• Title/Summary/Keyword: fixed plate

Search Result 489, Processing Time 0.025 seconds

Dynamic Characteristic Analysis of Active Gurney Flap Considering Rotational Effect (회전 효과를 고려한 Active Gurney Flap 의 동특성 해석)

  • Kee, YoungJung;Kim, TaeJoo;Kim, DeogKwan
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • In this study, the finite element analysis was carried out to investigate dynamic characteristics of the AGF(Active Gurney Flap) which is under development for reducing vibration and noise of the helicopter rotor system. The Gurney flap is a kind of small flat plate, mounted normal to the lower surface of the airfoil near to the trailing edge. An electric motor, L-shaped linkages and flap parts were integrated into a rotor bade, and 3~5/rev control was given to the AGF to reduce the vibration in the fixed frame. Thus, an explicit time integration method was adopted to investigate the dynamic response of the AGF with considering both centrifugal force due to the rotor rotation and active control input, and it can be seen that the vertical displacement of the AGF was satisfied to meet the design requirement.

Study on Flow Characteristics and Discharge Coefficient of Safety Valve for LNG/LNG-FPSO Ships (LNG / LNG-FPSO 선박용 안전밸브의 유동특성 및 유출계수에 관한 연구)

  • Kim, Sung-Jin;Jung, Sung-Yuen;Kim, Dang-Ju;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.487-494
    • /
    • 2011
  • The safety valve used in LNG/LNG-FPSO ships plays an important role in maintaining a fixed level of pressure by emitting LNG gas out of the pipes in the LNG piping system. The discharge coefficient is regarded as the most important factor in the valve performance. To satisfy the ship's classification, the discharge coefficient of the safety valve must usually be over 0.8. Despite the importance of understanding the flow phenomena inside the safety valve, the valve design is usually based on experience and experiments. We carried out a computational fluid dynamics (CFD) investigation using the ANSYS-CFX software. We observed the flow phenomena inside the valve and measured the discharge coefficients according to changes in the valve lift, which is the distance between the exit of the nozzle and the lower part of the disc plate. We verified our CFD results for the discharge coefficients using available experimental data.

Design of Multiband Repeater Antenna with Fire-Fighting Band for In-Building Mobile Communication (소방무선대역을 포함하는 인빌딩용 다중대역 중계기 안테나 설계)

  • Kim, Sung-Min;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.495-503
    • /
    • 2016
  • This paper proposes the design of multiband repeater antenna with fire-fighting band for in-building mobile communication. The proposed antenna is composed of a center monopole and 4 parasitic elements on a circular plate. In order to realize good reflection coefficients at the multiband, mutual coupling between 4 parasitic elements and center monopole antenna is considered. The important parameters such as distance between parasitic element and a center monopole, and each height of a center monopole and 4 parasitic elements are simulated to obtain good antenna characteristics at the multiband. The diameter of 4 parasitic elements and a center monopole was fixed to 10 mm for easy design and manufacturing. The measurement results of reflection coefficients, 2-D patterns and gain agreed well with their simulation ones.

Meridional Circulations in a Sliced Cylinder (기울어진 회전 원판에 의한 원통형 용기내의 자오면 유동의 크기에 관한 연구)

  • KIM Jae Won;LIM Hong Sick
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.52-57
    • /
    • 1996
  • Mixing is most important for developing an electric washer which transforms angular momentum from rotating solid wall to laundry clothes inside it. For magnification of this mixing effect, some inventions are introduced to washing machine system, i. e., washing plate, washing rod, and even for washing cap in a model of a Korean manufacture. However, the previous efforts show dissatisfaction up till now. In this paper, a triumph to enhance mixing effects to increase washing performance is presented and verified by numerical investigation. The present model to simulate a washing tub is the simple circular cylinder with two endwall disks which is completely filled with a viscous liquid. The present improvement is to change mounting position of a bottom disk of the model cylinder. Therefore, the aim of this work just proposes a new idea, which is numerically inspected, to a producer of washing machine, In detail, this invention is alternating the mounting position of a rotating bottom disk. Actually skewed pulsator is placed in steady of a flat disk, so the two endwall disks at top and bottom are not in parallel. The angle between an inclined bottom disk and the horizontal plane is fixed as 5 degree and physical domain to consider poses a sliced cylinder. Flow fields in both a right circular cylinder and the present improved model are fully depicted by numerical integration on a body fitted nonorthogonal regular uniform grid system. Numerical data to explain flow structure are plotted for understanding of the effects of the inclined disk. Also enhanced mixing effects by the inclined rotating disk are gauged by accurate numerical data used in this work.

