• Title/Summary/Keyword: fluence

Search Result 379, Processing Time 0.027 seconds

A Note on Factors of Mathematical Creativity Assessment through Problem Posing (문제설정에서의 수학적 창의성 평가 요소에 대한 소고)

  • Kim, PanSoo
    • Journal of Gifted/Talented Education
    • /
    • v.24 no.6
    • /
    • pp.1053-1071
    • /
    • 2014
  • Problem posing is used to develop the creativity program and adaption for the gifted, and to screen the gifted students in the selection process. However existing creativity assessment factors(fluence, flexibility, originality) has been recognized to have it's limitation to assess the mathematical creativity. To improve the creativity assessment, we propose new set of assessment factors for mathematical creativity test through problem posing. For this study, we let 19 mathematically gifted students to pose two good mathematical problems for a limited time after solving a certain problem so called a reference problem. A week late, we let the subjects, pre-service teachers, and experts to evaluate the problems posed by the subjects, and leave the reasons for evaluating highest mark and lowest mark. With this date, we propose fluence, flexibility, originality, anti-similarity, complexity, elaboration as the set of mathematics creativity assessment factors.

Ablation rate study using short pulsed laser subjected to Alumina medium (알루미나 세라믹 소재의 초단파 레이저 어블레이션량 연구)

  • Kim, Kyunghan;Park, Jinho
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.17-22
    • /
    • 2015
  • In this paper, ablation rate of $Al_2O_3$ ceramics by femtosecond laser fluence is derived with experimental method. The automatic three axis linear stage makes laser optics to move with high spatial resolution. With 10 times objective lens, minimal pattern width of $Al_2O_3$ is measured in the focal plane. Ablated surface area is shown as linear tendency increasing number of machining times with various laser power conditions. Machining times is most sensitive condition to control $Al_2O_3$ pattern width. Also, the linear increment of pattern width with laser power change is investigated. In high machining speed, the ablation volume rate is more linear with fluence because pulse overlap is minimized in this condition. Thermal effect to surrounding medium can be minimized and clean laser process without melting zone is possible in high machining speed. Ablation volume rate decelerates as increasing machining times and multiple machining times should be considered to achieve proper ablation width and depth.

Reduction of Vacuum Sublimation by Ion Beam Treatment for e-beam Deposited SiC Films

  • Kim, Jaeun;Hong, Sungdeok;Kim, Yongwan;Park, Jaewon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.138.1-138.1
    • /
    • 2013
  • We present the low temperature (${\leq}1,000^{\circ}C$) vacuum sublimation behavior of an e-beam evaporative deposited on a SiC film and a method to reduce the vacuum sublimation through an ion beam process. The density of the SiC film deposited using the e-beam evaporation method was ~60% of the density of the bulk source material. We found that the sublimation became appreciable above ${\sim}750^{\circ}C$ under $1.5{\times}10^{-5}$ torr pressure and the sublimation rate increased with an increase in temperature, reaching ~70 nm/h at $950^{\circ}C$ when the coated sample was heated for 5 h. When the film was irradiated with 70 keV N+ ions prior to heating, the sublimation rate decreased to ~23 nm/h at a fluence of $1{\times}10^{17}\;ions/cm^2$. However, a further increase in fluence beyond this value or an extended heating period did not change (decrease or increase) the sublimation rate any further.

  • PDF

Time-resolved transient reflective image on silicon surface after single-shot fs-laser pulse irradiation (단일 펨토초 레이저펄스를 이용한 실리콘 표면에서의 시분해 반사율 측정 연구)

  • Moon, Heh-Young;Sidhu, Mehra Singh;Lee, Hyun-Kyu;Jeoung, Sae-Chae
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • In this work, we have studied on time-resolved transient reflective image of single crystalline Si surface after single-shot fs-laser irradiation with varying the laser fluence under two different laser spot sizes. The temporal profiles of transient reflectivity changes as well as its maximum values at the early delay time were found to be strongly dependent on both the laser beam spot size and laser fluence. We have interpreted the dependence of transient reflectivity changes on the laser spot size in terms of a relaxation of the generated free carriers to the bulk silicon, which should be interacted with the plasma.

  • PDF

Deposition of Ferroelectric PB(Zr0.52Ti0.48)O3 Films on Platinized Silicon Using Nd:YAG Laser

  • Im, Hoong-Sun;Kim, Sang-Hyeob;Choi, Young-Ku;Lee, Kee-Hag;Jung, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.56-61
    • /
    • 1997
  • Lead zirconate titanate (PZT) thin fills were deposited onto the Pt/Ti/SiO2/Si substrate by the pulsed laser deposition with the second harmonic wavelength (532 nm) of Nd:YAG laser. In order to determine the optimum conditions for the film deposition, the phase of the films were investigated as functions of ambient oxygen pressure, substrate temperature, and laser fluence. Also the chemical composition analysis was conducted for the PZT films deposited under various ambient oxygen pressure. When the distance between substrate and bulk PZT target is set to 20 mm, the optimum conditions have been determined to be 3 torr of oxygen pressure, 1.5 J/cm2 of laser fluence, and 823-848(±10) K range of substrate temperature. At these conditions, perovskite phase PZT films were obtained on platinized silicon. The chemical composition of the films is very similar to that of PZT bulk target. The physical structure of the deposited films analyzed by scanning electron microscopy shows a columnar morphology perpendicular to the substrate surface. Capacitance-Voltage hysteresis loop measurements show also a typical characteristics of ferroelectric thin film. The dielectric constant is found to be 528 for the 0.48 μm thickness of PZT thin film.

