• 제목/요약/키워드: flow phantom

검색결과 60건 처리시간 0.026초

복합 [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$ 시이퀸스를 이용한 핵자기 공명 혈관 조영술 (MR ANGIOGRAPHY USING THE COMPOSITE [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] SEQUENCE)

  • 김재호;이기동;전현호;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.35-37
    • /
    • 1989
  • A new MR angiography technique using a composite sequence for the suppression of static sample signals is proposed and verified with experiments. When the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is applied, the large signal from the static sample is sufficiently suppressed but the signal from fresh inflow sample of which amplitude. is observed without suppression. These properties are appropriate for angiographic applications. In this paper, a modified line scan method (Block line scan angiography) incorporated with the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is used to obtain flow-only images, i.e., angiograms. The block line scan method improves the resolution in the flow-direction at the expense of imaging time. With the composite sequence, there is no need for subtraction procedure as in the most conventional angiographic methods. Experimental results for a phantom and a normal volunteer with KAIS 2.0 Tesla MRI system are shown.

  • PDF

대학생의 자기주도성, 학습몰입, 진로결정효능감과 진로탐색행동 간의 관계 구조분석 (The Analysis on the Causal Model between Self-directedness, Learning Flow, Career Decision and Self-efficacy, and Career Exploration Behavior of Undergraduate Students)

  • 강명숙;방은령
    • 한국심리학회지 : 문화 및 사회문제
    • /
    • 제20권4호
    • /
    • pp.443-467
    • /
    • 2014
  • 본 연구는 대학생을 대상으로 자기주도성, 학습몰입, 진로결정효능감과 진로탐색행동 간의 관계 구조를 검증하고자 하였다. 이를 위하여 남녀 대학생 604명을 대상으로 자기보고식 설문조사를 하였고, 구조방정식을 활용하여 자료를 분석하였다. 본 연구의 주요결과는 다음과 같다. 첫째, 학습몰입과 진로결정효능감은 진로탐색행동에 긍정적인 영향을 미치는 선행변인으로 밝혀졌으나, 자기주도성이 진로탐색행동에 미치는 직접적인 영향은 유의하지 않은 것으로 나타났다. 둘째, 자기주도성은 학습몰입과 진로결정효능감에 긍정적인 영향을 미치는 것으로 나타났다. 셋째, 진로결정효능감과 학습몰입은 자기주도성과 진로탐색행동의 관계를 완전 매개함으로써 자기주도성이 진로탐색행동에 간접적인 영향을 미치는 것으로 나타났다. 특정간접효과(specific indirect effect)의 크기를 검토하였을 때, 자기주도성의 간접효과는 진로결정효능감을 매개하는 경로가 학습몰입을 매개하는 경로보다 진로탐색행동에 미치는 영향력이 더 큰 것으로 밝혀졌다. 이러한 결과를 토대로 대학생의 진로탐색행동을 증진시키기 위한 논의와 후속연구를 위한 제언이 이루어졌다.

  • PDF

List Mode에서 PET/CT Scanner의 직선성 평가 (Linearity Estimation of PET/CT Scanner in List Mode Acquisition)

  • 최현준;김병진;이또 미키코;이홍재;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.86-90
    • /
    • 2012
  • Rb-82를 이용한 PET 검사는 심근 관류의 임상적 평가에 중요한 역할을 한다고 알려져 있다. 그러나 PET/CT의 dead time 때문에 count value와 방사능농도 사이의 직선성이 유지되지 않는다면 데이터를 획득할 때 좌심실 입력 함수가 과대평가되어 심근관류가 과대평가될 수 있다. 본 연구에서는 리스트 모드에서 획득한 PET data에서 방사능농도에 따른 count value의 직선성을 평가하였다. Biograph 40 True Point PET/CT를 이용하여 직경 12 cm, 길이 10.5 cm의 cylindrical phantom에 F-18 333 MBq과 물 800 mL를 채우고 7반감기동안 10min frame/bed로 리스트 모드를 이용하여 획득하였다. Raw data는 OSEM (order: 4, subsets: 8)과 FBP (Gaussian filter FWHM 5 mm) 알고리즘을 이용하여 재구성하였다. Sinogram 정보에서 prompt counts, net true counts, random counts를 측정하였다. 재구성 된 phantom 영상에 ROI를 설정하여 총 계수와 background를 측정하고 background correction을 사용하여 count value를 측정하여 직선성을 평가하였다. 리스트 모드를 이용하여 sinogram에서 측정된 prompt counts는 방사능농도에 비례하여 증가하였다. 낮은 방사능농도에서 net true counts와 random counts는 방사능농도에 따라 증가하였다. 높은 방사능농도에서는 net true counts의 증가율이 점차 감소되었고, 반면에 random counts의 증가율은 증가하였다. 그리고 OSEM과 FBP 알고리즘으로 재구성된 영상에서 측정한 count value의 차이는 없었고 방사능농도에 비례하여 count value가 증가하고 직선성이 유지되었다. Biograph 40 True Point PET/CT scanner는 재구성된 영상에서 낮은 방사능농도뿐만 아니라 높은 방사능농도(~416.25 kBq/mL)에서도 측정 된 count value와 방사능농도 사이의 직선성이 유지되는 것을 보여주었다. 따라서 실험에서 사용한 PET/CT scanner는 Rb-82, N-13, O-15, F-18을 이용한 heart dynamic PET study에서데이터의 정량적 분석에 유용할 것으로 판단된다.