  • PDF

Image Stitching Using Normalized Cross-Correlation and the Thresholding Method in a Fluorescence Microscopy Image of Brain Tumor Cells (정규 상호상관도 및 이진화 기법을 이용한 뇌종양 세포의 형광 현미경 영상 스티칭)

  • Seo, Ji Hyun;Kang, Mi-Sun;Kim, Hyun-jung;Kim, Myoung-Hee
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.979-985
    • /
    • 2017
  • This paper, which covers a fluorescence microscopy image of brain tumor cells, looks at drug reactions by treating different types and concentrations of drugs on a plate of $24{\times}16$ wells. Due to the limitation of the field of view, a well was taken into 9 field images, and each has an overlapping area with its neighboring fields. To analyze more precisely, image stitching is needed. The basic method is finding a similar area using normalized cross-correlation (NCC). The problem is that some overlapping areas may not have any duplicated cells that help to find the matching point. In addition, the cell objects have similar sizes and shapes, which makes distinguishing them difficult. To avoid calculating similarity between blank areas and roughly distinguishing different cells, thresholding is added. The thresholding method classifies background and cell objects based on fixed thresholds and finds the location of the first seen cell. After getting its location, NCC is used to find the best correlation point. The results are compared with a simple boundary stitched image. Our proposed method stitches images that are connected in a grid form without collision, selecting the best correlation point among areas that contain overlapping cells and ones without it.

A Method Estimating Displacement using Measured Strain Response of Simply Supported Girder Bridges (단순지지 거더교의 실측 변형률 응답을 이용한 변위 추정 방법)

  • Jeon, Jun-Chang;Lee, Hee-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.18-24
    • /
    • 2016
  • This study presents a simple method which can estimate displacement using measured strain response of simply supported girder bridges. The basic concept of the present method is derived from a relation between displacement and strain, and is generalized by introducing analytical tool. Static and dynamic laboratory test are conducted on simply supported plate which is designed to respond dynamically similar to actual bridges to experimentally verify the present method, and displacement and strain are measured at the midpoint of specimen. Displacement estimated by using measured strain is well agreed with measured one. This study demonstrates that the present method is suitable for estimating displacement of real simply supported bridge, in which the installation of a displacement transducer at the fixed reference point is difficult.

Tissue engineering of dental pulp on type I collagen

  • Lee, Gwang-Hee;Huh, Sung-Yoon;Park, Sang-Hyuk
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.370-377
    • /
    • 2004
  • The purpose of this study was to regenerate human dental pulp tissues similar to native pulp tissues. Using the mixture of type I collagen solution, primary cells collected from the different tissues (pulp, gingiva, and skin) and NIH 3T3 ($1{\;}{\times}{\;}10^5{\;}cells/ml/well$) were cultured at 12-well plate at $37^{\circ}C$ for 14 days. Standardized photographs were taken with digital camera during 14 days and the diameter of the contracted collagen gel matrix was measured and statistically analyzed with student t-test. As one of the pulp tissue engineering, normal human dental pulp tissue and collagen gel matrix cultured with dental pulp cells for 14 days were fixed and stained with Hematoxyline & Eosin. According to this study, the results were as follows: 1. The contraction of collagen gel matrix cultured with pulp cells for 14 days was significantly higher than other fibroblasts (gingiva, skin) (p < 0.05), 2. The diameter of collagen gel matrix cultured with pulp cells was reduced to 70.4% after 7 days, and 57.1% after 14 days. 3. The collagen gel without any cells did not contract, whereas the collagen gel cultured with gingiva and skin showed mild contraction after 14 days (88.1% and 87.6% respectively). 4. The contraction of the collagen gel cultured with NIH 3T3 cells after 14 days was higher than those cultured with gingival and skin fibroblasts, but it was not statistically significant (72.1%, p > 0.05). 5. The collagen gel matrix cultured with pulp cells for 14 days showed similar shape with native pulp tissue without blood vessels. This approach may provide a means of engineering a variety of other oral tissue as well and these cell behaviors may provide information needed to establish pulp tissue engineering protocols.