Statistical Evaluation of Factors Affecting IASCC of Austenitic Stainless Steels for PWR Core Internals (오스테나이트계 스테인리스강 노내 구조물의 조사유기응력부식균열 영향 인자에 대한 통계적 분석)

  • Kim, Sung-Woo;Hwang, Seong-Sik;Kim, Hong-Pyo
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.819-827
    • /
    • 2009
  • This work is concerned with a statistical analysis of factors affecting the irradiation-assisted stress corrosion cracking (IASCC) of austenitic stainless steels for core internals of pressurized water reactors (PWR). The microstructural and environmental factors were reviewed and critically evaluated by the statistical analysis. The Cr depletion at grain boundary was determined to have no significant correlation with the IASCC susceptibility. The threshold irradiation fluence of IASCC in a PWR was statistically calculated to decrease from 5.799 to 1.914 DPA with increase of temperature from 320 to $340^{\circ}C$. From the analysis of the relationship between applied stress and time-to-failure of stainless steel components based on an accelerated life testing model, it was found that B2 life of a baffle former bolt exposed to neutron fluence of 20 and 75 DPA was at least 2.5 and 0.4 year, respectively, within 95% confidence interval.

Development of long-term irradiation testing technology at HANARO

  • Choo, Kee Nam;Yang, Seong Woo;Park, Seng Jae;Shin, Yoon Taeg
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.344-350
    • /
    • 2021
  • As the High Flux Advanced Neutron Application Reactor (HANARO) has been recently required to support new R&D relevant to future nuclear systems requiring a much higher neutron fluence, the development of irradiation capsule technology for long-term irradiation testing was performed in three steps (3, 5, 10 dpa). At first, several design improvements of a standard capsule were suggested based on a failure analysis of the capsule and successfully applied for irradiation testing at HANARO at up to eight reactor operation cycles equivalent to 3 dpa. Based on a schematic stress analysis of the vulnerable parts of the previous capsule, an optimized design of the capsule was made for 5 dpa irradiation. The newly designed capsule was safely out-pile tested up to 450 days, which was equivalent to 5 dpa irradiation in the reactor. The test results were submitted to the Reactor Safety Review Committee of HANARO and irradiation testing for 5 dpa was approved. The capsule was also successfully out-pile tested to evaluate the possibility of irradiation testing for 10 dpa. For a higher neutron fluence exceeding 10 dpa, new capsule technologies, including a new capsule that has a different bottom design and neutron flux boosting capsule, were also suggested.

Radiation damage analysis in SiC microstructure by transmission electron microscopy

  • Idris, Mohd Idzat;Yoshida, Katsumi;Yano, Toyohiko
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.991-996
    • /
    • 2022
  • Microstructures of monolithic high purity SiC and SiC with sintering additives after neutron irradiation to a fluence of 2.0-2.5 × 1024 n/m2 (E > 0.1 MeV) at 333-363 K and after post-irradiation annealing up to 1673 K were observed using a transmission electron microscopy. Results showed that no black spot defects or dislocation loops in SiC grains were found after the neutron irradiation for all of the specimens owing to the moderate fluence at low irradiation temperature. Thus, it is confirmed that these specimens were swelled mostly by the formation of point defects. Black spots and small dislocation loops were discovered only after the annealing process in PureBeta-SiC and CVD-SiC, where the swelling almost diminished. Anomalous-shaped YAG grains were found in SiC ceramics containing sintering additives. These grains contained dense black spots defects and might lose crystallinity after the neutron irradiation, while these defects may annihilate by recrystallization during annealing up to 1673 K. Amorphous grain boundary phase was also presented in this ceramic, and a large part of it was crystallized through post-irradiation annealing and could affect their recovery behavior.

The Dependence of the Wedge Factor with the Variation of High Energy Photon Beam Fluences (고에너지 광자선의 선속 변화에 따른 쐬기인자의 의존성)

  • 오영기;윤상모;김재철;박인규;김성규
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2000
  • For wedged photon beams, the variation of the wedge factor with field size was reported by several authors. However, until now such variation with field size had not been explained quantitatively. Therefore, the variation of the wedge factor was investigated by measuring outputs with field sizes increasing from 4 cm $\times$ 4 cm to 25 cm $\times$ 25 cm for open and wedged 6 and 10MV X-ray beams. The relative outputs for wedged fields to 10 cm $\times$ 10 cm have been obtained. The results show the Increase of the wedge factor caused by the change in fluence of high energy Photon beam with field size, up to 8.0% for KD77-6MV X-ray beam. This increase could be explained as a linear function of the irradiated wedge volume except small field size up to about 10 cm. In the cases of the narrow rectangular beam parallel to the wedge direction, the wedge factor decreases slightly with increasing field size up to about 10-15 cm due to a relatively reduced photon fluence from the change of the wedge thickness. We could explain the causes of a wedge factor variation with field size as the fluences of primary photon passed throughout the wedge, contributing to the dose at the central beam axis and that the fluences were affected by the gradient of the wedge with the change of field size. For clinical use, the formula developed to describe the wedge factor variation with field size has been corrected.

  • PDF

Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example (GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법)

  • Kim, Byung-Yong;Kim, Hyung-Dong;Kim, Sung-Jin;Oh, Se-An;Kang, Jung-Gu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.