• Title/Summary/Keyword: flat output

Search Result 168, Processing Time 0.028 seconds

Analysis of Lower-Limb Motion during Walking on Various Types of Terrain in Daily Life

  • Kim, Myeongkyu;Lee, Donghun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.319-341
    • /
    • 2016
  • Objective:This research analyzed the lower-limb motion in kinetic and kinematic way while walking on various terrains to develop Foot-Ground Contact Detection (FGCD) algorithm using the Inertial Measurement Unit (IMU). Background: To estimate the location of human in GPS-denied environments, it is well known that the lower-limb kinematics based on IMU sensors, and pressure insoles are very useful. IMU is mainly used to solve the lower-limb kinematics, and pressure insole are mainly used to detect the foot-ground contacts in stance phase. However, the use of multiple sensors are not desirable in most cases. Therefore, only IMU based FGCD can be an efficient method. Method: Orientation and acceleration of lower-limb of 10 participants were measured using IMU while walking on flat ground, ascending and descending slope and stairs. And the inertial information showing significant changes at the Heel strike (HS), Full contact (FC), Heel off (HO) and Toe off (TO) was analyzed. Results: The results confirm that pitch angle, rate of pitch angle of foot and shank, and acceleration in x, z directions of the foot are useful in detecting the four different contacts in five different walking terrain. Conclusion: IMU based FGCD Algorithm considering all walking terrain possible in daily life was successfully developed based on all IMU output signals showing significant changes at the four steps of stance phase. Application: The information of the contact between foot and ground can be used for solving lower-limb kinematics to estimating an individual's location and walking speed.

Characteristics and Fabrication of Multi-Layered Piezoelectric Ceramic Actuators for Speaker Application (스피커 응용을 위한 적층형 압전 세라믹 액츄에이터 제조 및 특성)

  • Lee, Min-seon;Yun, Ji-sun;Park, Woon Ik;Hong, Youn-Woo;Paik, Jong Hoo;Cho, Jeong Ho;Park, Yong-Ho;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.601-607
    • /
    • 2016
  • Piezoelectric thick films of soft $Pb(Zr,Ti)O_3$ (PZT) based commercial material (S55) were fabricated using a conventional tape casting method. Ag-Pd electrodes were printed on the piezoelectric film at room temperature and all 5 layered films with a dimension of $12mm{\times}16mm$ were successfully laminated for a multi-layered piezoelectric ceramic actuator. The laminated specimens were co-fired at $1,100^{\circ}C$ for 1 h. A flat layered and dense microstructure was obtained for the $112{\mu}m$ thick piezoelectric actuator after sintering process. Thereafter, a prototype piezoelectric speaker was fabricated using the multi-layered piezoelectric ceramic actuator which can operate as a bimorph. Its SPL (sound pressure level) characteristic was also evaluated for speaker application. Frequency response revealed that the output SPL with a root mean square voltage of 10 V increased gradually to the highest peak of 87.5 dB for 1.5 kHz and exhibited a relatively stable behavior over the measured frequency range (${\leq}20kHz$) at a distance of 10 cm, implying that the fabricated piezoelectric speaker is potential for speaker applications.

Comparison of the Detection Efficiency $a-Se_{1-x}As_x$ in X-ray Detection Sensor of $Gd_2O_2S(Eu^{2+})/a$-Se Structure ($Gd_2O_2S(Eu^{2+} )/a$-Se$ 구조의 X선 검출 센서에서 $a-Se_{1-x}As_x$의 검출효율 비교)

  • Kang, Sang-Sik;Park, Ji-Koon;Lee, Dong-Gil;Mun, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.436-439
    • /
    • 2002
  • Recently, It has performed that the basic research of the photoconductive material and the development and application of the digital radiograph detector which is divided into the direct and indirect method. The objective of this study investigate the effect of the electric characteristic about changing the composition of Arsenic in hybrid detector system for compensating a defect of conventional. We fabricated samples using the amorphous Selenium and Arsenic alloy with various concentrations of the Arsenic{seven step 0.1%, 0.3%, 0.5%, 1%, 1.5%, 3%, 5%). And using EFIRON optical adhesives the formed multi-layer$(Gd_{2}O_{2}S(Eu^{2+}))$ composed phosphor layer. X-ray and light sensitivity was measured to study x-ray response characteritics. As results, highest value was measured as output net charge and SNR were $315.7pC/cm^2/mR$ and 99.4 at 0.3%As doping ratio.

