Importance-Performance Analysis for Developing Convergence Firefighter Helmets (융합 소방용 안전모 개발을 위한 중요도-만족도 연관 분석)

  • Oh, Mi-Ok;Shin, Jong-Kuk;Kang, Myung Chang;Shin, Bo-Sung;Moon, Min-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • This study executes Importance-Performance Analysis (IPA) on existing firefighter helmet attributes and gathers ideas for improvements from fire-fighting officers to develop a convergence firefighter helmet. The results of empirical analysis were as follows: First, the weight, head fitness, ease of wearing and removal, and ease of managing the existing helmet's attributes need urgent improvement. In addition, fire-fighting officers want to add innovative functions such as oxygen deficiency alarms, poison gas sensors, temperature sensors, and network communication systems to the convergence firefighter helmet under development.

A Numerical Study on the Effect of Coefficient of Restitution to Heat Transfer in a Conical Fluidized Bed Combustor (원추형 유동층 연소기 내의 열전달에 미치는 복원계수의 영향에 대한 수치해석 연구)

  • Kang, Seung Mo;Park, Woe-Chul;Abdelmotalib, Hamada;Ko, Dong Kuk;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.38-44
    • /
    • 2015
  • In this paper, numerical simulations on conical fluidized bed combustors were carried out to estimate the effect of coefficients of restitution between particle and particle and particle to wall on hydrodynamics and heat transfer. The Eulerian-Eulerian two-fluid model was used to simulate the hydrodynamics and heat transfer in a conical fluidized bed combustor. The solid phase properties were calculated by applying the kinetic theory of granular flow. Simulations results show that increasing the restitution coefficient between the particle and particle results in increasing the bed pressure drop. On other hand, the increasing of particle to wall coefficient of restitution results in decreasing the bed pressure drop. It is found that the coefficient of restitution has little effect on heat transfer.

Infrastructure of Propulsion Test Facility of Liquid Rocket (액체로켓 추진기관 시험설비 기반시설 고찰)

  • Cho, Namkyung;Kim, Sunghyuk;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2019
  • Liquid rocket propulsion test facility should provide for the interface condition installed on the upper level system for the test article. In addition, safety provision should be provided to be ready for accident such as explosion which can be occurred during development stage. For this purpose infra-structures of test facilities must be constructed so that stable combustion test can be performed and be guard against accidents. In this article, various aspects for infrastructures of propulsion test facilities are investigated including architecture and civil engineering aspects, test stand, room arrangements, interfaces among facilities, fire-fighting facilities, electrical power facilities.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

A Study on the Consciousness Survey of Improvement of Emergency Rescue Training -Based on the Fire Fighting Organizations in Gangwon Province- (긴급구조훈련 개선에 관한 의식조사 연구 -강원도 소방조직을 중심으로-)

  • Choi, Yunjung;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.440-449
    • /
    • 2019
  • Purpose: Fire-fighting organizations are the very first agencies that take actions at a disaster scene, and emergency rescue training is carried out for prompt and systematic response. However, there is a need for a change due to the limitations in emergency rescue trainings such as perfunctory trainings or trainings without considering regional or environmental characteristics. Method: This study is to conduct theoretical review with regard to emergency rescue training and present a measure to improve the emergency rescue training through attitude survey targeting fire-fighting organizations in Gangwon area. Result: Facilities that cause difficulties when doing emergency rescue activity were mostly hazardous material storage and processing facilities. In terms of the level of emergency rescue and response task, most respondents answered that the emergency rescue was insufficient. The respondents answered that the effectiveness of emergency rescue training was helpful, but some responses showed that the training was not helpful because of scenario-based training, seeming training, similar training carried out every year, unrealistic training, and lack of competent authorities' interest and perfunctory participations. Most respondents answered for the appropriateness of emergency rescue training and evaluation that they were satisfied, however, they were not satisfied with the evaluation methods irrelevant to the type of training, evaluation methods requiring unnecessary training scale, and evaluation methods leading perfunctory participations of competent authorities. Lastly, respondents mostly answered that training reflecting various damage situations are necessary regarding the demand on the improvement of emergency rescue training. Conclusion: The improvement measures for emergency rescue training are as follows. First, it is necessary to set and prepare various training contents in accordance with regional characteristics by reviewing major disasters occurred in the region. Second, it is necessary to revise the emergency rescue training guidelines and manuals for appropriate training plan for each fire station, provide education and training for working-level staff members, and establish training in a way that types, tactics, and strategies of emergency rescue training could be utilized practically. Third, it is necessary to prepare a scheme that can lead participation and provide incentive or penalty from the planning stage of training in order to increase the participation of supporting and competent authorities when an actual disaster occurs. Fourth, it is necessary to establish support arrangements and cooperative systems by authority through training by fire stations or zones in preparation for disaster situations that may occur simultaneously. Fifth, it is necessary to put emphasis on the training process rather than the result for emergency rescue training and evaluation, pay attention to the identification of supplement points for each disaster situation and make improvements. Especially, type or form of training should be considered rather than evaluating the execution status of detailed processes, and the evaluation measure that can consider the completeness (proficiency) of training and the status of role performance rather than the scale of training should be prepared. Sixth, type and method of training should be improved in accordance with the characteristics of each fire station by identifying the demand of working-level staff members for an efficient emergency rescue training.

