• Title/Summary/Keyword: flat joint

Search Result 174, Processing Time 0.019 seconds

Ductility of Column-Slab eoint in R/C Flat Plate System (플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구)

  • 김형기;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

Convergence Comparison of the Angle Change of Ankle Joint while Walking according to the Heel height of Insole Shoes in 20s males with Flatfoot (평발을 가진 20대 남성이 인솔구두의 굽 높이에 따른 보행 시 발목관절의 각도변화에 대한 융복합적 비교)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Kim, Hyen-Ae
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.117-123
    • /
    • 2021
  • The purpose of this study is to convergence comparison the ankle joint angle change during walking of college students in their 20s with flat foot according to the heel height of insole shoes. Qualisys Track Manager Software ver. 2.8 (Qalisys Track Manager) was used for 15 college students. Functional shoes with insoles were manufactured, and the heel heights of the shoes were set to 3cm and 7cm. The subjects wore shoes with two high heels and gaited by attaching a reflex marker to the side of the ankle joint. The angle change of the ankle joint was measured in the gait stance phase. The angle of the ankle joint significantly decreased both heel strike, foot flat, midstance, and toe off to the heel height increased when the subjects with flat feet wore insole shoes. Therefore, it is thought that flat feet should wear low shoes when wearing insoles to reduce the fatigue of the soles and to walk comfortably.

Effects of Customized 3D-printed Insoles on the Kinematics of Flat-footed Walking and Running

  • Joo, Ji-Yong;Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.237-244
    • /
    • 2018
  • Objective: Flat-footed people struggle with excessive ankle joint motion during walking and running. This study aimed to investigate the effects of customized three-dimensional 3D-printed insoles on the kinematics of flat-footed people during daily activities (walking and running). Method: Fifteen subjects (height, $169.20{\pm}2.61cm$; age, $22.87{\pm}8.48years$; navicular bone height, $13.2{\pm}1.00mm$) diagnosed with flat feet in a physical examination participated in this study. Results: The customized 3D-printed insoles did not significantly affect 3D ankle joint angles under walking and running conditions. However, they shifted the trajectory of the center of pressure (COP) laterally during fast walking, which enhanced the load distribution on the foot during the stance phase. Conclusion: The customized 3D-printed insoles somewhat positively affected the pressure distribution of flat-footed people by changing the COP trajectory. Further research including comparisons with customized commercial insoles is needed.

The Relationship Between the Range of Hip Rotation and the Quadriceps Angle in Subjects With and Without Flat Foot

  • Lee, Keun-hyo;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • Background: Alignment of the lower limb is an important factor, influencing balance and gait in kinematics and kinetics, in patients with and without a flat arched foot. Flat arched foot are associated with the range of motion (ROM) of the hip and alignments of the knee joints, is strongly influenced. Objects: The purpose of this research was to investigate the relationship between hip joint ROM and quadriceps angle (Q-angle), by dividing them into two groups according to the presence or absence of flat feet, using a navicular drop test (NDT) and resting calcaneal stance position (RCSP). Methods: Forty elderly patients were allocated to the experimental group (flat foot group, n1=20) or the control group (non-flat group, n2=20). Universal and digital goniometer, tractograph and tape measure were used to determine the related changes in the hip ROM, Q-angle, NDT and RCSP. Results: Data were analyzed using the Pearson correlation coefficients. Active internal ROM of the hip joint (right, r=.803, p<.001), (left, r=.951, p<.001) were highly correlated with NDT, and also, was moderately correlated with Q-angle (right, r=.562, p=.019), (left, r=.757, p<.001). Passive internal ROM of the hip joint (right, r=.742, p=.001), (left, r=.922, p<.001) were highly correlated with NDT, and also, was moderately correlated with RCSP (right, r=-.530, p=.029) and with Q-angle (right, r=.710, p=.001), (left, r=.698, p=.002) in the flat foot group. However, no strong correlation among the hip ROM, NDT, RCSP and Q-angle were found in the non-flat foot group. Conclusion: This research may provide evidence of the correlations between hip internal ROM and flat foot.