  • PDF

Enhancement of Light Extraction Efficiency of GaN Light Emitting Diodes Using Nanoscale Surface Corrugation (나노크기 표면 요철을 이용한 GaN LED의 광추출효율 향상)

  • Jung, Jae-Woo;Kim, Sarah;Jeong, Jun Ho;Jeong, Jong-Ryul
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.636-641
    • /
    • 2012
  • In this study, we have investigated highly efficient nanoscale surface corrugated light emitting diodes (LEDs) for the enhancement of light extraction efficiency (LEE) of nitride semiconductor LEDs. Nanoscale indium tin oxide (ITO) surface corrugations are fabricated by using the conformal nanoimprint technique; it was possible to observe an enhancement of LEE for the ITO surface corrugated LEDs. By incorporating this novel method, we determined that the total output power of the surface corrugated LEDs were enhanced by 45.6% for patterned sapphire substrate LEDs and by 41.9% for flat c-plane substrate LEDs. The enhancement of LEE through nanoscale surface corrugations was studied using 3-dimensional Finite Different Time Domain (FDTD) calculation. From the FDTD calculations, we were able to separate the light extraction from the top and bottom sides of device. This process revealed that light extraction from the top and bottom sides of a device strongly depends on the substrate and the surface corrugation. We found that enhanced LEE could be understood through the mechanism of enhanced light transmission due to refractive index matching and the increase of light scattering from the corrugated surface. LEE calculations for the encapsulated LEDs devices also revealed that low LEE enhancement is expected after encapsulation due to the reduction of the refractive index contrast.

Pulse 2 kW RF Limiter at S-band (S-대역 펄스 2 kW RF 리미터)

  • Jeong, Myung-Deuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.791-796
    • /
    • 2012
  • A RF limiter is a component to protect the receiver front end from undesired signal. A RF limiter is a key component whose output is constant level for all inputs above a critical value. A RF limiter use a diode to pass signals of low power while attenuating those above some threshold. A RF limiter for receiver protection in modern radar systems is playing a vital role in order to meet challenges of new interference threats and complicated electromagnetic environments. This paper proposed a new circuit for high power RF limiter whose structure is the combination of the PIN diode and Limit diode. PIN diode take a use of its isolation characteristics which act as a switch does. A 2 kW RF limiter with 200 us pulse width at S-band was developed. It shows good agreements between estimated value and measured results.

Silicon Capacitive Pressure Sensor for Low Pressure Measurements (저 압력 측정을 위한 실리콘 용량형 압력센서)

  • Seo, Hee-Don;Lee, Youn-Hee;Park, Jong-Dae;Choi, Se-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.19-27
    • /
    • 1993
  • Capacitive pressure sensor for low pressure measurements has been fabricated by using $n^{+}$ epitaxial layer electrochemical etching stop and glass-to-silicon electrostatic bonding technique. The sensor had hybrid configuration of a sensor chip, which consists of sensor capacitor and reference capacitor, and two output signal detection IC chips. A fabricated sensor, with a $1.0{\times}1.0 mm^{2}$ square size and a $10{\mu}m$ thick flat diaphragm, showed a 7.1 pF zero pressure capacitance, and 5.2 % F.S, sensitivity in 10 KPa pressure range. By using a capacitance to voltage converter, the thermal zero shift of 0.051 %F.S./$^{\circ}C$ and the thermal sensitivity shift of 0.12 %F.S./$^{\circ}C$ for temperature range of $5{\sim}45^{\circ}C$ were obtained.

