• Title/Summary/Keyword: flowing resistance

Search Result 120, Processing Time 0.023 seconds

Electrochemical Evaluation of Corrosion Property of Welded Zone of Seawater Pipe by DC Shielded Metal Arc Welding with Types of Electrodes (선박 해수배관에서 용접봉의 종류에 따라 직류 아크 용접한 용접부위의 부식특성에 관한 전기화학적 평가)

  • Lee, Sung-Yul;Lee, Kyu-Hwan;Won, Chang-Uk;Na, Shane;Yoon, Young-Gon;Lee, Myeong-Hoon;Kim, Yun-Hae;Moon, Kyung-Man;Kim, Jin-Gyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.79-84
    • /
    • 2013
  • The seawater pipes in the engine rooms of ships are surrounded by severely corrosive environments caused by fast flowing seawater containing chloride ions, high conductivity, etc. Therefore, it has been reported that seawater leakage often occurs at a seawater pipe because of local corrosion. In addition, the leakage area is usually welded using shielded metal arc welding with various electrodes. In this study, when seawater pipes were welded with four types of electrodes(E4311, E4301, E4313, and E4316), the difference between the corrosion resistance values in their welding zones was investigated using an electrochemical method. Although the corrosion potential of a weld metal zone welded with the E4316 electrode showed the lowest value compared to the other electrodes, its corrosion resistance exhibited the best value compared to the other electrodes. In addition, a heat affected zone welded with the E4316 electrode also appeared to have the best corrosion resistance among the electrodes. Furthermore, the corrosion resistance of the weld metal zone and heat affected zone exhibited relatively better properties than that of the base metal zone in all of the cases welded with the four types of electrodes. Furthermore, the hardness values of all the weld metal zones were higher than the base metal zone.

Study of the Tidal Discharge (조석출입량에 관한 조사)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1394-1408
    • /
    • 1968
  • The tidal discharge is defined as the quantity of water flowing through a certain cross-section per unit of time, in contrast to river discharges, tidal discharges change periodically in magnitude and direction. Thus the total volumes of water flowing into again out of the system-called flood volume and ebb volume, respectively, depend on both the tidal and the river discharges. To ditermine the tidal discharge and the flood and ebb volumes of the Yong-san river, the discharges were measured at spring, mean and neap tide and simultaneous gage reading were taken at Samhak-do, Lower Myo-do, Myongsan-ni and Naju. The general procedure for measuring the tidal discharges was as follows. First, several cross-sections were measured and one of them was chosen. First, several cross-sections were measured and one of them was chosen. Then verticals were serected in the chosen cross section. Because comparatively few verticals should be representative of the discharge distribution over the river profile, the selection was done in accordance with the somtimes irregular bottom profile. The velocities were measured with the same current meters. The observations which included water level readings were continued for a period of about 13 hours. The current direction meter, a pyramid shaped resistance body, suspend in the water on a thin wire. The bubble in a circular tilting level fixed to the wire indicates the direction of the current. Reading were taken at intervals of 1m for depths of 10m or less, and for depths over 10m at intervals of 2m, going downwards and upwards. The averages of the two velocities were used for the computation of the discharges. The discharges and the flood and ebb volumes were ditermined by a graphical method. The mean velocities, corrected for their direction when necesary, were ditermined for each time interval and each vertical, and these velocities were plotted against the time. The resulting curves show possible mistakes very clearly, and the effect of observation errors could be reduced. The corrected velocities read from the curve at half-hour intervals were multiplied by the depth at the virtical at the corresponding time. The discharges thus found were ploted against the position of the vertical in the transit and joined by a smooth curve, integration of the curve rendered the total discharges as they occurred of half-hour intervals. Plotting these total discharges against the time yeilded during the day. The flood and ebb volumes were obtained by integration of the total discharge curve.

  • PDF

Evaluation of the corrosion property on the welded zone of seawater pipe by A.C shielded metal arc welding (교류 피복아크 용접에 의한 해수 배관 용접부위의 부식 특성 평가)

  • Jeong, Jae-Hyun;Kim, Yun-Hae;Moon, Kyung-Man;Lee, Myeong-Hoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.877-885
    • /
    • 2013
  • A seawater pipe of the engine room in the ships is being surrounded with severely corrosive environments caused by fast flowing of the seawater, containing aggressive chloride ion and high conductivity etc.. Therefore, the leakage of the seawater from its pipe have been often occurred due to its local corrosion by aggressive chloride ions. Subsequently, its leakage area is usually welded by AC shielded metal arc welding with various electrodes. In this study, when the sea water pipe is welded with several types of electrodes such as E4301, E4311, E4313 and E4316, a difference of the corrosion resistance on the welding metal zones was investigated using an electrochemical method, observing microstructure, measuring polarization behaviors and hardness. The weld metal zone welded with E4313 electrode exhibited the lowest value of hardness compared to other weld metal zones. In addition, its zone indicated also the best corrosion resistance than those of other weld metal zones. Furthermore, all of the weld metal zones revealed a relatively better corrosion resistance than those of the base metal zones. and also showed higher hardness than the base metal zones.

