• Title/Summary/Keyword: fixed plate

Search Result 489, Processing Time 0.028 seconds

p-Adaptive Mesh Refinement of Plate Bending Problem by Modified SPR Technique (수정 SPR 기법에 의한 휨을 받는 평판문제의 적응적 p-체눈 세분화)

  • Jo, Jun-Hyung;Lee, Hee-Jung;Woo, Kwang-Sung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.481-486
    • /
    • 2007
  • The Zienkiewicz-Zhu(Z/Z) error estimate is slightly modified for the hierarchical p-refinement, and is then applied to L-shaped plates subjected to bending to demonstrate its effectiveness. An adaptive procedure in finite element analysis is presented by p-refinement of meshes in conjunction with a posteriori error estimator that is based on the superconvergent patch recovery(SPR) technique. The modified Z/Z error estimate p-refinement is different from the conventional approach because the high order shape functions based on integrals of Legendre polynomials are used to interpolate displacements within an element, on the other hand, the same order of basis function based on Pascal's triangle tree is also used to interpolate recovered stresses. The least-square method is used to fit a polynomial to the stresses computed at the sampling points. The strategy of finding a nearly optimal distribution of polynomial degrees on a fixed finite element mesh is discussed such that a particular element has to be refined automatically to obtain an acceptable level of accuracy by increasing p-levels non-uniformly or selectively. It is noted that the error decreases rapidly with an increase in the number of degrees of freedom and the sequences of p-distributions obtained by the proposed error indicator closely follow the optimal trajectory.

  • PDF

The Physical Properties and Efficiencies of Cu(In,Ga)Se2 Thin Films Depending on the Mo:Na Thickness (Mo:Na 두께에 따른 Cu(In,Ga)Se2 박막의 물성과 효율변화)

  • Shin, Younhak;Kim, Myunghan
    • Korean Journal of Materials Research
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2014
  • To realize high-performance thin film solar cells, we prepared CIGS by the co-evaporation technique on both sodalime and Corning glass substrates. The structural and efficient properties were investigated by varying the thickness of the Mo:Na layer, where the total thickness of the back contact was fixed at 1${\mu}m$. As a result, when the Mo:Na thickness was 300 nm on soda-lime glass, the measured Na content was 0.28 %, the surface morphology was a plate-like compact structure, and the crystallinity by XRD showed a strong peak of (112) preferential orientation together with relatively intense (220) and (204) peaks as the secondary phases influenced crystal formation. In addition, the substrates on soda-lime glass effected the lowest surface roughness of 2.76 nm and the highest carrier density and short circuit current. Through the optimization of the Mo:Na layer, a solar conversion efficiency of 11.34% was achieved. When using the Corning glass, a rather low conversion efficiency of 9.59% was obtained. To determine the effects of the concentration of sodium and in order to develop a highefficiency solar cells, a very small amount of sodium was added to the soda lime glass substrate.

Electro-mechanical Properties of Piezoelectric Ceramic Bimorphs (압전 세라믹 바이모프의 전기기계적 특성)

  • Lee, Yong-Kuk;Lee, Hae-Ryong;Kim, Chang-Kyo;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1416-1418
    • /
    • 1994
  • Expressions for the displacement of a bimorph, one end fixed and the other free, has been introduced when sinusoidal inputs were applied to the ceramic plates on a thin metal plate. Maximum displacements at the free end and strains at the position of strain gage attached were measured when various wave forms, voltages, and frequencies were applied to the bimorph whose length is 6.6[cm], width 2.5[cm], and thickness 0.0365[cm]. Under the constant voltage ( $70[V_{peak}]$ ), the strains and the displacements at the free end were larger than the case of the sinusoidal input when the square wave was applied and were smaller when triangular wave. It was shown that the displacements at the free end and the strains of the gage position were increased as the applied voltage in the range of $30-90[V_{peak}]$ and effective length were increased. And it was also found that the resonant frequency of a bimorph was decreased as its effective length was increased, and that the displacements and the strains were maximum at the resonant frequency.

  • PDF

Optimal Design of Thrust Surface Oil Groove of a High Side Scroll Compressor (고압식 스크롤 압축기 스러스트 오일 그루브 최적 설계)

  • Kim, Hyun-Jin;No, Young-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.127-133
    • /
    • 2017
  • Performance analysis has been carried out on a high side scroll compressor that had a fixed scroll equipped with a circular oil groove on its thrust surface. Oil was supplied to the oil groove through an intermittent opening from a high pressure oil reservoir formed inside the orbiting scroll hub. Oil in the groove was then delivered to both suction and back pressure chambers by pressure differentials and viscous pumping action of the orbiting scroll base plate. Mathematical modeling of this oil groove system was incorporated into a main compressor performance simulation program for an optimum oil groove design. The study findings were as follows. Pressure in the oil groove can be controlled by changing its configuration and the oil passage area. With an enlarged oil passage, the pressure in the oil groove heightens due to an increased flow rate, but the pressure elevation in the back pressure chamber is small, resulting in reduced friction loss at the thrust surface between the two scrolls. On the other hand, by increasing the oil passage area, the oil content in the refrigerant flow increases. Considering all these factors, the energy efficiency ratio could be improved by about 3.6% under the ARI condition by an optimal oil groove design.

