• Title/Summary/Keyword: flammable

Search Result 509, Processing Time 0.024 seconds

An Experimental Study on Improvement of Fire Extinguishing Performance of Basic Sprinkler System (간이스프링클러 설비의 소화성능 향상에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.46-51
    • /
    • 2018
  • A basic sprinkler system is a fire extinguishing system that can be easily installed in a fire-vulnerable place such as a publicly used establishments. However, the publicly used establishments are not only complicated in structure, but also have a large amount of flammable interior materials, and the users are not normally in a normal state, which is a very dangerous fire-fighting object. Therefore, due to the low fire extinguishing performance of the basic sprinkler system installed in the publicly used establishments, the fire suppression control can not be performed quickly in case of fire, which may increase the life and property damage. In this study, the cases of quantitative changes of extinguishing water used in basic sprinkler system and the cases of addition of additives such as wetting agents, reinforced agents to improve extinguishing performance were compared. Experimental results showed that the extinguishing performance was improved as the quantity of extinguishing water increase and the reinforced agents showed similar performance to that of 60% increase in the amount of extinguishing water. The cooling time to $200^{\circ}C$ and oxygen concentration were improved up to 14.3% and 34.5%, respectively. In the case of using the wetting agent, the cooling time to $200^{\circ}C$ and oxygen concentration did not show any significant improvement, but showed the effect of preventing deep seated fire. In order to prevent loss of life and property, it is necessary to improve the performance of the basic sprinkler system by increasing amount of extinguishing water or using additives like reinforced agents.

Spectral Analysis Method for Classification of Liquid Characteristics (액체의 특성 분류를 위한 스펙트럼 분석 방법)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2206-2212
    • /
    • 2016
  • It is necessary to find characteristic phenomena related with permittivity differences for classification of liquid characteristics. If these phenomena can be remotely detected and characteristics can be extracted, it will be very useful in finding flammable liquid materials and classifying substances of these liquids. Therefore, in this paper, reflection and transmitted signals were analyzed from three receiving antennas with one transmitting antenna using wideband electromagnetic wave signals. Frequency response characteristics of reflected or transmitted signals are different according to characteristics of liquid materials. However, conventional FFT methods cannot be applied due to problems of low resolution caused by data windowing distortion. To minimize these problems, eigenvector analysis method was applied for high resolution spectrum estimation of received signals. From these results, it can be shown that classification of many kinds of liquids are possible using peak frequencies and corresponding peak power values of spectrum estimates obtained from various liquid materials.

An Experimental Study on the Development of Lightweight Foamed Concrete as Sandwich Panel Core (샌드위치 패널 심재용 경량기포콘크리트 개발에 관한 실험적 연구)

  • Lee, Sang-An;Chun, Woo-Young;Ko, Kwan-Ho;Kim, Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.557-560
    • /
    • 2008
  • This was done by analyzing the sandwich panels that are now widely used in construction work. Sandwich panels are used for diverse purposes in construction work worldwide. In Korea, polystyrene panels that have organic materials as their core material are used. These panels are thus very vulnerable to fire, with risks of core melting, sheet deformation, and hazardous gases. Accordingly, sandwich panels' fire-resistant or non-flammable properties must be secured. To solve these problems, the optimal mixing proportion of lightweight foamed concrete for the sandwich panel core was determined. A new method of doing this was introduced that is completely different from the existing method, wherein a foaming agent is added to realize lightweight concrete. For lightweight concrete, the foaming mechanisms via diverse chemical reactions were identified, H$_2$O$_2$ was added for heating in the reaction, and the concrete foaming was maximized. Through diverse experiments to determine the optimal mixing proportion of lightweight foamed concrete and to examine the filling characteristic of lightweight foamed concrete for sandwich panel cores using waste materials, the physical and mechanical properties of lightweight foamed concrete were examined.

  • PDF

An Experimental Study on the Performance and Emission Characteristics with Hydrogen Enrichment in a CNG Engine (수소첨가 CNG기관의 성능 및 배출가스 특성에 관한 실험적 연구)

  • Ryu, Kyuhyun;Kim, Ingu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.164-169
    • /
    • 2015
  • Recent research has focused on alternative fuel to improve engine performance and to comply with emission regulation. Finding an alternative fuel and reducing environment pollution are the main goals for future internal combustion engines. The purpose of this study is to obtain low-emission and high-efficiency by hydrogen enriched CNG fuel in SI engine and is to clarify the effects of hydrogen enrichment in CNG fuelled engine on exhaust emission and performance. An experimental study was carried out to obtain fundamental data for performance and emission characteristics of hydrogen enrichment in SI engine. The experiment was conducted at 2500 rpm, bmep 2 bar, 4 bar conditions while CNG fuel was mixed with 10, 20 and 30% hydrogen blends. From the experimental results, combustion duration was shortened due to rapid flame propagation velocity of hydrogen and these were attributed to the burning velocity increasing exponentially with increasing hydrogen blending ratio. Hydrogen has much wider flammable limit than methane, gasoline and the minimum ignition energy is about an order of magnitude lower than for other combustion. By adding hydrogen, $CO_2$ and HC were reduced. However, $NO_X$ was increased dut to high rate of heat release for hydrogen substitutions.