Estimation of Bolted Joint Strength of Flat Plate of Glass-Mat Reinforced Thermoplastics (GMT 평판의 볼트조인트 강도 평가)

  • Kang, Wan-Seok;Min, Ji-Hyun;Lee, Jae-Wook;Im, Yong-Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1636-1643
    • /
    • 2003
  • In this study, bolted joint made of Glass-Mat Reinforced Thermoplastics (GMT) specimen was under tensile loading to investigate the relation between joint strength and glass-fiber weight fraction of the flat plate specimen. The effect of molding conditions such as the initial size of a GMT charge and molding temperatures was investigated under plane strain condition. In consideration of the specimen geometry, minimum end distance and width of the specimen to induce the bearing fracture mode of the bolted joint were determined. And finally, the effect of the outer diameter of washer and clamping pressure on joint strength was also investigated. Since joint strength is dependent on the local glass-fiber weight fraction, experimentally measured strength was modified, considering its irregular values of the specimen molded under various processing conditions in order to obtain a reasonable correlation between the two.

The Comparison Study of Ankle Joint Mobilization and Elongation on the Difference of Weight-bearing Load, Low Back Pain and Flexibility in Flat-foots Subjects (편평족에 대한 관절가동술과 자가신장이 요부의 신장성, 요통과 하지 체중부하 차이에 대한 비교 연구)

  • Park, Sung-doo;Yu, Dal-yeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • Background: The purpose of this study was to investigate the relationship between the spine and the flat-foot, the stability and the alignment of the posture of the neck to prevent the alignment of the ankle joint operation and the lower back flexibility of the lumbar region according to the type of treatment using active stretching of the triceps, back pain, and to see how they affect weight bearing differences. Methods: The subjects of this study were 24 chronic low back pain patients. They were randomly divided into experimental group and control group. In the experimental group, ankle joint mobilization and active scraping of triceps were performed three times a week for a total of 6 weeks. The control group was performed in the same way without articulation. The range of flexion and extension motion of the lumbar spine and pain degree and difference of weight-bearing were measured before and after the experiment. Results: The model of ankle joint mobilization and calf muscle elongation of flat foot significantly improved the range of flexion and extension motion of the vertebrae (p<.05) and the VAS and distribution of weight-bearing were decreased in both of two groups (p<.05). In other words, the exercise and mobilization help to recover of the balance of the whole musculoskeletal, the vertebrae. Conclusions: The active exercise of the triceps muscle of the lower leg in this study It affects the flexibility of the lumbar spine, the pain and the difference in the weight support of the lower extremities, when we performed ankle joint mobilization for exercise and cramping, pain and the difference in weight support between the two lower limbs.

  • PDF

Analysis of Backside Temperature according to Joint and Installation Types of Mortar with Oyster Shells (굴 패각을 혼입한 모르타르의 접합방식 및 설치 형태에 따른 이면온도 분석)

  • Kim, Hae-na;Hong, Sang-Hun;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.37-38
    • /
    • 2023
  • The purpose of this study is to manufacture mortars incorporating oyster shells and install them in the form of shaped, shaped butt joints, and flat boards to see what difference there is in the back temperature depending on the joint method and the type of installation. Based on the fact that similar backside temperatures were measured regardless of the presence or absence of a joint It is judged that the joint will not affect the backside temperature if it is constructed closely, In the case of ㄱ shaped, it is believed that the backside temperature higher than the backside temperature of the flat board was measured because heat accumulates on the backside during heating.

