• Title/Summary/Keyword: fluence

Search Result 379, Processing Time 0.023 seconds

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

Etching of the PDP barrier rib material using laser beam (레이저빔에 의한 PDP 격벽 재료의 식각)

  • Ahn, Min-Young;Lee, Kyoung-Cheol;Lee, Hong-Kyu;Lee, Sang-Don;Lee, Cheon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.526-532
    • /
    • 2000
  • The paste on the glass or fabrication of the PDP(Plasma Display Panel) barrier rib was selectively etched using focused A $r_{+}$ laser(λ=514 nm) and Nd:YAG(λ=532, 266 nm) laser irradiation. The depth of the etched grooves increase with increasing a laser fluence and decreasing a laser beam scan speed. Using second harmonic of Nd:YAG laser(532 nm) the etching threshold laser fluence was 6.5 mJ/c $m^2$ for the sample of PDP barrier rib. The thickness of 180 ${\mu}{\textrm}{m}$ of the sample on the glass was clearly removed without any damage on the glass substrate by fluence of 19.5J/c $m^2$beam scan speed of 20${\mu}{\textrm}{m}$ /s. In order to increase the etch rate of the barrier rib material barrier rib samples heated by a resistive heater during laser irradiation. The heated sample has many defects and becomes to be fragile. This imperfection of the structure compared to the sample without heat treatment allows the effective etching by the focused laser beam. The etch rates were 65${\mu}{\textrm}{m}$/s and 270 ${\mu}{\textrm}{m}$/s at room temperature and 20$0^{\circ}C$, respectively.y.

  • PDF

Experimental Investigation for Ablation Characteristics of Polyimide Layer and Cu-metal Layer using High Power Nd:YAG UV Laser (고출력 Nd:YAG UV레이저를 이용한 polyimide층과 Cu-metal층의 가공상태에 대한 실험적 고찰)

  • Choi, Kyung-Jin;Lee, Young-Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • In this paper, the laser cutting characteristics of the flexible PCB using high power Nd:YAG UV laser were investigated. A specific FPCB model was selected for the experiment. Test sheets were made, which had equal materials and layer structure to those of the outline (OL) region and the contact pad (CP) region in the FPCB. The experiment is made up of two stages. In the first stage of the experiment, the laser cutting fluence was found, which is the threshold fluence to cut the test sheets completely. The laser cutting fluence of the OL sheet is $1781.26{\sim}1970.16\;J/cm^2$ and that of the CP sheet is $2109.34{\sim}2134.34\;J/cm^2$. In the second stage, cutting performance and its qualities were analyzed by the experiment. The laser cutting performance remained almost unchanged for all laser and process parameter sets. The average cutting width (top side/bottom side) of the OL sheet was $40.45\;{\mu}m/11.52\;{\mu}m$ and that of the CP sheet was $22.14\;{\mu}m/10.93\;{\mu}m$. However, the laser cutting qualities were different according to the parameters. The adjacent region of the cutting line on the OL sheet was carbonized as the beam speed was low and the overlap coefficient was high. The surface quality around the cutting line of the CP sheet was about the same. Carbonization and debris occurred on the surface of the cutting line. As a result of the experiment, the cutting qualities were better as the overlap coefficient was made low and beam speed high. Therefore, the overlap coefficient 2 or 3 is proper for the FPCB laser cutting.

  • PDF

Quantitative Analysis and Comparison of DR and CR image quality (CR과 DR 영상화질의 정량적 비교분석)

  • Park, Hey-Suk;Seo, Jang-Yeon;Jeong, Jin-Hwa;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • The purpose of this research was to compare and analyze image quality for each Detector of CR(Computed Radiography) and DR(Digital Radiography). The results showed that CR(AGFA MD 4.0 General plate, JAPAN) was superior to DR(HOLOGIC nDirect Ray, USA) based on the quantitative values and comparison of MTF(Modulation Transfer Function), NPS(Noise Power Spectrum), Photon fluence and DQE(Detective Quantum Efficiency) which have been widely accepted for the estimation of CR and DR. Quantitative evaluations of CR and DR system were obtained and they may be very helpful for QA and QC of general X-ray systems.

  • PDF

Measuring the Light Dosimetry Within Biological Tissue Using Monte Carlo Simulation (Monte Csrlo 시뮬레이션을 이용한 생체조직내의 광선량 측정)

  • 임현수;구철희
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 1999
  • As the correct measuring of the light dosimetry in biological tissues give the important affection to the effect of PDT treatment we used Monte Carlo simulation to measure the light dosimetry on this study. The parameters using in experiments are the optical properties of the real biological tissue, and we used Henyey-Greenstein phase function among the phase functions. As we results, we displayed the result the change of Fluence rate and the difference against the previous theory was at least 0.35%. Biological tissues using in experiment were Human tissue, pig tissue, rat liver tissue and rabbit muscle tissue. The most of biological tissue have big scattering coefficient in visible wavelength which influences penetration depth. The penetration depth of human tissue in visible region is 1.5~2cm. We showed that it is possible to measure fluence rate and penetration depth within the biological tissues by Monte Carlo simulation very well.

