• Title/Summary/Keyword: fluid and flow

Search Result 7,251, Processing Time 0.036 seconds

Fluid Flow and Temperature Distribution Around a Surface-Mounted Module Cooled by Forced Air Flow in a Portable Personal Computers (휴대용 컴퓨터 내에 실장된 강제공랭 모듈 주위의 유체유동과 온도분포)

  • Park,Sang-Hee;Shin, Dae-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.238-246
    • /
    • 2004
  • This paper reports an experimental study around a module about forced air flow by blower (35${\times}$35${\times}$6㎣) in a portable personal computer model(200${\times}$235${\times}$10㎣). Experimental report is to know three data to investigate thermal resistance, adiabatic wall temperature and visualized fluid flow around the module by combination of the moving number and the arrangement method of blower. The channel inlet flow velocity has been varied between 0.26, 0.52 and 0.78㎧, and input power ( $Q_{p}$) to the module is 4W. To investigate thermal resistance. the heated module is mounted on two boards(110${\times}$110${\times}$1.2㎣, k=20.73, 0.494W/ $m^{\circ}C$) in parallel-plate channel to forced air flow. The temperature distribution were visualized by heated module on acrylic board(k=0.262W/ $m^{\circ}C$) using liquid crystal film. Fluid flow around the module were visualized using particle image velocimetry system.

Estimation and Application of Turbulent Flow-Induced Input Power for Vibrational Power Flow Analysis (진동파워흐름해석을 위한 난류흐름에 의한 입력파워 추정 및 적용)

  • Lim, Gu-Sub;Hong, Suk-Yoon;Park, Young-Ho;Choi, Young-Dal;Joung, Tea-Seok
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2008.09a
    • /
    • pp.96-105
    • /
    • 2008
  • Turbulent flow-induced vibrations generate the structural fatigue and noise problems. In this paper, using Corcos, Smol' yakov-Tkachenko, Ffowcs Williams and Chase models, the input power generated by distributed fluid force is predicted for power flow analysis (PFA) of turbulent flow-induced vibration. Additionally, the Fast Fourier Transform (FFT) is used to raise the calculation efficiency PFA results obtained are compared with the classical modal solutions for verifications. Analytic results using the fluid models show good agreements with those of modal analysis, respectively.

  • PDF

Unsteady Flows Arising in a Mixed-Flow Vaneless Diffuser System

  • Tsurusaki, Hiromu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.92-100
    • /
    • 2008
  • The main objective of this study was to clarify the origin of the unsteady flows arising in a mixed-flow vaneless diffuser system and also the effects of physical components of the system. The testing equipment consists of a straight tube, a swirl generator, and a mixed-flow vaneless diffuser. Pressure fluctuations of the flow through the tube and diffuser were measured by using a semiconductor-type pressure transducer and analyzed by an FFT analyzer. In the experiment, the velocity ratio (axial velocity/peripheral velocity) of the internal flow, and the geometric parameters of the diffuser were varied. Two kinds of unsteady flows were measured according to the combination of the components, and the origin of each unsteady flow was clarified. The fundamental frequencies of unsteady flows arose were examined by two-dimensional small perturbation analysis.

Modeling of MR Damper Landing Gear Considering Incompletely Developed Fluid Flow (불완전 발달 유체 유동을 고려한 MR댐퍼 착륙장치 모델링)

  • Lee, Hyo-Sang;Jang, Dae-Sung;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.7-18
    • /
    • 2021
  • A semi-active MR damper landing gear is a damper that generates a fluid damping force and a magnetic field control damping force when the MR fluid passes through annular flow paths. In the case of MR fluid passing through annular flow paths, an incompletely developed flow inevitably occurs, causing an error in calculating damper inner forces including the fluid damping force. This error results in an inaccurate design of damper structural parameters and control gain selection, resulting in deterioration of dynamic characteristics and shock absorption performance of the landing gear. In this paper, we derived a mathematical model of an MR damper landing gear considering additional damping force generated in the entrance region of annular flow paths of the MR damper. If the mathematical modeling derived from this paper is applied to the design and optimization process of an MR damper landing gear, excellent performance of the MR damper landing gear is expected.

Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor (2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동)

  • Kang, Kyung-Jun;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

A Comparison of Surge Behaviors in Multi-Stage and Single-Stage Axial Flow Compressors

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.4
    • /
    • pp.338-353
    • /
    • 2016
  • Information on the surge behaviors and stall stagnation boundaries for a nine-stage axial flow compressor are summarized on the basis of analytical data in comparison with those for a single-stage one, with attention to the pressure ratio effect. The general trends of the surge loop behaviors of the pressure-mass flow are similar for both compressors including the fact that the subharmonic surges tend to appear very near the stall stagnation boundaries. With respect to the nine-stage compressor, however, the mild loops in the subharmonic surges tend to be very small in size relative to the deep loops, and at the same time, insufficient surge recovery phenomenon, which is a kind of subharmonic surge, appears also far from the stagnation boundary for relatively short delivery flow-paths. The latter is found to be a rear-stage surge caused by unstalling and re-stalling of the rear stages with the front-stages kept in stall in the stalled condition of the whole compressor, which situation is caused by stage-wise mismatching in the bottom pressure levels of the in-stall multi-stage compressor. The fundamental information on the stall stagnation boundaries is given by a group of normalized geometrical parameters including relative delivery flow-path length, relative suction flow-path length, and sectional area-pressure ratio, and by another group of normalized frequency parameters including relative surge frequencies, modified reduced resonance frequencies, and modified reduced surge frequencies. Respective groups of the normalized parameters show very similar tendency of behaviors for the nine-stage compressor and the single-stage compressor. The modified reduced resonance frequency could be the more reasonable parameter suggesting the flow-induced oscillation nature of the surge phenomena. It could give the stall stagnation boundary in a more unified manner than the Greitzer's B parameter.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

A Study on the Operational Characteristic with the Scale Effect of the Cross-Flow Fan (치수효과를 고려한 횡류홴의 작동특성연구)

  • Kim, H.-S.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.583-589
    • /
    • 2004
  • One of noticeable features in the cross flow fan is that a working fluid passes through impeller blade twice without distinction between the inlet and exit angles. Also, it does produce higher circumferential velocity than other types of blade at the same flow rate in accordance with the application of the forward curved shape. However, a design theory for the cross-flow fan has not yet been formed owing to an eccentric vortex, which is the remarkable characteristics, occurred in a cross-flow fan. Furthermore, the eccentric vortex, which is difficult to control of the size and position, is the important cause of performance decrease. In this study, experiments are carried out to estimate the similarity of the cross-flow fan with various scales and rotational velocity changes. Pressure coefficients to flow coefficients with various scales of the cross-flow fan are plotted to research the application of the general similarity law of the turbomachinery in the cross-flow fan with Archimedes spital, which is the important factor haying an effect on it.

  • PDF

Drag Reduction of Cylinder with Dimpled Surface (표면에 딤블이 있는 원주의 항력감소)

  • 노기덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2001
  • Fundamental studies on the drag reduction of the circular cylinder having dimple were conducted by the measurement of the fluid force acting on the cylinder and by the flow visualization around the cylinder. The drag coefficients were changed by the shape and the geometrical arrangement of the dimple. The drag of the cylinder was reduced about 25% by the proper arrangement of the dimple. The flow field around the cylinder having dimple, which was the minimum drag, was visualized by the hydrogen bubble technique. In this case, the separation points were moved rearward and the wake region was small in comparison with that of the cylinder having no dimple.

  • PDF

Influence of a weak superposed centripetal flow in a rotor-stator system for several pre-swirl ratios

  • Nour, Fadi Abdel;Rinaldi, Andrea;Debuchy, Roger;Bois, Gerard
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.2
    • /
    • pp.49-59
    • /
    • 2012
  • The present study is devoted to the influence of a superposed radial inflow in a rotor-stator cavity with a peripheral opening. The flow regime is turbulent, the two boundary layers being separated by a core region. An original theoretical solution is obtained for the core region, explaining the reason why a weak radial inflow has no major influence near the periphery of the cavity but strongly affects the flow behavior near the axis. The validity of the theory is tested with the help of a new set of experimental data including the radial and tangential mean velocity components, as well as three components of the Reynolds stress tensor measured by hot-wire anemometry. The theoretical results are also in good agreement with numerical results obtained with the Fluent code and experimental data from the literature.