  • PDF

Investigate the Effect of Arch Support Stiffness on Gait Characteristics in Men with Flexible Flat Feet - A Focus on the Ankle Joint - (유연성 평발인 남성의 보행 시 족궁지지대의 강도가 보행특성에 미치는 영향 - 발목관절을 중심으로 -)

  • Park, Subin;O'Sullivan, David Michael;Lee, Jungho
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • Objective: The aim of this study is to analyze the effect of the strength of the ankle support on the walking characteristics and ankle joints when men with flexible flat feet walk. Method: 13 adult male subjects (age: 23.9 ± 2.4 yrs, height: 173.0 ± 5.0 cm, weight: 76.9 ± 13.2 kg, Navicular Drop Test (NDT): 10.2 ± 0.8 mm) participated in this study. Each participant had to walk with the 3 conditions, barefoot, soft arch support and hard arch support, along a walkway while their kinematics was recorded at 100 Hz. Results: Based on the results of this study, it is considered that men with flexible flat feet should use hard arch support rather than bare feet to induce normal arch shape, relieve foot damage caused by excessive ankle joint abnormalities and improve stability. Conclusion: Our results for men with flat flexibility, there was a significant difference in the value of step length when walking was performed using two arch supports with different strengths. The angle of ankle dorsiflexion was significantly increased, and the ankle eversion angle was significantly decreased.

Differences in the Joint Movements and Muscle Activities of Novice according to Cycle Pedal Type

  • Seo, Jeong-Woo;Kim, Dae-Hyeok;Yang, Seung-Tae;Kang, Dong-Won;Choi, Jin-Seung;Kim, Jin-Hyun;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.237-242
    • /
    • 2016
  • Objective: The purpose of this study was to compare the joint movements and muscle activities of novices according to pedal type (flat, clip, and cleat pedal). Method: Nine novice male subjects (age: $24.4{\pm}1.9years$, height: $1.77{\pm}0.05m$, weight: $72.4{\pm}7.6kg$, shoe size: $267.20{\pm}7.50mm$) participated in 3-minute, 60-rpm cycle pedaling tests with the same load and cadence. Each of the subject's saddle height was determined by the $155^{\circ}$ knee flexion angle when the pedal crank was at the 6 o'clock position ($25^{\circ}$ knee angle method). The muscle activities of the vastus lateralis, tibialis anterior, biceps femoris, and gastrocnemius medialis were compared by using electromyography during 4 pedaling phases (phase 1: $330{\sim}30^{\circ}$, phase 2: $30{\sim}150^{\circ}$, phase 3: $150{\sim}210^{\circ}$, and phase 4: $210{\sim}330^{\circ}$). Results: The knee joint movement (range of motion) and maximum dorsiflexion angle of the ankle joint with the flat pedal were larger than those of the clip and cleat pedals. The maximum plantarflexion timing with the flat and clip pedals was faster than that of the flat pedal. Electromyography revealed that the vastus lateralis muscle activity with the flat pedal was greater than that with the clip and cleat pedals. Conclusion: With the clip and cleat pedals, the joint movements were limited but the muscle activities were more effective than that with the flat pedal. The novice cannot benefit from the clip and cleat pedals regardless of their pull-up pedaling advantage. Therefore, the novice should perform the skilled pulling-up pedaling exercise in order to benefit from the clip and cleat pedals in terms of pedaling performance.

Mechanical Property of Liquid Phase Diffusion Bonded Joint of Rene80/B/Rene80 (Rene 80/B/Rene 80 액상 확산접합부의 기계적 성질)

  • 정재필;강춘식
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.125-133
    • /
    • 1995
  • Rene80 superalloy was liquid phase diffusion bonded by using pure boron (B) as an insert material. As a basic study for the possibility of practical application of this bonding method, hardness and high temperature tensile strength of the bonded joint and metallurgical analysis were investigated. As experimental results, hardness of the bonded joint was homogenized after bonding and the tensile strength at 1144K was obtained to 90% of that of base metal. But there were some problems to be improved also, that means the joint was hardened after bonding due to increase of B content and elongation was much lower than that of base metal. Flat area and (Mo, Cr, W) boride, which should be harmful for bonding strength, were observed on the fractured surface of the tensile tested specimen.

  • PDF