develop low noise, low power consumption, and high reliability flux-gate magnetometer, we have measured ac magnetic properties depending on the annealing conditions. As quenched state amorphous core shows high noise level and ac magnetic properties were changed under the condition of accelerated aging test, but amorphous ribbon, which was annealed under 350 $\^{C}$ during 1 hour, shows low noise level of 0.1 nT in the frequency range of dc∼10 Hz which was 10 times better than the as quenched amorphous ribbon. Under accelerated aging test, ac magnetic properties such as squareness and coercivity of the annealed samples show higher reliability and approached to a certain limiting value as exponential function. We can see that high reliability and low noise flux-gate magnetometer could be developed, if we consider this ac magnetic properties change in the sensor design.

  • PDF

A study on the Measurement of Residual Flux for Transformer (변압기 잔류자속 측정에 관한 연구)

  • Kim, Young-Hak
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.133-138
    • /
    • 2022
  • In previous studies to obtain the residual magnetic flux of the transformer using the leakage magnetic flux, a transfer function was used. The transfer function was consisted with the leakage magnetic flux measured outside the transformer and the residual magnetic flux measured at the moment passing through the two ± residual points. In this study, a method of calculating the ratio of the maximum operating leakage flux to the residual leakage flux was proposed The advantage of this method is to avoid the uncertainty of the transfer function due to current noise. Then, the noise of the sensor was measured to investigate the effect of the drift of the noise on the measurement results. Comparing the residual leakage magnetic flux density with 80nT of the drift noise, 66 times or more at a distance of 10 mm and 5 times or more at a distance of 100 mm were obtained. 100mm was the maximum measurement distance to obtain the residual magnetic flux.

ADAPTIVE PI FUZZY CONTROLLER FOR INDUCTION MOTOR USING FEEDBACK LINEARIZING METHOD

  • Motlagh, Muhammad Reza Jahed;Hajatipour, Majid
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.514-518
    • /
    • 2005
  • In this paper an adaptive fuzzy PI controller with feedback linearizing meth od is implemented to controlling flux and torque separately in induction motor. In this paper first decoupling of torque and flux which are outputs to be controlled, is achieved by using feedback linearization methodology. Then for reducing the effect of noise and rejection of disturbance, main part of controller which is adaptive PI fuzzy controller, is designed. Coefficients of PI controller are determined by defined fuzzy rules due to error dynamic. Inputs of fuzzy system are defined sliding surfaces which consist of torque and flux errors. The main contribution of this paper is effect reduction of noise and disturbance on torque and flux which is based on fuzzy logic and nonlinear control. At last the effectiveness of the proposed control scheme in presence of noise and load disturbance is simulated and comprised to applying sliding method. The results verify better effectiveness of the proposed method for effect reduction of noise and disturbance.

  • PDF

A Study on the Influence Coaxial Parallel Magnetic Field upon Plasma Jet (II) (Plasma Jet의 동축평행자계에 의한 영향에 관한 연구 2)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.22 no.5
    • /
    • pp.19-32
    • /
    • 1973
  • This paper treats with some of plasma jet behaviors under magnetic field for the purpose of controlling important characteristics of plasma jet in the practices of material manufacturings. Under the existence and non-existence of magnetic field, the pressure distribution, flame length, stability and noise of plasma jet are comparatively evaluated in respect of such parameters as are current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle. The results are as follows: 1) the pressure, the length and the noise of plasma jet rise gradually with the increase of are current, and have high values under identical arc current as the diameter of nozzle increases, but reverse phenomenon tends to appear in the noise. 2) The pressure, the flame length and the noise increase with the increased quantity of argon flow, and the rising slope of noise is particularly steep. Under magnetic field, the quantity of argon flow in respect of flame length has the critical value of 80(cfh). 3) The pressure and length of flame decrease with small gradient value as the length of gap increases, but the noise tends to grow according to the increase of nozzle diameter. 4) The pressure and the length of jet flame decrease inversly with the increase of magnetic flux density, which have one critical value in the 100 amps of arc current and two values in 50 amps. The pressure of jet flame can be below atomospher pressure in strong magnetic field. 5) "The constriction length of nozzle has respectively the critical value of 6(mm) for pressure and 23(mm) for the length of flame. 6) Fluctuations in the wave form of voltage become greater with the increase of argon flow and magnetic flux density, but tends to decrease as arc current increases, having the frequency range of 3-8KHz. The wave form of noise changes almost in parallel with that of voltage and its changing value increases with argon flow, arc current and magnetic flux density, having the freuqency range of 6-8KHz. The fluctuation of jet presurre is reduced with the increase of argon flow and magnetic flux density and grows with arc current.rent.