A Numerical Analysis of Hydrogen Diffusion for Hydrogen Leakage from a Fuel Cell Vehicle in a Long Road Tunnel (장대터널에서 수소연료전지 차량의 수소 누출에 대한 수소 거동의 수치해석 연구)

  • Choi, Jongrak;Hur, Nahmkeon;Lee, Moonkyu;Chang, Hyungjin;Lee, Kwangbum;Yong, Geejoong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.588-597
    • /
    • 2012
  • In the present study, the dispersion characteristics of hydrogen leakage from a Fuel Cell Vehicle (FCV) were analyzed by numerical simulation in order to assess the risk of a hydrogen leakage incident in a long road tunnel. In order to implement the worst case of hydrogen leakage, the FCV was located at the center of a tunnel, and hydrogen was completely discharged within 63 seconds. The Leakage velocity of hydrogen was adopted sub-sonic speed because that the assumption of the blockage effect of secondary device inside a vehicle. The temporal and spatial evaluation of the hydrogen concentration as well as the flammable region in a road tunnel was reported according to change of ventilation operating conditions. The hydrogen was blended by supply air form a ventilation fan, however, the hydrogen was discharged to outside in the exhaust air. It is observed that the efficiency way to eliminate of hydrogen is supply air operating condition under the hazardous hydrogen leaking incident. The present numerical analysis can be provided useful information of ventilation under the hydrogen leaking situation.

Fuzzy Based Failure Mode and Effect Analysis (FMEA) of Hydrogen Production Process Using the Thermococcus Onnurineus NA1 (퍼지기반 해양 미생물 이용 수소 제조 공정의 고장유형 및 영향분석)

  • PARK, SUNG HO;AHN, JUNKEON;KIM, SU HYUN;YOO, YOUNG DON;CHANG, DAEJUN;KANG, SUNGKYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.307-316
    • /
    • 2018
  • In this study, the failure mode and effect analysis (FMEA) of hydrogen production process by using the Thermococcus onnurineus NA1 was conducted and advanced methodology to compensate the weakness of previous FMEA methodology was applied. To bring out more quantitative and precise FMEA result for bio-hydrogen production process, fuzzy logic and potential loss cost estimated from ASPEN Capital Cost Estimator (ACCE) was introduced. Consequently, risk for releasing the flammable gases via internal leakage of steam tube which to control the operating temperature of main reactor was caution status in FMEA result without applying the fuzzification and ACCE. Moreover, probability of the steam tube plugging caused by solid property like medium was still caution status. As to apply the fuzzy logic and potential loss cost estimated from ACCE, a couple of caution status was unexpectedly upgraded to high dangerous status since the potential loss cost of steam tube for main reactor and decrease in product gases are higher than expected.

A Study on the Improvement of Methodologies for Establishing a Vulnerability Classification of Chemical Terrorism in Public Facilities (다중이용시설 화학테러 취약등급설정 방법론 개선에 대한 연구)

  • Joo, Sun Ho;Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.89-102
    • /
    • 2020
  • Chemical terrorism using toxic and flammable gases, which could be fatal to the health of the human body, poses a serious threat to the security of most advanced countries, as well as those that are suffering from local disputes, due to the asymmetric information that exists between terrorist actors and victims. The countermeasures against chemical terrorism can be roughly divided into three stages: prevention, response, and probation. The critical factors for each professional response agency, and the personnel that determine the degree and range of chemical terrorism damage, are performing missions successfully in the process of the prevention and the response stage against chemical terrorism. To do this, conducting objective and systematical assessments on facilities that could potentially be the subject of chemical terrorism is more important than anything. In this study, we compared the existing domestic and foreign vulnerable classification systems for chemical terrorism, reviewed the current direction of improvement in domestic classification systems, and suggested more scientific and systematic methodologies through the vulnerability assessment on an actual public facility sample.

