• 제목/요약/키워드: flashover voltage

검색결과 162건 처리시간 0.021초

연소화염이 플래시오버 특성에 미치는 영향 (The Influence of Flashover Characteristics Caused by Combustion Flames)

  • 김인식;김이국;박재용;이상우;김충년;지승욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.193-197
    • /
    • 2001
  • In this paper, reduction characteristics of the ac flashover voltage in the horizontal air gap of sphere-sphere and needle-needle electrode system were investigated when the combustion flame was present near the high-voltage electrodes. The reduction characteristics of ac flashover voltage were discussed with thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that changed by the corona wind and coulomb's force. As the results of an experimental, It was found that the reduction of flashover voltage in sphere-sphere system, in comparison with the no-flame case, are 79.9 [%] for k=0, 82.9 [%] for k=0.5, 87.5 [%] for k=1.0, 85.0 [%] for h=0 [cm], 40.8 [%] for h=5 [cm] and 28.2 [%] for h=9 [cm] when ac voltage is applied.

  • PDF

선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성 (Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

구-구갭의 섬락 특성에 미치는 연소화염의 영향 (Influence of the Combustion Flames on the Flashover Characteristics of the Sphere-Sphere Air Gap)

  • 김인식;이상우
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.44-51
    • /
    • 2005
  • 본 연구에서는 구-구갭을 수평 배치하였을 때, 연소화염에 의한 교류 및 직류 플래시오버전압 특성을 조사하였다. 화염에 의한 플래시오버 극성을 조사하기 위해 전압 및 전류파형을 측정하였으며, 플래시오버가 발생되기 전에 쿨롱력에 의한 화염의 형상 변화를 관찰하였다. 또한 플래시오버 전압의 저하 요인으로서 상대공기밀도의 저하 및 연소화염의 열전리 영향에 대해 고찰하였다. 실험 결과, 구-구갭에서 접지측 전극과 갭길이의 비를 k라고 할 때, 화염위치 k:0(접지측), k=0.5(중앙부) 및 k=1.0(전원측)인 경우 화염에 의한 교류 섬락전압의 평균값은 화염이 없을 때에 비해 각각 79.9, 82.9 및 $87.5[\%]$ 저하되었으며, 또한 화염의 높이 h=0, h=5 및 h=9[cm]일 때 교류 플래시오버 전압의 평균값은 화염이 없는 경우를 기준으로 하였을 때 각각 85.0, 40.8 및 $28.2[\%]$ 저하되었다. 소규모 연소화염에서의 열전리 영향은 크지 않는 것으로 나타났다.

연면섬락특성의 한 개선방법에 대한 실험적 고찰 (Experimental consideration on some method of improving surface flashover discharge characteristics)

  • 정성계;이계호;김원섭
    • 전기의세계
    • /
    • 제18권2호
    • /
    • pp.21-25
    • /
    • 1969
  • This paper shows experimentally the characteristics of raising up the flashover voltage in supension insulators or bushing according to the theoretical results which was gotten by previous study. It was shown theoretically that, if some conducting metallic barriers are inserted into the flashover discharge path, the flashover voltage is found to be increased considerably. In order to verify this theoretical results, some basic experimental study was done, and the results was found to be more or less satisfactory except some problems which must be considered in future study.

  • PDF

송전선로용 폴리머 피뢰기의 직렬공극 특성 (Series-Gap Characteristics of Polymeric Arrester for Transmission Line)

  • 조한구;유대훈;이용순;김종채
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Rotating Wheel Dip Test에 의한 에폭시 절연재료의 내트래킹성과 열화 특성 (Tracking Resistance and Aging Characteristics of Epoxy Insulating Materials by the Rotating Wheel Dip Test)

  • 조한구
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.530-537
    • /
    • 2008
  • This paper describes the results of a study on the tracking performance of outdoor insulating materials based on the rotating wheel dip test(RWDT). And, the influence of surface degradation was evaluated through such as measurement of the flashover voltage after and before tracking test, also aspects of surface degradation using scanning electron microscopy. The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler, the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage, despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same.

