• 제목/요약/키워드: fire-resistant construction

검색결과 94건 처리시간 0.02초

재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구 (A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test)

  • 김우재;김현배;김규용;김영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

화재피해를 입은 철근콘크리트 단주시험체의 보수재료 적용 후 내화성능 평가 (Fire Resistant Performance after Application of Repaired Materials for Fire-Damaged Reinforced Concrete Column)

  • 심상락;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.147-154
    • /
    • 2020
  • Currently, there are no specific repair methods for RC structures damaged by fire, and repair methods are applied when durability deteriorates due to aging. In addition, a number of recent studies have been reported that have conducted fire resistance assessment of the repair materials themselves, assuming exposure to high-temperature environments such as fires. However, researches that evaluate the fire resistance performance of the repair materials by applying existing repair materials to the actual fire damaged reinforced concrete structures are very rare. Therefore, in this study, a number of existing repair materials were applied to fire-damaged concrete column to compare and evaluate the fire resistance performance with the original cover concrete.

슬림 AU 합성보의 내화해석 (Fire Performance Analysis of SLIM AU Composite Beam)

  • 김명한;오명호;민정기
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.133-140
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.

초고층 구조물을 위한 특수 콘크리트 (Advanced concrete for Skyscraper)

  • 조윤구
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.106-111
    • /
    • 2008
  • 본 논문에서는 전 세계적인 추세인 초고층 구조물의 건설에 필수적인 특수 콘크리트에 대하여 알아 보고자한다. 초고층 구조물에 사용되는 특수 콘크리트를 크게 초고강도 콘크리트, 저발열 콘크리트, 내화 콘크리트 그리고 방폭 콘크리트로 나누고 각각의 필요성, 원리, 적용사례 등을 기술하였다. 본문 뒷부분에서는 현대건설에서 개발하고 있는 특수 콘크리트 기술에 대하여 정리하고 특수 콘크리트의 향후 방향에 대하여 언급하였다.

  • PDF

설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석 (Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement)

  • 김성덕;김상연;배기선;박수희;이범식
    • 한국건축시공학회지
    • /
    • 제10권5호
    • /
    • pp.113-119
    • /
    • 2010
  • 설계강도 80 MPa인 고강도 콘크리트가 B/P에서 대량 생산, 공급되는 현장조건하에서도 시험실 조건과 동일한 재료물성을 발휘하는지 여부를 평가하기 위하여 내화시험과 시험시공을 수행하고, 그 결과를 평가하였다. 내화성능평가 결과, 복합섬유(PP섬유, NY섬유)를 0.075 %혼입한 80 MPa의 고강도 콘크리트가 내화성능과 폭렬방지 성능이 우수한 것으로 나타났다. 고강도 콘크리트 시험시공 결과, 압송 전에는 공기량, 유동성, 압축강도 등을 모두 만족하였으나, 압송 후에는 슬럼프 플로가 목표물성보다 다소 작게 평가되어 개선이 필요한 것으로 판단되었다. 고강도 콘크리트의 수화온도 역시 관련 기준을 만족하였다. 고강도 콘크리트의 단위시간당 타설량은 약 $44m^3$로 우수한 것으로 나타났으며, 충전성 또한 매우 우수한 것으로 평가되었다. 개발된 3성분계 고강도 콘크리트는 실리카 흄이 사용된 기존 고강도콘크리트와 비교하여 경제적이며 경화 전 후의 재료물성과 시공성이 우수하여 초고층 구조물의 건립 시 유용하게 활용될 수 있을 것으로 판단된다.

스틸하우스 설계 자동화의 필요성과 적용방법에 관한 연구 (Study on the Design Automation of Steel House Shop drawing)

  • 원완연;박현수
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.103-106
    • /
    • 2006
  • This study proposes a method of generating steel house shop drawing in an automated design method, reducing construction manpower and period. With one hour fire-resistant approval code, reflecting work ability and efficiency, steel-framed house market is expected to extend from one or two story house to multi-purpose facilities up to four story height. More models have been constructed in this system than the first appearance of fire-resistant approval in Korea in 1997. Also, cost estimation of components such as frame walls, roof trusses and floors is obtained with shop drawings. Also, the lack of suppliers of steel framed house shop drawing and unstandardized drawing method get constructors have difficulty in understanding its design. In steel framed house industry, shop drawings are essential part in building and constructing framework and they have major effects on construction deadlines and expenses. By exploring method of shop drawing automation, this study aims to optimize work flow with a standardized drawing method. The proposed system can be applied to manufacturing automation in domestic industry of factory-built panelizing method in the near future.

  • PDF

실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구 (A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture)

  • 조성오;김용성
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구 (Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall)

  • 황지순;김우재;김대회;박동철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.205-206
    • /
    • 2011
  • 이노가닉 폴리머 콘크리트는 비소성 알카리 활성화 콘크리트의 일종으로 여러 가지 우수한 성능을 가지고 있으며, 그 중에서도 고온에서의 열적특성이 우수한 것으로 알려져 있다. 이에 따라, 이노가닉 폴리머 콘크리트를 이용한 경량패널을 제조하여, 소형가열로 내화시험을 측정한 결과 3시간 가열후 이면상승온도가 평균 82℃ 이하로 확인되어 공동주택의 내화벽체로 활용이 가능할 것으로 판단된다.

  • PDF

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

The fire-risks of cost-optimized steel structures: Fire-resistant and hot-rolled carbon steel

  • Garcia, Harkaitz;Cuadrado, Jesus;Biezma, Maria V.;Calderon, Inigo
    • Structural Engineering and Mechanics
    • /
    • 제78권1호
    • /
    • pp.67-75
    • /
    • 2021
  • This work studies the behaviour of a steel portal frame selection under fire exposure, considering both span lengths and fire exposure times as variables. Such structures combine carbon steel (S275), fireproof micro-alloyed steel (FR), and coatings of intumescent paint with variable thicknesses, improving thereby the flame retardant behaviour of the steel structure. Thus, the main contribution of this study is the optimization of the portal frames by combining both steels, analysing the resulting costs influence on the final dimensions. Besides, the topological optimization of each steel component within the structure is also defined, in accordance with the following variables: weather conditions, span, paint thickness, and cost of steel. The results mainly confirmed that using both FR and S275 grades with intumescent painting is the Pareto optimum when considering performance, feasibility and costs of such portal frames widely used for industrial facilities.