  • PDF

A Study on the Serial-Parallel Resonant DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 직.병렬 공진 DC/DC 컨버터에 관한 연구)

  • Hwang, Gye-Ho;Lee, Bong-Sub;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.31-40
    • /
    • 2008
  • Recently, Contactless Power Supply(CPS) system has been broadly studied as a power supply system for Flat Panel Display(FPD) material transfer equipments. In mass production line, CPS systems on material transfer equipment are applied only in the straight sections with single operating vehicle. The formal CPS system was not adequate for curved section nor multiple operating vehicles. Therefore, this paper presents CPS system that consists of straight and curved section with multiple operation vehicles. The circuit topology of CPS system consists of full bridge configured serial-parallel resonant DC/DC converter. The control method for CPS system consists of duty control method on the primary power supply system to maintain constant resonant current. And the secondary power supply systems of multiple vehicles are self controled to maintain constant output voltage. Practically, the test result of dual vehicles on straight and curved section of material transfer equipments were satisfactory, and proved it's applicability on commercial use.

Cell Disruption of Dunaliella salina using Batch Low Frequency Non-Focused Ultrasound (비집속 회분저주파를 이용한 Dunaliella salina 세포 파쇄)

  • Choi, Jun-Hyuk;Kim, Gwang-Ho;Park, Jong-Rak;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.63-71
    • /
    • 2021
  • Using fossil fuels in existing industrial systems causes a variety of social problems. Recently, many studies have been conducted on bio-refineries, which aim to actively utilize biomass to reduce the use of fossil fuels and solve various social problems. Among them, research using microalgae as a third-generation biomass has attracted considerable attention. Microalgae use inorganic matter to produce organic matter, and cell destruction is necessary to extract useful organic materials from microalgae. The extracted organic materials are currently used in various industrial fields. Numerous cell-destruction methods exist. We have investigated cell disruption by sonication, especially its efficiency. Ultrasound is a sound wave with frequencies above 20 kHz, and destroys cells by sending high energy through a cavitation that occurs, according to the characteristics of the sound wave. The Dunaliella salina microalgae used in this study was cultured in a flat-type photobioreactor. Experiments were performed using a batch low-frequency processing device. Logistic model was applied to analyze the results of cell-destruction experiments using ultrasound. The proper conditions for the most efficient cell destruction were OD 1.4(microalgae concentration)), 54watt(output power) and 200mL(microalgae capacity).

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Millimeter-wave Broadband Amplifier integrating Shunt Peaking Technology with Cascode Configuration (Cascode 구조에 Shunt Peaking 기술을 접목시킨 밀리미터파 광대역 Amplifier)

  • Kwon, Hyuk-Ja;An, Dan;Lee, Mun-Kyo;Lee, Sang-Jin;Moon, Sung-Woon;Baek, Tae-Jong;Park, Hyun-Chang;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.90-97
    • /
    • 2006
  • We report our research work on the millimeter-wave broadband amplifier integrating the shunt peaking technology with the cascode configuration. The millimeter-wave broadband cascode amplifier on MIMIC technology was designed and fabricated using $0.1{\mu}m\;{\Gamma}-gate$ GaAs PHEMT, CPW, and passive library. The fabricated PHEMT has shown a transconductance of 346.3 mS/mm, a current gain cut off frequency ($f_T$) of 113 GHz, and a maximum oscillation frequency ($f_{max}$) of 180 GHz. To prevent oscillation of designed cascode amplifier, a parallel resistor and capacitor were connected to drain of common-gate device. For expansion of the bandwidth and flatness of the gain, we inserted the short stub into bias circuits and the compensation transmission line between common-source device and common-gate device, and then their lengths were optimized. Also, the input and output stages were designed using the matching method to obtain the broadband characteristic. From the measurement, we could confirm to extend bandwidth and flat gain by integrating the shunt peaking technology with the cascode configuration. The cascode amplifier shows the broadband characteristic from 19 GHz to 53.5 GHz. Also, the average gain of this amplifier is about 6.5 dB over the bandwidth.