• Title/Summary/Keyword: fluid and flow

Search Result 7,252, Processing Time 0.052 seconds

A Study of Cooling of Mobile Phone Using PCM Module (상변화 물질을 이용한 이동전화기의 냉각에 관한 연구)

  • Lee, Sang-Jin;Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1173-1181
    • /
    • 2005
  • The cooling effect of a mobile phone using PCM(Phase Change Material) module has been numerically investigated. A transient three-dimensional numerical analysis of heat and fluid flow with natural convection is performed in this study. Governing conservation equations for mass, momentum and energy are solved by an implicit finite volume method. An enthalpy-porosity technique has been used for modeling of the melting process. Two different ways of placing the PCM module are considered. One is to place a PCM module between the substrate and battery pack, and the other is to place a PCM module between MCM(multichip module) and battery pack. Three different types of PCMs are used to predict the performance of PCM. The results show that passive cooling with PCM can reduce the temperature rise and the effect of natural convection in PCM module considered in this study is negligible.

A Study on the Modal Characteristics of Submerged Circular-tube-beam by Experiment (원형중공빔 접수진동특성의 실험적 고찰)

  • Kim, Hyun-Soo;Kang, Yun-Ki;Lee, Young-Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.276-276
    • /
    • 2003
  • This paper dealt with an experimental study on the free vibration of circular-tube-beam submerged in water. A circular-tube-beam is commonly founded on the nuclear fuel assembly system in nuclear reactor. The nuclear fuel assembly susceptible to flow-induced vibration in nuclear reactor. So, the nuclear fuel assembly be designed to avoid any resonance due to the vibration during the reactor operation. In the experiment, applied boundary condition is clamped-free and the effect of water height to natural frequency and damping is studied. The experiment in air and in water has been performed. Used experimental method is impact exciting method. The natural frequencies and damping ratio according to water height is presented.

  • PDF

NUMERICAL IMPLEMENTATION OF THE TWO-DIMENSIONAL INCOMPRESSIBLE NAVIER-STOKES EQUATION

  • CHOI, YONGHO;JEONG, DARAE;LEE, SEUNGGYU;KIM, JUNSEOK
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.19 no.2
    • /
    • pp.103-121
    • /
    • 2015
  • In this paper, we briefly review and describe a projection algorithm for numerically computing the two-dimensional time-dependent incompressible Navier-Stokes equation. The projection method, which was originally introduced by Alexandre Chorin [A.J. Chorin, Numerical solution of the Navier-Stokes equations, Math. Comput., 22 (1968), pp. 745-762], is an effective numerical method for solving time-dependent incompressible fluid flow problems. The key advantage of the projection method is that we do not compute the momentum and the continuity equations at the same time, which is computationally difficult and costly. In the projection method, we compute an intermediate velocity vector field that is then projected onto divergence-free fields to recover the divergence-free velocity. Numerical solutions for flows inside a driven cavity are presented. We also provide the source code for the programs so that interested readers can modify the programs and adapt them for their own purposes.

A numerical study of natural convection for low Pr liquids in enclosures with rocking (요동이 있는 밀폐용기내 낮은 Pr 액체의 자연대류에 관한 수치적 연구)

  • Mo, Jeong-Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.360-372
    • /
    • 1998
  • This study deals with the interaction between buoyancy-induced convection and externally imposed excitation in the form of harmonic rocking and the effect of the interaction upon heat transfer in low-Pr liquids. A wide array of system responses are discussed using the spectral collocation numerical technique. The superposition of buoyancy and Coriolis forces leads to complex fluid flow and heat transfer. The transition to chaotic convection is accelerated, and heat transfer rates are reduced as the enclosure is excited at the fundamental frequency of oscillation associated with the pure buoyancy-driven case. Average heat transfer rates are correlated for Pr=0.02 and 0.03. The heat transfer is affected more in the Pr=0.03 liquid than the case of Pr=0.02.

Evaluation on the Efficiency of Cored Wire Feeding in Addition of Alloying Elements into Cu Melt (코어드 와이어 피딩에 의한 Cu 용탕에의 합금 첨가 시 효율 평가)

  • Kang, Bok-Hyun;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.33 no.6
    • /
    • pp.248-253
    • /
    • 2013
  • To add alloying elements into a pure copper melt, the wire-feeding efficiency of cored (alloy containing) wire was evaluated using a commercial, computational fluid-dynamics program. The model design was based on an industrial-scale production line. The variables calculated included wire feed rate, melt temperature, wire diameter, melt flow rate and wire temperature. Efficiency was evaluated after a series of calculations based on the penetration depth of the alloy-wire into the molten copper bath. Of the five variables investigated, the wire feed rate and wire diameter were the most influential factors affecting the feeding efficiency of the cored-wire.