Aesthetic Correction of a Protrusive Forehead through Repositioning of the Anterior Wall of the Frontal Sinus

  • Han, Daniel Seungyoul;Park, Jin Hyung
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.3
    • /
    • pp.129-132
    • /
    • 2014
  • Facial skeletal remodeling was revolutionized more than 30 years ago, by the work of Tessier and other craniofacial surgeons. However, the need to correct the skeleton in the upper third of the face is not frequently diagnosed or treated in aesthetic facial surgery. Here, we report on the aesthetic correction of a protrusive forehead. A patient visited our hospital for aesthetic contouring with a prominent forehead. The anterior wall of the frontal sinus was removed with a craniotome via the bicoronal approach. After the excised bone was repositioned, it was fixed with a titanium mesh plate and screws. An electric burr was used to contour the supraorbital rim and frontal bone. Once the desired shape was achieved, the periosteum was replaced, and the wound was closed in layers. When performed properly, frontal sinus contouring could significantly improve the appearance in patients with a prominent forehead. Plastic surgeons must carefully evaluate patients with a prominent forehead for skeletal remodeling that involves the accurate and safe repositioning of the anterior wall of the frontal sinus.

An Experimental Study on Electrohydrodynamic Atomization of Non-Conducting Liquid (비전도성 액체의 전기수력학적 분무에 관한 실험적 연구)

  • Lee, Ki-Joon;Park, Jong-Seung;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1322-1327
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with increase of liquid flow rate and input voltage. When the distance between the needle and the ground electrode becomes closer, total, leakage and spray current increase, but the onset voltage for dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the flow rate because the higher charge density is achieved with the larger liquid velocity in addition to the enhanced aerodynamic effect.

  • PDF

Analysis of Steady and Unsteady Performance for 3-D Surface Effect Wing (3차원 표면효과익의 정상 및 비정상 성능해석)

  • Il-Ryong Park;Ho-Hwan Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.3
    • /
    • pp.14-25
    • /
    • 1998
  • This paper describes the numerical modelling for the steady and unsteady forces of 3-D wings flying near the free surface based on a potential based panel method. For the steady problem where a wing flies over the fixed float surface, steady lift and drag forces are calculated for wings with and without end-plates having different sections, angle of attacks, aspect patios and flying heights. These numerical results are compared with the wind tunnel test results. The unsteady problem is treated as a boundary value one where a wing flies over the described wavy surface. The unsteady lift force variations of a wing due to different wave lengths and heights are calculated at different flying heights.

  • PDF

Column design of cold-formed stainless steel slender circular hollow sections

  • Young, Ben;Ellobody, Ehab
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.285-302
    • /
    • 2006
  • This paper describes the design and behaviour of cold-formed stainless steel slender circular hollow section columns. The columns were compressed between fixed ends at different column lengths. The investigation focused on large diameter-to-plate thickness (D/t) ratio ranged from 100 to 200. An accurate finite element model has been developed. The initial local and overall geometric imperfections have been included in the finite element model. The material nonlinearity of the cold-formed stainless steel sections was incorporated in the model. The column strengths, load-shortening curves as well as failure modes were predicted using the finite element model. The nonlinear finite element model was verified against test results. An extensive parametric study was carried out to study the effects of cross-section geometries on the strength and behaviour of stainless steel slender circular hollow section columns with large D/t ratio. The column strengths predicted from the parametric study were compared with the design strengths calculated using the American Specification, Australian/New Zealand Standard and European Code for cold-formed stainless steel structures. It is shown that the design strengths obtained using the Australian/New Zealand and European specifications are generally unconservative for the cold-formed stainless steel slender circular hollow section columns, while the American Specification is generally quite conservative. Therefore, design equation was proposed in this study.

Effect of Inlet Geometries on the Two-Phase Flow Distribution at Header-Channel Junction (헤더-채널 분기관에서의 헤더 입구 형상이 2상 유동 분배에 미치는 영향에 대한 실험적 연구)

  • Lee, Jun Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.324-330
    • /
    • 2013
  • The main objective of this work is to experimentally investigate the effect of inlet geometries on the distribution of two-phase annular flow at header-channel junctions simulating the corresponding parts of compact heat exchangers. The cross-section of the header and the channels were fixed to $16mm{\times}16mm$ and $12mm{\times}1.8mm$, respectively. Experiments were performed for the mass flux and the mass quality ranges of $30{\sim}140kg/m^2s$ and 0.3~0.7, respectively. Air and water were used as the test fluids. Three different inlet geometries of the header were tested:no restriction (case A), a single 8 mm hole at the center (case B), and nine 2 mm holes around the center (case C) at the inlet, respectively. The tendencies of the two-phase flow distribution were different, in each case. For cases B and C (flow resistance exists), more uniform flow distribution results were seen, compared with case A(no flow resistance), due to the flow pattern change to mist flow from annular flow at the inlet, and the flow recirculation near the end plate of the header.

A Study on the Relationship between Oxygen and Carrier Concentration in a GZO Film on an Amorphous Structure (GZO 박막에 대한 비정질 구조에 따른 산소공공과 전하농도의 연관성에 대한 연구)

  • Kim, Do Hyoung;Kim, Hong Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.25-29
    • /
    • 2015
  • In this study, RF magnetron sputtering was used to investigate the relationship between oxygen vacancy and carrier concentration in a GZO film on an amorphous structure. RF power was fixed at 50W and Ar flow was changed on a glass plate to create a thin film at room temperature. The transmittance of Al-adopted amorphous GZO was measured at 85% or higher; therefore, the transmittance was shown to be outstanding in all films. The hall mobility was also shown to be higher at the film showing the high transmittance at a short-wavelength, whereas the optical energy gap was shown to be higher at the film with high oxygen vacancy. The oxygen vacancy at the amorphous oxide semi-conductor increased the optical energy gap while it was not directly involved in increasing the mobility. The oxygen vacancy increases the carrier concentration while lowering the quality of amorphous structure; such factor, therefore affected the mobility. The increase of amorphous property is a direct way to increase the mobility of amorphous oxide semi-conductor.