반도체 및 Optic Industries 클린룸 배기가스의 오염제어 및 청정화기술

  • 황유성
    • Air Cleaning Technology
    • /
    • v.17 no.4 s.67
    • /
    • pp.39-57
    • /
    • 2004
  • 첨단산업으로 불리는 반도체, LCD, PDP, 유기EL(OLED) 등의 생산 공정은 고도의 청정상태를 요구하며, 때문에 이들의 생산공정 중 대부분이 클린룸 내에서 이루어진다. 클린룸 내에서의 주요공정은 크게 박막형성(Layering), 노광(Photo Lithography), 식각(Etching) 등 3가지 공정으로 나눌 수 있으며, 반도체 제조공정의 경우 특별히 도핑(Doping) 공정이 추가된다. 오염물질을 함유하는 클린룸 배기는 일반적으로 산, 알칼리, Toxic(PFCs, Flammable), VOC 등으로 분류하며, 각각의 배기는 각 배기특성에 맞는 오염제어 장치를 통해, 정화된 후, 대기로 방출된다. 산, 알칼리 배기는 일반적으로 최종 단계에서 중앙집중식 습식스크러버에 의해 흡수, 중화 처리되며, VOC의 경우 농축기(Concentrator) & 축열식 열 산화장치(RTO) 설비에 의해 연소 처리된다. 하지만 CVD공정으로부터의 배기가 주를 이루는 Toxic배기의 경우, 다량의 PFCs(과불소화합물) 가스를 함유하고 있는 이유로, 대부분 클린룸 내부에 P.O.U(Point of use) 처리장치가 설치되며, P.O.U에 의해 1차 처리된 후 최종적으로 중앙집중식 습식스크러버를 거쳐 대기로 방출된다. 알칼리배기의 주성분으로는 암모니아($NH_3$), HMDS (Hexa Methyl DiSilazane), TMAH (Tetra Methyl Ammonium Hydroxide), LGL, CD 등이며 흡수액에 황산(Sulfuric Acid)용액을 공급, 중화처리하고 있다. 탄소성분을 먹이로 하는 미생물의 번식에 의한 막힘 문제를 제외하고는 큰 문제가 없다. 하지만 Toxic배기 및 산배기의 경우 처리효율이, 가스흡수 이론에 의한 계산결과와 비교할 때, 매우 저조하게 나타나는 효율부족 현상을 겪고 있으며, 이는 잔여 PFCs 가스성분 및 반응에어로졸, 응축에어로졸 등의 영향으로 추정하고 있다. 최근 Toxic 배기의 경우, P.O.U 설비를 Burn & Wet type으로 변경하여, 배기 중 PFCs 및 반응에 에어로졸($SiO_2$)의 농도를 원천적으로 감소시키는 노력이 진행 중이다. 산배기의 경우, 산결로 현상에 의한, 응축에어로졸이 문제가 되고 있으나 내식열교환기(Anti-Corrosive Heat Exchanger), 하전액적스크러버 시스템(Charged Droplets Scrubber System), Wet ESP(Wet Electrostatic Procipitator) 등의 도입을 통해 문제해결을 위한 노력을 경주하고 있다.

  • PDF

Explosion Simulations for the Quantitative Risk Analysis of New Energy Filling Stations (신에너지 충전소의 정량적 위험성 평가를 위한 폭발 시뮬레이션)

  • Dan, Seung-Kyu;Park, Kyung-Jun;Kim, Tae-Ok;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.60-67
    • /
    • 2011
  • The interest about new and renewable energy is increasing to reduce the burden of problems by depletion of fossil fuels and air pollutions. For example, LNG/CNG and LPG are expected to be replaced, especially in transportation use, by HCNG mixture and DME-LPG mixture, respectively. Because these new energies are still flammable gases, it is not inherently safe from the explosion. In this research, the quantitative risk analysis for using alternative mixtures in existing recharging facilities has been studied by using three types of explosion models (TNT equivalency model, PHAST and CFD-based FLACS) to manage the risk effectively. The differences of results by models were compared against, and the practical ways of when and how to use these models were suggested. It was also predicted that conventional gas filling stations would be converted as new energy stations without additional explosion risk.

Safety Assessment of By-product Gas Piping after Design Change (부생가스 연료배관의 설계변경에 따른 안전성 평가)

  • Yoon, Kee Bong;Nguyen, Van Giang;Nguyen, Tuan Son;Jeong, Seong Yong;Lee, Joo Young;Kim, Ji Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.50-58
    • /
    • 2013
  • Various process piping usually carries out high flammable and explosible gas under high pressure and high temperature. Due to frequent change of design and structure it becomes more complicated and compactly located. The safety management level is relatively low since it is considered as simply designed component. In this study a safety assessment procedure is proposed for complicated piping system around a mixing drum in which natural gas and by-product gases were mixed. According to ASME code, pipe stress analysis was conducted for determining design margin at some key locations of the piping. These high stress locations can be used as major inspection points for managing the pipe integrity. Sensitivity analysis with outside temperature of the pipe and support constraint condition. Possible effect of hydroen gas to the pipe steel during the previous use of the by-product gas was also discussed.