• Title/Summary/Keyword: flowing resistance

Search Result 120, Processing Time 0.029 seconds

Constructal study on optimizing the pressure drop of the flow channel configurations with two diameters (형상법칙을 이용한 트리구조의 압력강하 최적화 연구)

  • Cho, Kee-Hyeon;Lee, Jae-Dal;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2652-2657
    • /
    • 2008
  • An analytical study was carried out on the flow resistance of tree-shaped channel flow architectures, based on the principle of the constructal law of evolutionary increase of flow access through the generation of better flowing configurations with two diameters in the square domain. Two types of tree-shaped configurations are optimized. The minimized global flow resistance decreases definitely as the system size, N, increases. And the best channel configurations among the first construct and second construct as a result of regarding pressure drop was selected. We also show that the freedom to morph the design and to increase its performance can be enhanced by using tree-tree configurations with $2^{nd}$ construct when N is greater than 18.

  • PDF

A Study on the Design of the Stern Stow Net (선미식 안강망 어구의 설계에 관한 연구)

  • 김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.4
    • /
    • pp.343-352
    • /
    • 1999
  • Because stow net being used in now is doing throwing net and hauling net through a ship's side, the work is very complicated and the fishing boat needs many seamen and it could cause a loss of lives and ship in stormy weather. We are now using small mesh size 36~500mm and it even catches young fish, so we call it the fishing gear of resource reduction type.Therefore we must make manpower reduction in automatic operation, safe operation of throwing net and hauling net in the stern and the stern-typed stow net of resource management using large mesh. And we performed three-typed model tests to examine the fishing gear. The obtained results are as follows;1. The fishing gear being used in the ship's side type stow net has inappropriate standard and arrangement of the net, resistance increase of the fishing gear and frequent breakdown of the net.2. To supplement the fault of A-typed stow net, we schemed fishing gear developed as both B-type(12-seamed net) and C-types(8-seamed net) of the stern-typed stow net. 3. In model tests, C-typed model net(mesh size 40~1,600mm) was proved good fishing gear because the resistance in accordance with the flowing speed was comparatively small and it's mouth area was broad. 4. A-typed stow net had the spreading device attached to side panel of the net, but the stern-typed stow net had the spreading device consisted of 4 lines far behind about 6m from side panel of the net mouth. In the flowing speed 2knot, the spreading condition of fishing gear was proved batter than the former.

  • PDF

Effect of Cr Addition to High Mn Steel on Flow-Accelerated Corrosion Behaviors in Neutral Aqueous Environments (Cr 첨가가 고망간강의 중성 수용액 환경 내 유동가속부식 거동에 미치는 영향)

  • Jeong, Yeong Jae;Park, Jin Sung;Bang, Hye Rin;Lee, Soon Gi;Choi, Jong Kyo;Kim, Sung Jin
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.373-383
    • /
    • 2021
  • The effect of Cr addition to high Mn steel on flow-accelerated corrosion (FAC) behavior in a neutral aqueous environment was evaluated. For comparison, two types of conventional ferritic steels (API X70 steel and 9% Ni steel) were used. A range of experiments (electrochemical polarization and impedance tests, weight loss measurement, and metallographic observation of corrosion scale) were conducted. This study showed that high Mn steel with 3% Cr exhibited the highest resistance to FAC presumably due to the formation of a bi-layer scale structure composed of an inner Cr enriched Fe oxide and an outer Mn substituted partially with Fe oxide on the surface. Although the high Mn steels had the lowest corrosion resistance at the initial corrosion stage due to rapid dissolution kinetics of Mn elements on their surface, the kinetics of inner scale (i.e. Cr enriched Fe oxide) formation on Cr-bearing high Mn steel was faster in dynamic flowing condition compared to stagnant condition. On the other hand, the corrosion scales formed on API X70 and 9% Ni steels did not provide sufficient anti-corrosion function during the prolonged exposure to dynamic flowing conditions.

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.

Erosion Characteristics of Kaolinite with respect to Contents of Silt (실트함량에 따른 카올리나이트의 침식특성 평가)

  • Lee, Ju-Hyung;Park, Jae-Hyun;Chung, Mun-Kyung;Kwak, Ki-Seok
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.593-596
    • /
    • 2008
  • The scour phenomenon involves the erosive potential of flowing water and the relative ability of the soil to resist erosion. The scour phenomenon in cohesive soils is much different from that in non-cohesive soils. Granular soils resist erosion by their buoyant weight and the friction between the particles. The soil particles are dislodged individually from the bed under the action of the eroding fluid. Scour in cohesive soils is much slower and more dependent on soil properties than that in non-cohesive soils. Therefore the analysis models for estimating erosion characteristics of cohesive soils should consider not only flowing water but also the relative ability of the soil to resist erosion. In this study, erosion characteristics for the clay-silt mixed soil will be analyzed as a fundamental study for development of bridge scour analysis and design system considering scour resistance capacity of a soil. For this analysis, the relationship between scour characteristics and soil properties was evaluated through scour rate test with Kaolinite samples remolded using various loading and contents of silt.