Analysis on Response Characteristics of a Flexible Net Sheet in Waves (파랑중 유연한 그물망의 응답특성 해석)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.2
    • /
    • pp.89-96
    • /
    • 2012
  • Based on the hydroelastic theory and the matched eigenfunction expansion method(MEEM), the dynamic behavior of the porous flexible net sheet and wave forces have been investigated in monochromatic waves. The net sheet is installed vertically with the submergence depth. Top end of a net sheet is fixed and its lower end is attached by a clump weight. It is assumed that the initial tension is sufficiently large so that the effects of dynamictension variation can be neglected. The boundary condition on the porous flexible net sheet is derived based on Darcy's fine-pore model and body boundary condition. The developed analytic model can be extended to the impermeable/permeable vertical plate and the impermeable flexible membrane. The analytical model was used to study the influence of design parameters(wave characteristics, porosity, submergence depth, initial tension) on the response characteristics and wave load of the net sheet.

Combined Surgical and Orthodontic Treatment of Bimaxillary Dento-Alveolar Protrusion: A Report of Case (전방부분절 골절단술에 의한 상하악 전돌증의 악교정 1 예)

  • Byun, Sang-Kil;Lee, Hee-Keung;Jin, Byung-Rho;Oh, Meung-Chull;Kim, Tae-Joo;Kim, Young-Jun
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.271-279
    • /
    • 1985
  • The authors treated a case of bimaxillary dentoalveolar protrusion corrected by anterior segmental osteotomies: As presurgical treatment & process, closing of the upper anterior spacing with fixed appliances was worked out, cephalometric predicition & model surgery was done, and fabrication of intra-arch acrylic resin splints were made. It was not necessary to make an intermaxillary fixation with wire after surgery. Only intramaxillary fixation of anterior retracted mobile segment with resin plate was required for 8 weeks. After surgical treatment, leveling of the upper and lower arch with rectangular arch wire were accomplished as the Intrusion of anterior teeth proceeded. We will continue to improve the class II molar relationship by using class II elastics and have a good occlusiion through the orthodontic treatment.

  • PDF

Forehead Reconstruction with Hydroxyapatite Cement(MimixTM) and the Check Framework (Hydroxyapatite Cement(MimixTM)와 격자틀을 이용한 전두부 재건술)

  • Cho, Hyun Woo;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.219-222
    • /
    • 2008
  • Purpose: The purpose of this study is to develop hydroxyapatite cement simplified procedures for reconstruction of craniofacial deformities. Due to its expense and characteristics of quick hardening time, it may be inappropriate for forehead reconstruction or augmentation. Therefore we hear by introduce a more precise, easy and cheap method. The authors report forehead reconstruction with hydroxyapatite cement for a patient who suffered from craniofacial deformity. Methods: Case report and literature review. Results: A 35 year old man came to us with forehead and temporal area depression. He had a history of brain operations due to traumatic epidural hematoma. A physical exam showed an evidence of right side forehead weakness sign. Authors made RP model of his skull and applied check framework with Kirschner's wires for measuring accurate volume and contour on the depressed right side forehead area on the RP model. After complete exposure of defect area by bicoronary insicion, absorbable plate which applied on skull area was removed. Using three Kirschner's wires, authors made check framework on the right forehead lively and fixed with 2-hole miniplates on the boundary of the defect. After checking asymmetry, hydroxyapatite was applied on check shape framework just above Kirschner's wire. After removing Kirschner's wire, we corrected minimal unbalance and contour with bur. Conclusion: Check framework with Kirschner's wire was very convenient and cost saving methods for forehead reconstruction with hydroxyapatite cement.