Design of 4Kb Poly-Fuse OTP IP for 90nm Process (90nm 공정용 4Kb Poly-Fuse OTP IP 설계)

  • Hyelin Kang;Longhua Li;Dohoon Kim;Soonwoo Kwon;Bushra Mahnoor;Panbong Ha;Younghee Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.509-518
    • /
    • 2023
  • In this paper, we designed a 4Kb poly-fuse OTP IP (Intellectual Property) required for analog circuit trimming and calibration. In order to reduce the BL resistance of the poly-fuse OTP cell, which consists of an NMOS select transistor and a poly-fuse link, the BL stacked metal 2 and metal 3. In order to reduce BL routing resistance, the 4Kb cells are divided into two sub-block cell arrays of 64 rows × 32 rows, with the BL drive circuit located between the two 2Kb sub-block cell arrays, which are split into top and bottom. On the other hand, in this paper, we propose a core circuit for an OTP cell that uses one poly-fuse link to one select transistor. In addition, in the early stages of OTP IP development, we proposed a data sensing circuit that considers the case where the resistance of the unprogrammed poly-fuse can be up to 5kΩ. It also reduces the current flowing through an unprogrammed poly-fuse link in read mode to 138㎂ or less. The poly-fuse OTP cell size designed with DB HiTek 90nm CMOS process is 11.43㎛ × 2.88㎛ (=32.9184㎛2), and the 4Kb poly-fuse OTP IP size is 432.442㎛ × 524.6㎛ (=0.227mm2).

Analysis of Kap-Chon's Water Level by the Waterside Planting (수변 식재에 따른 갑천의 수위 분석)

  • Woo, Won-Jae;Chung, Dong-Yang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.1 no.1
    • /
    • pp.3-17
    • /
    • 1998
  • The purposes of this study is to investigate the possibility of planting trees at space land in the riverside. The space land is for the green space. Calculating the plantable space in the representation section and the flood flowing stability of the existing banks based on the hydrological and meteorological data of the Kap-Chon riverbasin located in Tae-jon, the following results are drawn. (1) The flood discharges in each flow section are $698.7m^3/s$ in section 1, $654.6m^3/s$ in section 2, and $1353.3m^3/s$ in section 3 during 100 years recurrence interval. Because the designed-flood discharges in those sections are $1719.9m^3/s$, $2119.7m^3/s$, and $1512.8m^3/s$ respectively, safety for flood flowing is sufficient in existing banks. (2) The possible clearance for planting trees is 1.80m in section 1, 3.90m in section 2, and 0.01m in section 3. Planting clearance is enough in section 1 and 2. However, planting should be planned after estimating a rise-height due to the bridge piers, because many piers under riverine-highway are now on the construction in section 2. The section 3 does not have sufficient clearance for planting trees, but the planting is possible after getting enough flow area with slope by cutting the terrace land on the river artificially heightened. (3) In case of planting a tree 70cm diameter in $1m^2$ in section 1, the water level increases by 0.60m. Planting a tree in a $48m^2$ area increases the water level by 0.90m. Considering that plantable clearance is 1.8m in section 1, it is sufficient to flow safely. But if the trees are planted so compactly from the upper stream, expected heavy resistance is expected due to caught materials on the trees. So, trees have to be planted widely in upper streams but compactedly in lower streams. (4) The river width without changing, Kap-Chon's flow channel can be snaked in accordance with the nature law the wide terrace land in the riverside. Decreased flow area due to planting trees will be compensated by the inclination of terrace land. And, it is theoretically proved that the flood discharge is safe even though the terrace land on the river is parked similar to the nature. Planting trees in the terrace land of the Kap-chon river to the extent that flood flowing is not adversely affected, we can get the enjoyable park to citizens not spending expensive cost. It also contributes to the recovery of ecosystem, which gives the natural beauty of river and shade to citizens and becomes good natural-educational places for children.

  • PDF

The Experimental Study on Reinforced Slope with Geocomb (지오콤 비탈면 보호공법의 활용에 관한 실험적 연구)

  • Ahn, Won Sik;Kim, Chul Moon;Kim, Ug Ki;Kim, Young Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • Generally levee or revetment becomes weak by erosion (scour) due to saturation of ground with infiltration, flowing water. So when levee or revetment is constructed, slope reinforcement must be installed to prevent failure. In this study experimental test was performed for verifying shear resistance, horizontal permeability and rooting ability of Geocomb designed to address the shortcomings of 3-dimension Geocell. Geocomb is one of geosynthetics and the advanced system of geogrid. According to the results of shear test, internal friction angle of reinforced ground with Geocomb was increasing compared with existing material and horizontal permeability of ground with Geocomb was bigger than geocell, porous geocell reinforcing ground. Lastly rooting ability of geocomb is most excellent. These results determined for the inner surface of the cell is net structure.