  • PDF

Tailoring the properties of spray deposited V2O5 thin films using swift heavy ion beam irradiation

  • Rathika, R.;Kovendhan, M.;Joseph, D. Paul;Pachaiappan, Rekha;Kumar, A. Sendil;Vijayarangamuthu, K.;Venkateswaran, C.;Asokan, K.;Jeyakumar, S. Johnson
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2585-2593
    • /
    • 2020
  • Swift heavy ion (SHI) beam irradiation can generate desirable defects in materials by transferring sufficient energy to the lattice that favours huge possibilities in tailoring of materials. The effect of Ag15+ ion irradiation with energy 200 MeV on spray deposited V2O5 thin films of thickness 253 nm is studied at various ion doses from 5 × 1011 to 1 × 1013 ions/㎠. The XRD results of pristine film confirmed orthorhombic structure of V2O5 and its average crystallite size was found to be 20 nm. The peak at 394 cm-1 in Raman spectra confirmed O-V-O bonding of V2O5, whereas 917 cm-1 arise because of distortion in stoichiometry by a loss of oxygen atoms. Raman peaks vanished completely above the ion fluence of 5 × 1012 ions/㎠. Optical studies by UV-Vis spectroscopy shows decrement in transmittance with an increase in ion fluence up to 5 × 1012 ions/㎠. The red shift is observed both in the direct and indirect band gaps until 5 × 1012 ions/㎠. The surface topography of the pristine film revealed sheath like structure with randomly distributed spherical nano-particles. The roughness of film decreased and the density of spherical nanoparticles increased upon irradiation. Irradiation improved the conductivity significantly for fluence 5 × 1011 ions/㎠ due to band gap reduction and grain growth.

Comparison of Iron(Fe) Data of ENDF/B-IV and VI in Yonggwang Nuclear Unit-3/4 Vessel Fluence Calculation (영광 3/4호기 압력용기의 중성자 조사량계산을 통한 ENDF / B-IV와 VI 철(Fe) 자료의 비교)

  • Kim, Tae-Hyeong;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.74-83
    • /
    • 1995
  • The accurate determination of the fast neutron flux/fluence onto the pressure vessel is an essential part of the reactor pressure vessel surveillance program. It has been reported recently that the iron cross section data in ENDF/B versions III through V might underestimate the flux/fluence of fast neutrons in steel structures such as reactor pressure vessel. In this study, for the comparison of iron data of ENDF/B-IV and VI we produced two 47-group cross section sets, CXFe-IV and CXFe-Ⅵ, which are based on Yonggwang nuclear unit-3/4 model and the iron data of ENDF/B-IV and VI, respectively. A comparison was made of the results obtained from DOT4.3 calculation using CXFe-IV and CXFe-VI. From the results, it was found that the fast flux(E 〉 1.0 MeV), which is important for the pressure vessel embrittlement analysis, increases by about 7.6% at the inner wall and 20% at the outer wall of the vessel, if the iron data are used from ENDF/B-VI instead of ENDF/B-IV.

  • PDF

Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

  • Lee, Gyeong-Geun;Kim, Min-Chul;Yoon, Ji-Hyun;Lee, Bong-Sang;Lim, Sangyeob;Kwon, Junhyun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.760-768
    • /
    • 2017
  • The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant's lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

Optical Properties of Proton-irradiated Polyacrylonitrile Film (양성자 조사된 폴리아크릴로니트릴 필름의 광학적 특성)

  • Lee, Hwa-Su;Baek, Ga-Young;Jung, Jin-Mook;Hwang, In-Tae;Jung, Chan-Hee;Shin, Junhwa;Choi, Jae-Hak
    • Journal of Radiation Industry
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • In this study, the effect of high-energy proton irradiation on the optical properties of polyacrylonitrile (PAN) films was investigated. PAN thin films spin-coated on a substrate were irradiated 150 keV proton ions at various fluences. The changes in the chemical structure and optical properties were investigated by FT-IR and UV-vis spectroscopy. The results of the FT-IR analysis revealed that the cyclization reaction took place by proton irradiation and the degree of cyclization increased with an increasing fluence. Based on the UV-vis analysis, the optical band gap of PAN decreased from 2.84 to 2.52 eV with an increasing fluence due to the formation of carbon clusters by proton irradiation. In addition, the number of carbon atoms per carbon cluster and the number of carbon atoms per conjugation length were found to be increased with an increasing fluence.

Effectiveness of the Pico-toning Technique for the Treatment of Melasma with a Low Fluence 1,064-nm Nd:YAG Laser in Asian Patients

  • Kim, Dong Gyu;Nam, Seung Min;Shin, Jin Soo;Park, Eun Soo
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.166-171
    • /
    • 2020
  • Background and Objectives Melasma is an acquired pigmentary disorder characterized by brown or dark brown colored macules and patches which mostly involve the face. Compared to nanosecond lasers, picosecond lasers have fewer adverse effects on surrounding tissues and give better results for melanin fragmentation. The purpose of this study was to evaluate the efficacy of the pico-toning technique using a low fluence 1,064-nm Nd:YAG laser on melasma patients. Materials and Methods This study is a retrospective analysis of melasma cases treated using the pico-toning technique from June 2017 to November 2020. Based on photographic images, the modified Melasma Area and Severity Index (mMASI) score was blind evaluated by two independent plastic surgeons. Patient satisfaction was assessed through a 5-point Likert scale questionnaire after treatment sessions. All adverse effects and complications were reviewed based on medical records. Results A total of 23 patients were included in the study. The mMASI scores for baseline and 2 months after the last procedure were 5.1 ± 1.4 and 2.6 ± 0.4, respectively. The mean mMASI score reduced significantly after the treatment session (p < 0.05). The patient satisfaction score with the procedure was 3.8 ± 1.0. The subject satisfaction score and difference in the mMASI score before the procedure and 2 months after the last procedure showed a significant correlation. Adverse effects observed in this study were erythema (n = 1) and edema (n = 1). Conclusion The results of the study show that the pico-toning technique is effective in Asian patients with melasma. We believe that safety was enhanced by using low fluence, and thus better results were achieved with fewer adverse effects.