• Title/Summary/Keyword: flowable 복합레진

Search Result 68, Processing Time 0.041 seconds

A STUDY ON PHYSICAL PROPERTIES OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 물리적 성질에 대한 연구)

  • Kim, Ji-Young;Jeong, Byung-Cho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.423-429
    • /
    • 2002
  • Recently, the clinical uses of flowable composite resins have increased because of fast, convenient and excellent accessibility, but little has been reported about physical properties of flowable resins. The purpose of this study was to measure and compare the physical properties(compressive strength, relative flowability, relative radiopacity) of 4 contemporary flowable composite resins(Filtek flow, Tetric Flow, Revolution Palfique Estelite LV high flow). The results were as follows; 1. There were no significant differences between 4 flowable composite resins in compressive strength, but all were lower than that of traditional hybrid composite resin(p<0.001). 2. The relative flowability were increased in order of Palfique Estelite LV high flow, Revolution, Filtek flow, Tetric Flow and sealant(p<0.001), but there were no significant differences between Filtek flow and Tetric Flow. 3. There were significant differences between flowable composite resins in relative radiopacity and they showed similar or higher radiopacity than dentin(p<0.001), especially Tetric Flow and Filtek Flow showed higher radiopacity than enamel(p<0.001). This results suggested that the stress of application area have to be considered since flowable composite resins have lower compressive strength than hybrid composite, and the differences of flowability between these flowable composite resins can be considered when they are selected. All tested flowable composite resins showed optimal radiopacity to ISO's recommend.

  • PDF

EVALUATION OF THREE FLOWABLE COMPOSITES AS PIT AND FISSURE SEALANTS WITHOUT USING BONDING AGENTS (접착제 미 사용시 치면열구전색제로서의 유동성 복합레진 평가)

  • Kwon, Ho-Beom;Kim, Myoung-Jin;Shin, Cheol-Hwan;Kim, Ji-Yeon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.244-252
    • /
    • 2006
  • The aims of this study were to determine if flowable composites can be used as pit and fissure sealants without bonding agents. Three flowable composites(Filtek Flow, Tetric Flow, Charmfil Flow) and a filled sealant (Ultraseal XT plus) were used. The pattern of resin tag formation in the four sealant materials were compared using SEM. For the microleakage assessment, 54 extracted human premolar teeth were randomly divided into 3 groups containing 18 premolars each. In each group, a conventional filled sealant and one of the three flowable composites were applied to occlusal fissures. The teeth were thermocycled(1200 cycles between $5^{\circ}{\pm}2^{\circ}C\;and\;55^{\circ}{\pm}2^{\circ}C$ with a dwell time of 30 seconds) and immersed in a 1% methylene blue solution for 48 hours. Each tooth was sectioned and examined to determine the extent of dye penetration. Three flowable composites and a filed sealant showed a similar resin tag formation pattern. The three flowable composites showed significantly more microleakage in each group than the filled sealant. The level of microleakage was similar in the three flowable composites. Flowable composites are not recommended as pit and fissure sealants because more microleakage can occur even when occlural fissures are mechanically widened.

  • PDF

Polymerization Shrinkage and Stress of Silorane-based Dental Restorative Composite (Silorane-기질 치아 수복용 복합레진의 중합수축과 중합수축응력)

  • Lee, In-Bog;Park, Sung-Hwan;Kweon, Hyun-Jeong;Gu, Ja-Uk;Choi, Nak-Sam
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.182-188
    • /
    • 2013
  • The purpose of this study was to measure the volumetric polymerization shrinkage kinetics and stress of a silorane-based dental restorative composite and compare it with those of conventional methacrylate-based dental composites. Two methacrylate-based composites (Z250, Z350 flowable) and one silorane-based composite (P90) were investigated. The volumetric polymerization shrinkage of the composites during light curing was measured using a laboratory-made volume shrinkage measurement instrument based on the Archimedes' principle, and the polymerization stress was also determined with the strain gage method. The shrinkage of silorane-based composites (P90) was the lowest, and that of Z350 flowable was the highest. Peak polymerization shrinkage rate was the lowest in P90 and the highest in Z350 flowable. The time to reach peak shrinkage rate of P90 was longer than those of the methacrylate-based composites. The polymerization shrinkage stress of P90 was lower than those of the methacrylate-based composites.