A study on the Effects of Load Current for Lifetime of Cable Systems (부하 전류가 케이블의 수명에 미치는 영향에 대한 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.205-209
    • /
    • 2015
  • The economic losses resulted from the accident in the power cables at the power station is not only huge but also requires a great amount of time and expenses to restore to the former condition. In order to prevent these, it is necessary to invent and apply a technique to expect and prevent the accidents. In order to measure insulation resistances of power cables in operation, we derived the relations between load current and temperature. By analyzing data obtained from our measuring equipments, we showed the expected time to change deteriorated cables before accident occurs. We present a result of our study on the effects of the load current on lifetime of 6.6 kV cable systems in operation. With the current flowing through the load of the cable a heat is generated reducing the lifetime of the cable. In order to find out the effect of load current on the lifetime of cable systems, we applied the lifetime theory to the development of two equipments to measure insulation resistance and current of cable systems in operation.

Fashion Design Study on Korean Traditional Image Suitable for Ramie Fabric(I) - The Application of Aesthetic Property of Goguryeo Era Clothing - (모시 소재에 적합한 한국적 이미지의 의상디자인 개발에 대한 연구(제1보) - 고구려 시대 복식의 미적 특징을 적용하여 -)

  • Lee, Mi-Yeon;Lee, Kun-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.1
    • /
    • pp.130-144
    • /
    • 2008
  • A recent concern about Goguryeo era reflects the efforts to find out our spiritual roots, which have descended from the ancient times; Goguryeo clothing study leads to analysis of our national spirit in terms of form. This study aims to analyze formal property and intrinsic meaning of Goguryeo clothing for Korean ramie clothing design and draw traditional images to derive design elements applicable to ramie clothing. On the basis of technical books, newspaper article, internet and precedent studies, theoretical study on Goguryeo clothing and ramie property was followed up with positive study to analyze the clothing on the Goguryeo ancient tomb mural. The results are as follows: First, a progressive spirit is to progress and develop anything actively; This spirit represents Goguryeo people's ambition and racial characteristic as horse-riding people; The rigidity of ramie fabric is suitable for expressing straight silhouettes and detail in Goguryeo dress. Second, a fluidity means flowing property in opposition to fixation; in the case of clothing, it has a tendency to change form according to body motions; The extensibility and crease-resistance of ramie fabric is suitable to express pleated skirts and holds high design value for modern people who tend to regard clothing as important individuality expression. Third, a universal property to introduce and receive; as Goguryeo was a prosperous country established by conquering an open plain, the period formed a society that recognized diversity by introducing foreign cultures freely; a universality suggests the direction of modernization of traditional ramie clothing and stimulates us to discovert new design through compromise between various cultures rather than to stick to traditional style. Considering the fact that precedent studies on traditional clothing are concentrated upon the Joseon period and also limited to formal analysis, this study aims to derive design elements for actual clothing making. These results are expected to be used as basic material for study as well as reference for designers who wish to design modern Korean clothing.

  • PDF

The Kinetics of Anodic Dissolution and Repassivation on 316L Stainless Steel in Borate Buffer Solution Studied by Abrading Electrode Technique

  • Xu, H.S.;Sun, D.B.;Yu, H.Y.;Meng, H.M.
    • Corrosion Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.261-266
    • /
    • 2015
  • The capacity of passive metal to repassivate after film damage determines the development of local corrosion and the resistance to corrosion failures. In this work, the repassivation kinetics of 316L stainless steel (316L SS) was investigated in borate buffer solution (pH 9.1) using a novel abrading electrode technique. The repassivation kinetics was analyzed in terms of the current density flowing from freshly bare 316L SS surface as measured by a potentiostatic method. During the early phase of decay (t < 2 s), according to the Avrami kinetics-based film growth model, the transient current was separated into anodic dissolution ($i_{diss}$) and film formation ($i_{film}$) components and analyzed individually. The film reformation rate and thickness were compared according to applied potential. Anodic dissolution initially dominated the repassivation for a short time, and the amount of dissolution increased with increasing applied potential in the passive region. Film growth at higher potentials occurred more rapidly compared to at lower potentials. Increasing the applied potential from 0 $V_{SCE}$ to 0.8 $V_{SCE}$ resulted in a thicker passive film (0.12 to 0.52 nm). If the oxide monolayer covered the entire bare surface (${\theta}=1$), the electric field strength through the thin passive film reached $1.6{\times}10^7V/cm$.

Multi-Current Distributed Folded Monopole Antenna for Triple Band Mobile Phone Handset (3중 대역 휴대폰 단말기용 다중 전류 분포 폴디드 모노폴 안테나)

  • Son, Tae-Ho;Lee, Jae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1189-1195
    • /
    • 2007
  • We design and fabricate, in this parer, a triple band folded monopole antenna for the folder type mobile phone handset that can be served GSM/DCS/USPCS mobile phone system. Antenna structure is modified meander shape which is obtained both extension of antenna physical length for GSM band and same directional multi-currents flowing on the antenna conductor surface for DCS/USPCS band. This antenna has as good performances as high radiation resistance and gain increment, and would be applied to mobile phone handset that is not able to be performed by internal antenna. By measurement, fabricated antenna by the press process shows under VSWR 3:1 at closed folder state and 2:1 at opened folder state over whole GSM/DCS/USPCS band, and has maximum gain as -0.02 dBi for GSM, +0.2 dBi for DCS, +0.78 dBi for USPCS band with almost omnidirectional H-plane radiation pattern.