  • PDF

Network Modeling on Track Circuit and Analysis of Resistance Characteristic on Wood Sleeper (궤도회로의 단자망 모델링 및 목침목 저항 특성 해석)

  • Yoon, In-Mo;Kim, Min-Seok;Ko, Young-Hwan;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.6
    • /
    • pp.565-569
    • /
    • 2010
  • Sleepers perform bearing rails and are underneath rails. Therefore, the current and voltage of rails are related to the resistance of sleepers. In case that the resistance of sleepers are low, operation problems of relays in tr ack circuits are occur because of flowing leakage current through sleepers. So the condition that the track circuit is always occupied by a train is kept. Currently, the creosote has been used in wood sleepers due to prevention against putrefaction. After a long time, the material is changeable to the chemistry material bases on carbon dioxide or carbon. So, the insulation resistance of wood sleepers is lower than the initial insulation resistance. In case of effecting wood sleepers as conductors, amplitude of the current and voltage on rails is decreased. This phenomenon causes that a train does not receive signals. In this paper, four-network model on the track circuit including the insulation resistance of sleepers is suggested. Also, the standard value of the resistance in straight section is proposed in the wood sleeper.

High Frequency Grounding Impedances of Vertically-Driven Ground Rods

  • Kim, Tae-Ki;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.41-48
    • /
    • 2009
  • Grounding impedance depends on the frequency of current flowing into a grounding system lightning in particular has a broad frequency spectrum from some tens of Hz to a few MHz. So the grounding impedance related to transient currents such as lightning should be measured. In this paper, the grounding impedances of vertically-driven ground rods of 10, 30 and 48[m] long are measured and analyzed as functions of the frequency of injected current and the feeding point. As a result, the longer the ground rod is, the lower the steady-state ground resistance is. However the grounding impedance of a vertically-driven ground rod at a high frequency is significantly increased. It is not always true that low grounding impedance follows from a low steady-state ground resistance. It is important to evaluate the high frequency performance of grounding systems for protection against lightning.

Surface erosion behavior of biopolymer-treated river sand

  • Kwon, Yeong-Man;Cho, Gye-Chun;Chung, Moon-Kyung;Chang, Ilhan
    • Geomechanics and Engineering
    • /
    • v.25 no.1
    • /
    • pp.49-58
    • /
    • 2021
  • The resistance of soil to the tractive force of flowing water is one of the essential parameters for the stability of the soil when directly exposed to the movement of water such as in rivers and ocean beds. Biopolymers, which are new to sustainable geotechnical engineering practices, are known to enhance the mechanical properties of soil. This study addresses the surface erosion resistance of river-sand treated with several biopolymers that originated from micro-organisms, plants, and dairy products. We used a state-of-the-art erosion function apparatus with P-wave reflection monitoring. Experimental results have shown that biopolymers significantly improve the erosion resistance of soil surfaces. Specifically, the critical shear stress (i.e., the minimum shear stress needed to detach individual soil grains) of biopolymer-treated soils increased by 2 to 500 times. The erodibility coefficient (i.e., the rate of increase in erodibility as the shear stress increases) decreased following biopolymer treatment from 1 × 10-2 to 1 × 10-6 times compared to that of untreated river-sands. The scour prediction calculated using the SRICOS-EFA program has shown that a height of 14 m of an untreated surface is eroded during the ten years flow of the Nakdong River, while biopolymer treatment reduced this height to less than 2.5 m. The result of this study has demonstrated the possibility of cross-linked biopolymers for river-bed stabilization agents.

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

Preparation and Curing Behavior of Polyurethane Coatings by Polyester/Lactone Polyol and HDI-biuret (폴리에스테르/락톤 폴리올과 HDI-Biuret에 의한 폴리우레탄 도료의 제조 및 경화거동)

  • 최용호;김대원;황규현;박홍수;김태옥
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.72-81
    • /
    • 2000
  • Benzoic acid polyester/lactone polyol were synthesized by polycaprolactone 0201 as diol, trimethylolpropane as triol, adipic acid as dibasic acid, and benzoic acid as monobasic acid. Polyisocyanate prepolymer Desmodur N-100 of HDI-biuret type was used in this study. Two-component polyurethane coatings were prepared by blending benzoic acid polyester/polycaprolactone, polyisocyanate, wetting/dispersing agent, white pigment, and flowing agent. Various properties were examined on the film coated with the prepared polyurethane. They showed excellent physical properties such as abrasion resistance, accelerated weathering resistance, and yellowness index. They also showed good physical properties such as flexibility, impact resistance, 60$^{\circ}$ specular gloss, cross hatch adhesion, hydrocarbon resistance, and lightness index difference. Hardness of coating showed a little poor character. The introduction of polycaprolactone 0201 as diol in the polyurethane coatings improved the hydrocarbon resistance, impact resistance, and flexibility of coatings. According to the drying and curing behavior with the contents of benzoic acid, they seem to have reasonable coating properties such as drying time of 2 to 4 hours and pot-life time of 20 to 37 hours.

  • PDF