• Title/Summary/Keyword: flow simulator

Search Result 379, Processing Time 0.025 seconds

Effect of Dynamic Flow on the Structure of Inhibition Layer in Hot-dip Galvanizing

  • Jin, Young Sool;Kim, Myung Soo;Kim, Su Young;Paik, Doo Jin
    • Corrosion Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • The effect of dynamic flow or forced convection were investigated and compared on the formation of inhibition layer, galvanizing and galvannealing reactions through the hot-dip galvanizing simulator with the oscillation of specimen in zinc bath, continuous galvanizing pilot plant with zinc pumping system through the snout and continuous galvanizing operation with Dynamic $Galvanizing^{TR}$ system. The interfacial Al pick-up was not consistent between the results of simulator, pilot plant and line operation, but the morphology of inhibition layer became compact and refined by the forced convection. The growth of Fe-Zn intermetallics at the interface was inhibited by the forced convection, whereas the galvannealing rate would be a little promoted.

Analysis on Characteristics of Thermal Flow of Hot Air in Single Shell of Shell and Tube-type Heat Exchanger (쉘앤튜브형 열교환기의 단일 쉘 내 고온공기 열유동 특성 해석)

  • Young-Joon Yang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.255-263
    • /
    • 2023
  • The shell and tube-type heat exchangers have been frequently used in many industrial field because of its simple structure and wide operation conditions and so on. The purpose of this study is to investigate the flow characteristics in single shell of shell and tube-type heat exchanger according to velocity and temperature of hot air released from heat exchanger simulator through numerical analysis. As the results, the temperature was decreased in almost quadratic curve from top to bottom in single shell of the shell and tube-type heat exchanger. Further the changes of pressure and velocity in outlet according to change of inlet temperature were not observed. The cost for operating the shell and tube-type heat exchanger should be compared the supply cost of hot air with that of velocity in order to make a economic decision.

Laboratory investigation of the effects of translation on the near-ground tornado flow field

  • Razavi, Alireza;Sarkar, Partha P.
    • Wind and Structures
    • /
    • v.26 no.3
    • /
    • pp.179-190
    • /
    • 2018
  • Translation of tornadoes is an important feature in replicating the near-ground tornado flow field which has been simulated in previous studies based on Ward-type tornado simulators using relative motion of the ground plane. In this laboratory investigation, effects of translation on the near-ground tornado flow field were studied using the ISU Tornado Simulator that can physically translate over a ground plane. Two translation speeds, 0.15 m/s and 0.50 m/s, that scale up to those corresponding to slowly-moving tornadoes in the field were selected for this study. Compared with the flow field of a stationary tornado, the simulated tornado with translation had an influence on the spatial distribution and magnitude of the horizontal velocities, early reversal of the radial inflow, and expansion of the core radius. Maximum horizontal velocities were observed to occur behind the center of the translating tornado and on the right side of its mean path. An increase in translation speed, resulted in reduction of maximum horizontal velocities at all heights. Comparison of the results with previous studies that used relative motion of the ground plane for simulating translating tornadoes, showed that translation has similar effects on the flow field at smaller radial distances (~2 core radius), but different effects at larger radial distances (~4 core radius). Further, it showed that the effect of translation on velocity profiles is noticeable at and above an elevation of ~0.6 core radius, unlike those in studies based on the relative motion of the ground plane.

Development of a Simulator for Automated Manufacturing Systems (객체지향방식에 의한 자동화제조시스템 시뮬레이터의 설계 및 구현)

  • 이진규;이진환;이태억;오부경;오석찬
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1997.04a
    • /
    • pp.23-28
    • /
    • 1997
  • We discuss development of a simulator for automated manufacturing systems (AMSs) which have sophisticated automated material handling equipments and complicated work flows. The simulator is designed to satisfy the following requirements. A user should be able to easily configure or specify an AMS through a graphical user interface (GUI) and minimal data input. The user should be able to model diverse and complied control logic for automated material handling systems like automated guided vehicle (AGV) systems, robot workcell systems and conveyor systems as well as complicated job flow program. Real time animation is desired. Finally, the simulator should be easily maintained and extended. To satisfy the requirements, we use an object-oriented paradigm for modeling, designing, and programming of the simulator. We use an object-oriented modeling framework to design the modeling elements library, and take the process interaction approach for scheduling processes and events. To model a user-defined diverse control logic, we also develop a script language and its interpreter. We explain design and implementation strategies. We implement the simulator using Visual C++ 4.2 and Open GL on Windows NT and the Windows95. Some modeling examples will be demonstrated.