연면방전에 미치는 도전층의 영향 및 그 애자, 투관에의 응용에 관한 연구 (A Study on the Effects of Metallic Barriers on Surface Discharge and It's Application to Insulators and Bushings)

  • 정성계
    • 전기의세계
    • /
    • 제19권2호
    • /
    • pp.1-5
    • /
    • 1970
  • According to the previous studies which was done by the author, the flashover voltage was found to be increased considerably if some metallic barriere are inserted into the flashover discharge path. This paper shows that the flashover voltage in suspension insulators and bushings is raised up by the application of metallic barrier effect on surface discharge. Using moderate metallic barrier configulation the flash over voltage can be raised up by the amount of about 15% compared to that of the convensional type of suspension insulatiors and bushings.

  • PDF

Dry Air 중의 준평등전계에서 노점과 고체절연물 재질에 따른 수평연면방전 특성 연구 (A Study of Horizontal Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials of Solid Insulator in Quasi-Uniform Field)

  • 강병칠;석정후;민경준;배성우;이광식;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.64-69
    • /
    • 2015
  • This study investigates the Horizontal surface discharge characteristics of solid insulators by varying their materials, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polyethlene and polyurethane. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polyethlene is higher than that of polyurethane. Moreover, it is observed that the flashover voltage increases as the horizontal distance between the electrodes of each solid insulator become larger, respectively. However, as the pressure is increased, flashover voltage of the solid insulators is saturated. Therefore, selection of cost-effective insulation is needed in order to appropriate pressure.

준평등전계에서의 Dry-Air 노점과 고체절연물 재질 및 형상에 따른 연면방전 특성 연구 (A Study of Surface Discharge Characteristics for Dew-Point of Dry-Air and Materials or Shapes of Solid Insulator in Quasi-Uniform Field)

  • 민경준;강병칠;임동영;이광식;박원주
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.44-49
    • /
    • 2013
  • This study investigates the surface discharge characteristics of solid insulators by varying their materials, their shapes, and the dew-point of dry-air. The methodology of this study is that a quasi-uniform field is first applied to a test chamber. Then, the chamber is filled with dry-air as an insulation gas which pressure is varied from 1 to 6atm while applying an AC voltage to the chamber. The used solid insulators are teflon, polycarbonate, and bakelite. As the dew-point is lower and the pressure of dry-air is higher, the flashover voltage of all solid insulators increases more. When each characteristic of the solid insulators is compared under the same gas pressure, the flashover voltage of teflon is the highest. Then, the flashover voltage of polycarbonate is higher than that of bakelite. Moreover, it is observed that the flashover voltage increases as the diameter and the thickness of each solid insulator become larger and thicker, respectively. However, the thickness of the solid insulators is more critical for increasing the flashover voltage than their diameter.

N2/O2 혼합가스 중 적층된 고체유전체에 대한 연면방전의 메커니즘과 특성 (Mechanism and Characteristics of the Surface Flashover on the Laminated Solid Dielectric in N2/O2 Mixture Gas)

  • 임동영;최은혁;최상태;배성우;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.32-39
    • /
    • 2015
  • This paper presents the surface flashover mechanism of a laminated solid dielectric and describes the surface flashover characteristics with the inherent capacitance of the laminated solid dielectric in a $N_2/O_2$ mixture gas (8:2) under an quasi uniform field. It was found that the electron emission at a cathode and the high-local electric field region around an anode were important factors to reasonably describe the surface flashover mechanism. The surface flashover voltage by the mechanism decreased with the inherent capacitance increase of the laminated solid dielectric. In addition to the surface flashover mechanism and its characteristics, the surface flashover voltage equations as a function of the inherent capacitance were derived by considering a gas pressure used in future eco-friendly GIS and the factors influencing the surface flashover.