  • PDF

광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰 (Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry)

  • 김정미;전수동;백금문;조영필;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.123-129
    • /
    • 2010
  • 목 적: 방사선 치료의 선량평가를 위해 사용되는 Optically stimulated luminescent dosimeters (OSLD) 선량 특성을 분석하여, 선량 측정의 유용성을 알아보고자 한다. 대상 및 방법: $NanoDot^{TM}$$Inlight^{TM}$MicroStar Reader, Solid Water Phantom, 의료용 선형가속기 $TRYLOGY^{(R)}$를 사용하였다. 측정 조건은 OSLD를 Solid Water Phantom의 $D_{max}$ 깊이에 위치시킨 후 SSD는 100 cm, Field size는 $10{\times}10\;cm^2$로 하고 300 MU/min으로 6 MV 광자선, 100 cGy의 방사선을 조사하였다. OSLD를 10분 마다 판독하면서 변화값을 측정하였고, OSLD에 선량을 50 cGy와 100 cGy씩 누적시켜 판독하였다. 또한 에너지 의존성은 6 MV, 15 MV, 4~20 MeV를 사용하였다. 선량률은 100~1,000 MU/min로 변화시키면서 측정하였다. 광자선 6 MV의 PDD의 변화를 측정하기 위해 OSLD와 전리함(Ionization chamber) (FC 65P-747)을 사용하였다. 결 과: 시간의 경과에 따른 OSLD의 재현성은 ${\pm}2.5%$였다. OSLD의 선량에 대한 선형성(linearity)을 평가한 결과 300 cGy까지는 선형적으로 증가하였고, 300 cGy 이상에서는 초선형적(supralinearity)으로 증가하였다. 에너지 의존성은 ${\pm}2%$ 이내였고 선량율 의존성은 ${\pm}3%$ 이내였다. 6 MV 광자선에 대하여 OSLD로 측정한 $PDD_{10}$은 66.7%, $PDD_{20}$은 38.4%였고 전리함(Ionization chamber)으로 측정한 $PDD_{10}$은 66.6%, $PDD_{20}$은 38.3%였다. 결 론: OSLD의 특성을 분석한 결과 시간, 에너지, 선량률의 변화에 따른 차이는 ${\pm}3%$ 이내였으며 전리함(Ionization chamber)과 비교한 PDD는 0.3% 이내였다. 또한 300 cGy까지는 선량이 선형적으로 증가하였다. OSLD는 여러 번 반복 측정이 가능하였고 측정과 판독이 용이하여 선량계로서 유용성을 확인하였다.

  • PDF

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

기준표적상의 미세구조가 초음파 후방산란에 미치는 영향 (Influence of Microstructure on Reference Target on Ultrasonic Backscattering)

  • 김호철;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.38-44
    • /
    • 2010
  • This paper is based on our comments and proposed amendments to the documents, Annex A, Phantom for determining Maximum Depth of Penetration, and Annex B, Local Dynamic Range Using Acoustical Test Objects 87/400/CDV. IEC 61391-2 Ed. 1.0 200X, prepared by IEC technical Committee 87; Ultrasonics. The documents are concerned with the influence of microstructure of reference target material on the ultrasonic backscattering. Previous works on the attenuation due to backreflection and backscattering of reference target materials are reviewed. The drawback to the use of ungraded stainless steel and metallic materials without microstructural data such as, crystal structure, basic acoustic data of sound velocity and attenuation, grain size, roughness and elastic constants has been discussed. The analysis suggested that the insightful conclusion can be made by differentiating the influence arising from target size and microstructure on the backscattering measurements. The microstructural parameters are associated with physical, geometrical, acoustical and mechanical origins of variation with frequency. Further clarification of such a diverse source mechanisms for ultrasonic backscattering would make the target material and its application for medical diagnosis and therapy simpler and more reliable.