  • PDF

Evaluation of methods for estimating the pulse reflection site with cardiovascular simulator (심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 2015
  • Objective Wave reflection is an important factor that determines the shape of the pulse wave. The purpose of this study is to compare the conventional method used for estimating the reflection site of pulse with a cardiovascular simulator. Methods: In this study, cardiovascular simulator with one elastic tube was used. The pressure and flow was measured simultaneously at three different points. The measured data were used to the conventional methods to estimate the pulse wave reflection site. The results were compared with the known length which were the distances from the measured points to the end of tube. Results & Conclusions: There is a significant error with the time domain method. While, the reflection site with the frequency domain method was similar to the actual reflection site.

Development of Web-based Simulator for Supply Chain Network with Reconfigurable Manufacturing System and Multi-layered Distribution Center (재구성가능 제조시스템과 다계층 구조를 가지는 분배센터로 구성된 공급사슬망을 위한 웹기반 시뮬레이터 개발)

  • Seo, Min-Seok;Lim, Dae-Eun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.37 no.4
    • /
    • pp.279-288
    • /
    • 2011
  • The past researches focused on the supply chain network that consists of factories, distribution centers and retailers for single product type. This research is required because the factory for single product type is advanced to reconfigurable type in order to produce various products, according to customers' various purchase forms and time. This research is also required because in the past researches, the material flows from factories to distribution centers and from distribution centers to retailers, but recently, there are material flows between distribution centers. The supply chain network in this research consists of reconfigurable manufacturing system, multi-layered distribution centers, and retailers. A simulator is developed to analyze the material flow on the supply chain network. The developed simulator is web-based designed by using Java Server Page and MS-SQL, so as to maximize the convenience for users.

Introduction to Graphic-based Power System Simulator (Graphic-based Power System Simulator 소개)

  • Shin, M.C.;Kim, K.J.;Eum, J.S.;Rhee, B.;Park, C.W.;Jang, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.133-136
    • /
    • 2001
  • In this paper the Graphic-based Power System Simulator(GPSS) program is introduced. GPSS is a Power System Simulator that is designed to provide friendly and highly interactive Graphic User Interface(GUI). The main features of GPSS are graphical free editing, quick and fine System-Drawing and Load-Flow analysis. Most of all, mapping power system data(only pure text information) into Graphic Data is of very practical use to power system designer and analyst.

  • PDF

The implementation of a virtual Plant simulator for the PLC Programming (PLC 프로그래밍을 위한 가상 플랜트 시뮬레이터 구현)

  • Lee, Gi-Bum;Kim, Se-Yeon;Lee, Jin-S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.475-477
    • /
    • 1998
  • In this paper, the implementation of a virtual Plant simulator for the PLC programming is presented. A virtual plant simulator that replaces function of transducers (e.g. pumps and valves) consists of a personal computer and a PLC(Programmable logic controller). Input/output conponents are edited on the monitor and are operated as the field transducers. The timing process for input/output components is analyzed. The data flow between a PLC system and a virtual plant simulator is carried out.

  • PDF

Timing Simulator by Waveform Relaxation Considering the Feedback Effect (피이드백 효과를 고려한 파형이완 방식에 의한 Timing Simulator)

  • Jun, Young Hyun;Lee, Chang Woo;Lee, Kijun;Park, Song Bai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.347-354
    • /
    • 1987
  • Timing simulators are widely used nowadays for analyzing large-scale MOS digital circuits, which, however, have several limitations such as nonconvergence and/or in accuracy for circuits containing tightly coupled feedback elements or loops. This paper describes a new timing simulator which aims at solving these problems. The algorithm employed is based on the wave-form relaxation method, but exploits the signal flow along the feedback loops. Each of feedback loops is treated as one circuit block and then local iterations are performed to enhance the timing simulation. With these techniques, out simulator can analyze the MOS digital circuits with up to 5-20 times of the magnitude speed improvemnets as compared to SPICE2, while maintaining the accuracy.

  • PDF

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).