SLUMPING TENDENCY AND RHEOLOGICAL PROPERTY OF FLOWABLE COMPOSITES (Flowable 복합레진의 slumping 경향과 유변학적 성질)

  • Lee, In-Bog;Min, Sun-Hong;Kim, Sun-Young;Cho, Byung-Hoon;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • The aim of this study was to develop a method for measuring the slumping resistance of flowable resin composites and to evaluate the efficacy using rheological methodology. Five commercial flowable composites (Aelitefil flow:AF, Filtek flow:FF, DenFil flow:DF, Tetric flow:TF and Revolution:RV) were used. Same volume of composites in a syringe was extruded on a glass slide using a custom-made loading device. The resin composites were allowed to slump for 10 seconds at $25^{\circ}C$ and light cured. The aspect ratio (height/diameter) of cone or dome shaped specimen was measured for estimating the slumping tendency of composites. The complex viscosity of each composite was measured by a dynamic oscillatory shear test as a function of angular frequency using a rheometer. To compare the slumping tendency of composites, one way-ANOVA and Turkey's post hoc test was performed for the aspect ratio at 95% confidence level. Regression analysis was performed to investigate the relationship between the complex viscosity and the aspect ratio. The results were as follows. 1. Slumping tendency based on the aspect ratio varied among the five materials (AF

Survival Rates of Class II Restoration in Primary Molar with Flowable Resin Composite (유동성 복합레진을 이용한 유구치 II급 수복의 생존율)

  • Seo, Hyejun;Park, Soyoung;Lee, Eungyung;Jeong, Taesung;Shin, Jonghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.12-20
    • /
    • 2021
  • The purpose of this retrospective study was to evaluate the survival rate by comparing Class II restoration using flowable resin composite with stainless steel crown in primary molars. Electronic medical records and radiographs of 1,504 primary molars with proximal caries of 590 patients from June 2015 to August 2019 were analyzed. With the collected data, survival analysis was performed using the Kaplan-Meier method. The 1-year survival rate of flowable resin composite in the primary molar was 98.5%, 3-year survival rate was 87.7%, and mean survival time was 39 months. There was no statistically significant difference between flowable resin composite and stainless steel crown (p = 0.896). Within the limits of this study, Class II restoration using flowable resin composite can be considered a promising option for the treatment of proximal caries in primary molars.

THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN (유동성 레진의 두께가 미세누출에 미치는 영향)

  • Song, Gi-Gang;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.363-371
    • /
    • 2005
  • This study investigated the effect of thickness of flowable resin lining on marginal leakage in class II composite restorations. 80 experimental teeth were prepared with class II preparations with enamel margin or dentin margin. Each group was devided into four groups according to flowable resin lining thickness ; Control group - no flowable resin lining, Group 1 - 0.5 mm flowable resin lining, Group 2 - 1 mm flowable resin lining, Group 3 - 2 mm flowable resin lining. The cavities were restored using Scotchbond Multi-Purpose adhesive system, Filtek Flow and Filtek Z 250 composite resin. Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles and immersed in $2\%$ methylene blue for 24 hours. The results of this study were as follows : 1. Ranking of mean microleakage scores at the enamel margins was Group 1 < Control = Group 2 < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 and Group 2 (p < 0.05). 2. Ranking of mean microleakage scores at the dentin margins was Group 1 < Group 2 < Control < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 (p < 0.05) 3. Compared with microleakage between the enamel and dentin margins, enamel margin group were significantly lower than dentin margin group.