Design Technology and Performance Characteristics of Small Scale Two-Dimensional Centrifugal Compressor (초소형 2차원 원심압축기의 설계 및 성능특성)

  • Cho, Hyung-Hee;Choi, Hang-Cheol;Kim, Kwang-Ho;Chung, Jin Taek
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.405-410
    • /
    • 2004
  • 2-dimensional impeller's distinctive feature is expected to have an influence on performance and flow characteristics of centrifugal compressor. And new design method is required for 2-dimensional impeller, because the unique geometry cannot be designed using conventional theories. The objective of this study is to advance new design technology for 2-dimensional impeller and to investigate the performance characteristics of designed 2-dimensional centrifugal compressor. The performance test for 2-dimensional impeller is conducted at 35000, 40000 and 45000rpm. Also numerical calculation is applied by using commercial CFD code, FLUENT, and the results are compared with experimental results.

  • PDF

Analysis of Operation Performance of a Micro Gas Turbine Generator System (마이크로 가스터빈 발전시스템의 운전성능 분석)

  • Lee, J. J.;Kim, T S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.132-139
    • /
    • 2004
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. On the basis of the measured data, analytical approach is tried to estimate design characteristic and performance parameters such as component efficiencies and unmeasured temperatures.

  • PDF

Nonlinear Dynamic Analysis of a Cantilever Tube Conveying Fluid with System Identification (시스템 규명을 통한 외팔 송수관의 비선형 동적 거동 해석)

  • 임재훈;정구충;최연선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.495-500
    • /
    • 2003
  • The vibration of a flexible cantilever tube with nonlinear constraints when it is subjected to flow internally with fluids is examined by experiment and theoretical analysis. These kind of studies have often been performed that finds the existence of chaotic motion. In this paper, the important parameters of the system leading to such a chaotic motion such as Young's modulus and coefficient of viscoelasticity in tube material are discussed. The parameters are investigated by means of a system identification so that comparisons are made between numerical analysis using the parameters of a handbook and the experimental results. The chaotic region led by several period-doubling bifurcations beyond the Hopf bifurcation is also re-established with phase portraits and bifurcation diagram so that one can define optimal parameters for system design.

  • PDF

Evaluation of Thermal Environment on Air-barrier Type Perimeter-less System with Underfloor Air Conditioning System (바닥급기 공조시 에어베리어형 페리미터레스 공조시스템의 실내 열환경 평가)

  • 김용경;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.346-351
    • /
    • 2003
  • This paper aims at suggesting design guidelines for a perimeter-less HVAC system that contributes energy savings. Perimeter-less HVAC system is one that relieves difficulties fuck as handling mixing loss, uneven radiative environment, and maintenance and repair. It prevents heat load gained through window and outdoor wall without modifying a previously equipped building skin system. In this paper, we performed several kinds of CFD (computational fluid dynamics) cases through numerical simulation to obtain an optimized perimeter-less design, and then we conducted a large-scale model experiment to see how the push-pull air flow would handle indoor heat to obtain an optimized perimeter-less design.

Study on Non-uniform Thermal Comfort in Hybrid Air-Conditioning System with CFD Analysis (CFD 해석을 통한 하이브리드 공조시스템의 인체 온열감의 불균일성에 관한 연구)

  • Nam, Yu-Jin;Sung, Min-Ki;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.216-222
    • /
    • 2011
  • Recently, hybrid air-conditioning system has been proposed and applied to achieve building energy saving. One example is a system combining radiation panel with natural wind-induced cross-ventilation. However, few research works have been conducted on the non-uniformity of thermal comfort in such hybrid air-conditioning system. In this paper, both thermal environment and non-uniform thermal comfort of human thermal model under various air-conditioning system, including hybrid system, were evaluated in a typical office room using coupled simulation of computation fluid dynamics, radiation model and a human thermal model. The non-uniformity of thermal comfort was evaluated from the deviation of surface temperature of human thermal model. Flow fields and temperature distribution in each case were represented.