최적화된 샘플링 인수를 갖는 단일 채널 RF 샘플링 방식의 다중점 펄스 도플러 시스템을 사용한 혈류 속도분포 측정 (Volumetric Blood Velocity Measurement on Multigate Pulsed Doppler System based on the Single Channel RF Sampling using the Optimized Sampling Factor)

  • 임춘성;민경선
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.143-152
    • /
    • 1998
  • In this paper, we present the performances of a Doppler system using single channel RF(Radio Frequency) sampling. This technique consists of undersampling the ultrasonic blood backscattered RF signal on a single channel. Conventional undersampling method in Doppler imaging system have to use a minimum of two identical parallel demodulation channels to reconstruct the multigate analytic Doppler signal. However, this system suffers from hardware complexity and problem of unbalance(gain and phase) between the channels. In order to reduce these problems, we have realized a multigate pulsed Doppler system using undersampling on a single channel, It requires sampling frequency at $4f_o$(where $f_o$ is the center frequency of the transducer) and 12bits A/D converter. The proposed " single-Channel RF Sampling" method aims to decrease the required sampling frequency proportionally to $4f_o$/(2k+1). To show the influence of the factor k on the measurements, we have compared the velocity profiles obtained in vitro and in vivo for different intersequence delays time (k=0 to 10). We have used a 4MHz center frequency transducer and a Phantom Doppler system with a laminar stationary flow. The axial and volumetric velocity profiles in the vessel have been computed according to factor k and have been compared. The influence of the angle between the ultrasonic beam and the flow axis direction, and the fluid viscosity on the velocity profiles obtained for different values of k factor is presented. For experiment in vivo on the carotid, we have used a data acquisition system with a sampling frequency of 20MHz and a dynamic range of 12bits. We have compared the axial velocity profiles in systole and diastole phase obtained for single channel RF sampling factor.ng factor.

  • PDF

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

${H_2}^{15}O$ PET을 이용한 뇌혈류 파라메트릭 영상 구성을 위한 알고리즘 비교 (Comparison of Algorithms for Generating Parametric Image of Cerebral Blood Flow Using ${H_2}^{15}O$ PET Positron Emission Tomography)

  • 이재성;이동수;박광석;정준기;이명철
    • 대한핵의학회지
    • /
    • 제37권5호
    • /
    • pp.288-300
    • /
    • 2003
  • 목적: ${H_2}^{15}O$ PET의 정량화를 위하여 1-조직 구획모델이 쓰이며, 뇌혈류와 조직/혈액 분배계수를 구하기 위하여 nonlinear least squares (NLS) 방법이 사용되나 계산 시간이 긴 등의 문제로 파라미터를 각화소마다 구해야 하는 파라메트릭 영상 구성에는 적합하지 않다. 이 연구에서는 이와 같은 NLS 문제점을 극복하여 파라메트릭 영상을 빠르게 구성하기 위하여 제안된 파라미터 추정 알고리즘들을 구현하고, 이 방법들의 통계적 신뢰도와 계산의 효율성을 비교하였다. 대상 및 방법: 이 연구에서 이용한 방법들은 linear least squares (LLS), linear weighted least squares (LWLS), linear generalized least squares (GLS), linear generalized weighted least squares (GWLS), weighted integration (WI), 그리고 model-based clustering method (CAKS)이다. 노이즈 정도에 따른 각 파라메트릭 영상법의 정확성 및 통계적 신뢰성을 알아보기 위하여 Zubal 뇌모형(brain phantom)으로부터 동적 PET 영상을 모사하고 포아송노이즈를 더한 후 각 파라메트릭 영상 구성 방법을 적용하였다. 또한 정상인 16명에 대하여 얻은 실제 자료에 대하여 이 방법들을 적용하고 결과를 비교하였다. 결과: 뇌혈류와 분배계수에 대한 평균 오차는 방법에 따라 크게 다르지 않았으며 모든 방법이 뇌혈류 및 분배계수 추정에 있어 무시할 만한 바이어스를 보였다. 파라메트릭 영상의 정성적 특성 또한 유사하였으나 CAKS 방법의 계산 속도가 월등하여 NLS 방법의 약 1/500, LLS 방법의 약 1/25의 계산시간을 보였다. 결론: 뇌혈류 파라메트릭 영상 구성을 위한 빠른 파라미터 추정 알고리즘들 중에 보다 개선되어 제안된 LWS, GLS, GLWS, CAKS 방법들이 단순하고 빠른 LLS, WI 방법들에 비하여 통계적 신뢰성을 크게 향상시키지는 못하나 CAKS 방법은 계산 시간을 유의하게 단축시키므로 가장 적합한 파라메트릭 영상 구성방법이라 할 수 있을 것이다.