IS AN OXYGEN INHIBITION LAYER ESSENTIAL FOR THE INTERFACIAL BONDING BETWEEN RESIN COMPOSITE LAYERS? (Layering시 복합레진 층간의 계면 결합에서 oxygen inhibition layer가 필수적인가?)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • This study was aimed to investigate whether an oxygen inhibition layer (OIL) is essential for the interfacial bonding between resin composite layers or not. A composite (Z-250, 3M ESPE) was filled in two layers using two aluminum plate molds with a hole of 3.7 mm diameter. The surface of first layer of cured composite was prepared by one of five methods as followings, thereafter second layer of composite was filled and cured: Group 1 - OIL is allowed to remain on the surface of cured composite; Group 2 - OIL was removed by rubbing with acetone-soaked cotton; Group 3 - formation of the OIL was inhibited using a Mylar strip; Group 4 - OIL was covered with glycerin and light-cured; Group 5 (control) - composite was bulk-filled in a layer. The interfacial shear bond strength between two layers was tested and the fracture modes were observed. To investigate the propagation of polymerization reaction from active area having a photo-initiator to inactive area without the initiator, a flowable composite (Aelite Flow) or an adhesive resin (Adhesive of ScotchBond Multipurpose) was placed over an experimental composite (Exp_Com) which does not include a photoinitiator and light-cured. After sectioning the specimen, the cured thickness of the Exp_Com was measured. The bond strength of group 2, 3 and 4 did not show statistically significant difference with group 1. Groups 3 and 4 were not statistically significant different with control group 5. The cured thicknesses of Exp_Com under the flowable resin and adhesive resin were 20.95 (0.90) urn and 42.13 (2.09), respectively.

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.

A STUDY ON THE CLINICAL USAGE OF THE FLOWABLE COMPOSITE RESIN (유동성 복합레진의 임상적 용도에 관한 검토 연구)

  • Park, So-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • The purpose of this study was to compare the microleakage pattern of flowable composite resin to sealant, composite resin used in preventive resin restoration and glass ionomer cement used as liner. 120 extracted sound human molars were divided into 6 groups : group 1 and 2:sealant ; group 3 and 4:preventive resin restoration ; group 5 and 6:sandwich technique restoration. For the experimental groups(group 2, 4 and 6), flowable composite resin(Tetric flow) was used. For the control group, Concise was used as sealant material(group 1), Z-100 with Concise were used as preventive resin restoration(group 3), and Vitrebond was used as cavity liner(group 5). All the restorations were thermocycled and the degree of dye penetration was evaluated with stereomicroscope. The microleakage of each group was measured and statistically analyzed. The results of the present study were as follows : 1. In group 1 and 2, there was no statistically significant difference in microleakage between Concise and Tetric flow(p>0.05). 2. In groups of preventive resin restorations, there was no statistically significant difference in microleakage between Z-100 with Concise and Tetric flow(p>0.05). 3. The microleakage of Vitrebond and Tetric flow used as liner showed no statistically significant difference(p>0.05).

  • PDF

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN (유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구)

  • Park, Heon-Jeong;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.419-430
    • /
    • 2000
  • The purpose of this study was to compare the microleakage pattern of preventive resin restoration using conventional composite resin and flowable composite resin that recently developed. 60 sound premolar teeth were allocated to three groups. Flowable composite resin was used for the experimental groups(Group I and II) and conventional resin for the control group(Group III). After composite filling and sealant application, all teeth were thermocycled and evaluated for microleakage under light microscope. Additionally, a variety of voids formed inside restorations were also evaluated. Data were analyzed statistically using Kruskal-Wallis test and/or Mann-Whitney U-test. The results of the present study were as follows. 1. Microleakage found in all samples was only limited to the interface of restoration margin and enamel. 2. The flowable composite resin groups (Group I, II) generally showed less microleakage than control groups (conventional preventive resin restoration) (p<0.05) 3. Various types of voids were observed in most specimens. Especially, there was a tendency for more and larger voids to be found in group I, II than group III (p<0.05).

  • PDF