  • PDF

Low Frequency Noise Properties of YBCO SQUID Gradiometers (YBCO SQUID gradiometers의 저주파 잡음 특성 연구)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.68-73
    • /
    • 2002
  • We have fabricated YBCO SQUID 1st order gradiometers on $30^{\circ}$STO bicrystal substrate. The pickup coil size was 3.8mm$\times$3.8mm and baseline was 5mm. Three types of SQUID gradiometer were designed and tested for unshielded operation; solid pickup coil, pickup coil consisting of 4 parallel $ 50\mu\textrm{m}$-wide loops, and solid pickup coil with flux dam. We have investigated external magnetic field dependence of the SQUID gradiometers on the magnetic field noiseproperties. Significant increase of low frequency noise with the application of static field has been observed in the case of parallel and flux dam type pickup coil above threshold field of $1.3 \mu$T. Magnetic field noise at 1 Hz measured in the magnetically shielding room was 30, 165, 480 fTcm/sup -1/Hz/sup -1/2/ for solid type and slot type and parallel loops type, respectively.

  • PDF

Reduction of Vibration and Noise of BLDC Motors by Realizing Sinusoidal Air-Gap Flux Density Distribution (BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 진동.소음 저감)

  • Kim, Samuel;Jeong, Seung-Ho;Kwon, Byung-Il;Kim, Hong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.95-97
    • /
    • 2006
  • Cogging torque is often a principal source of vibration, noise and difficulty of control in BLDC motors. Therefore, this paper will present a design method of magnetization system with sinusoidal air-gap flux density distribution of Nd-Fe-B magnets in ring type for reduction of Vibration and Noise and low manufacturing cost.

  • PDF

Design and Analysis of a Permanent Magnet Biased Magnetic Levitation Actuator (영구자석 바이어스 자기부상 구동기 설계 및 해석)

  • Na, Uhn Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.875-880
    • /
    • 2016
  • A new hybrid permanent magnet biased magnetic levitation actuator (maglev) is developed. This new maglev actuator is composed of two C-core electromagnetic cores separated with two permanent magnets. Compared to the conventional hybrid maglev actuators, the new actuator has unique flux paths such that bias flux paths are separated with control flux paths. The control flux paths have minimum reluctances only developed by air gaps, so the currents to produce control fluxes can be minimized. The gravity load can be compensated with the permanent magnet bias fluxes developed at off-centered air gap positions while external disturbances are controlled with control fluxes by currents. The consumed power to operate this levitation system can be minimized. 1-D magnetic circuit model is developed for this model such that the flux densities and magnetic forces are extensively analyzed. 3-D finite element model is also developed to analyze the performances of the maglev actuator.

Modeling of Flux Leakage in a Magnetic Circuit with Permanent Magnet (영구자석을 포함한 자기회로에서의 누설 자속 모델링)

  • Kim, Seung-Jong;Kim, Woo-Yeon;Lee, Jong-Min;Bae, Yong-Chae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The magnetic circuit analysis excluding flux loss and fringing effect often gives a result with unignorable error, when compared with real system. But, it is not easy to make a complete magnetic circuit model with the loss effects. This paper introduces a relatively simple method to build the model including the flux loss and fringing effect, in which the paths of leaked flux are simplified in terms of circular arcs and straight lines. After modification of the model, the error of about 36 % in maximum between the magnetic circuit analysis and FEM analysis is reduced to about 7 %.

Analysis of Noise Source for Mold Transformer (몰드변압기의 소음 원인 분석)

  • Choi, W.H.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.59-64
    • /
    • 2000
  • Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

  • PDF