Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.18
no.4
/
pp.22-27
/
2004
The gas discharge AND gate which have been newly proposed is applied to three electrode surface discharge AC PDP. The address discharge characteristics by the DC-AC floating discharge by which Y electrode is made floating electrode is analyzed The address discharge can be begun by using the floating discharge from the experiment result Moreover, the display discharge can be sustained. The DC priming discharge that the floating discharge is matched to timing is generated in a supplementary electrode. As a result, space charge is supplied enough to the space of the floating discharge and the data voltage is lowered up to l00(V). Driving method to use this DC-AC floating discharge is able to obtain the address operation margin of l00(V).
Journal of the Korea Institute of Military Science and Technology
/
v.15
no.2
/
pp.121-129
/
2012
In this study, in terms of the exercise vehicles of the weapon systems having negative buoyancy, the analysis on the operation concepts was performed and the new methods of floating to surface were proposed. In case of having negative buoyancy, the additional methods for recovering the exercise vehicle have to be considered. As parts of recovering the exercise vehicle, for floating to surface the new methods of weight discharge, weight separation and sea water discharge were proposed. The conceptual design about sea water discharge method was performed. It was confirmed that those methods could be applied to the design of the exercise vehicle having negative buoyancy.
Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
/
2003.11a
/
pp.49-53
/
2003
본, 연구는 새로운 기체방전 AND gate를 AC 3전극 면방전 PDP에 적용하기 위한 AC-DC floating 방전을 사용한 어드레스 구동특성을 해석한 것이다. 실험결과 floating 방전을 이용하여 어드레스 방전을 개시시킬 수 있었으며 표시방전까지 용이하게 동작시킬 수가 있었다. 또한 floating 방전과 타이밍을 동기시켜 보조전극에 프라이밍 방전을 일으켜 줌으로써 floating 방전 공간에 공간전하를 충분히 공급해 줌으로써 데이터 전압을 100V 정도까지 낮출 수 있었으며 어드레스 동작 마진도 100V 정도까지 얻을 수가 있었다.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.18
no.3
/
pp.34-39
/
2004
This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.18
no.4
/
pp.112-117
/
2004
This paper describes the analysis of the UHF signal characteristics due to the partial discharge sources which can exist in a GIS. For the experiment, a model GIS was made and 5 types of discharge source were created as follows; corona discharge, surface discharge, void discharge, discharge due to free particle, discharge from floating electrode. The frequency spectra and the phase characteristics of UHF signals were induced by UHF signal analysis. The results were quantified to systematically adapt to analyze the PD sources in the GIS and utilized as algorithm data based on the neural network for Back-Propagation Algorithm with a multi-layer structure. The perception rate of the constructed algorithm showed approximately 94[%] and 82[%] in learning and testing data, respectively.
The Journal of the Korea institute of electronic communication sciences
/
v.10
no.2
/
pp.157-164
/
2015
The present study is to identify discharge characteristic from the mouth of floating debris in the Nakdong River through real time tracking of moving route and by analyzing hydrometeorologic environmental. To identify the path and route of outflow through the mouth of the river of floating debris, small-sized buoy equipped with satellite location transmitters was used. Moreover, to identify hydrometeorologic environmental, flux of the river, change of discharge of the River-Mouth Weir and wind direction of the mouth of the river area were analyzed. From now on, the present study is expected to be utilized as basic data to identify damage and flowing into nearby ocean of the floating debris of Nakdong River in time of severe rain storm.
Han, Il Yeong;Choi, Heung Sik;Lee, Ji Haeng;Ra, Sung Min
Journal of Korea Water Resources Association
/
v.51
no.5
/
pp.405-415
/
2018
Hydraulic variables such as discharge coefficient, gate opening, and upstream water depth are required to calculate the discharge of vertical lift gate. It is very important for a precise gate design, because it may affect the rest, to predict the behavior of gate opening during operation. In this study, an equation by which gate opening could be predicted with any upstream water depths was derived from the relation between the calculated value from buoyancy theory and measured one from experiment for a floating gate model. Downpull force was the reason for the differences between the calculated and the measured and it was verified using pressure coefficient. Also, the relation of discharge coefficient with gate opening ratios was derived. The derived relations were used for flood routing and it was realized that downpull force effect should be fully taken into account during gate design.
In this paper, a structure of GCNMOS based ESD protection circuit using floating-body technique is proposed. TCAD simulation of Synopsys was used to compare with the conventional GGNMOS and GCNMOS. Compared with the conventional GCNMOS, the proposed ESD protection circuit has lower trigger voltage and faster turn-on-time than conventional circuit because of the added NMOSFET. In the simulation result, the triggering voltage of the proposed ESD protection circuit is 4.86V and the turn-on-time is 1.47ns.
The Transactions of the Korean Institute of Electrical Engineers C
/
v.52
no.6
/
pp.267-273
/
2003
The plasma display panel with the electrode structure of new discharge AND gate and its driving scheme were proposed and the driving system for experiment was developed. And operation of these discharge AND gate was verified by the experiment of PDP addressing with floating electrode. This discharge AND gate operated by the operation speed of 8$mutextrm{s}$ and the operation margin of 100V. The address operation margin of 10V also obtained. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because proposed method uses the DC discharge the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of discharge gate are separate, the display discharge can be prevented from passing discharge gates. Therefore, it is possible to apply to the large screen plasma display panel. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.
An atmospheric pressure floating electrode-dielectric barrier discharge (FE-DBD) system having flexible electrodes was developed and its plasma characteristics was investigated. Polytetrafluoroethylene (PTFE), polydiemethylsiloxane (PDMS), and polyethylene terephthalate (PET) were used as flexible dielectrics for flexible powered-electrodes. The optical intensity and electron temperature of the atmospheric pressure FE-DBD plasma increased with the voltage applied to the powered electrode, and increased in the order of PTFE < PDMS < PET at a fixed voltage. This behavior was explained in terms of the change in the capacitance of the flexible dielectrics with the dielectric type and voltage, implying that the plasma characteristics of an atmospheric pressure FE-DBD having flexible electrodes can be controlled by modulating the flexible dielectrics for the flexible powered-electrode and the voltage applied to the powered electrode. Because an atmospheric pressure FE-DBD system can generate a plasma along the curvature of skins, it is expected to have useful applications in plasma medicine.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.