Influence Factors on Job Satisfaction Factor and Spatial Environments Evaluation of Fire-Fighting Officer - Focused on Fire Officials in Incheon Metropolitan City - (소방공무원의 직무만족요소에 의한 공간만족평가 영향에 관한 연구 - 인천지방 소방공무원을 중심으로 -)

  • Han, Myoung-Heum
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • A study on how fire officer's job satisfaction factors influence space satisfaction rates. This article will conduct regression analysis for the study on these three problems. 'What are the factors of fire officer's job satisfaction?', 'Does space satisfaction rates influence job satisfaction rates?', 'Which job satisfaction factor influence space satisfaction rate?' Therefore, variables were set based on the prior study, and before regression analysis was conducted, variables were purified through analysis on primary factor and reliability analysis, and hypothesis test was done via variable calculation. According to the prior study, factors that influence job satisfaction rates are as following; self-regulation of tasks, ethics and responsibility level, relationship with colleagues, job identity. And regression analysis showed that space satisfaction rates do not influence job satisfaction rates. The writer thinks that it's showing that Korean fire officers tend to prioritize colleague relationship and job identity over space improvements. And the factor that influence job satisfaction rates turned out to be the self-regulation of tasks, and the writer estimates that it's reflecting the hierarchical organization culture of current Korean fire officers. Therefore, future Korean fire station design plans need to consider a space plan that provides fire officer's private self-regulation of tasks.

A Study on Communication Network Construction of Portable Fire Prevention System (이동형 화재 방재시스템의 통신네트워크 구축에 관한 연구)

  • Kwak, D.K.;Choi, S.H.;Baek, W.J.;Lee, C.S.;Ghil, M.S.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.34-35
    • /
    • 2016
  • This study is to minimize the damage and fire early warning and research on mobile communications network of the emergency fire alarm system based on the IoT to the transmission in real time. The spread of such systems can be expected to businesses expand to technology that can replace or complement existing fire fighting system, it is also expected to a large ripple effect as an important technology that can minimize the damage to real-time detect the ignition point.

  • PDF

Development of Eire Extinguishment and Life-saving Technology for Indoor Environment (실내 화재 진압 및 인명구조 기술 개발)

  • Oh, Ju-Hwan;Choi, Jae-Seck;Lee, Woo-Jun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.108-113
    • /
    • 2007
  • The robot introduced in this paper is the Fire-Extinguishing Rescue Robot for indoor work which is considered to be a part of the Operation for Future Developmental Power. It is briefly introduced about the background of how we began this project, our goals, where we are today and what we would like to achieve from now on. Main contents include introduction to the equipments for Fire-Extinguishing Rescue robots that have been developed in advanced countries and the compositional concept of the developmental process, the GUI schematic, searching methods for fire inside a house, mechanical schematic and the present conditions of how the core technologies are developing through.

Analysis of Electrical Installation Survey at Conventional Markets (재래시장 전기설비 실태조사 분석)

  • Lee, Sang-Ick;Jeon, Hyun-Jae;Kim, Gi-Hyun;Bae, Seok-Myung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.186-191
    • /
    • 2008
  • The conventional markets is badly damaged by a big fire because of no proper fire fighting management system. The cause of electricity fire is the aging and contact badness of electric equipment. The supervisory detecting system is needed to develop because the electric equipment is located to non visible and non exposing place. In this paper, we investigated the receiving and distributing board, the panel board and the fire prevention system of 17 domestic conventional markets. As a result of survey, capacity of distributing boards is mainly 600A and materials of distributing boards are synthetic resins 49%, metal 44%. ELB is mainly used as branch circuit breaker.

An Empirical Study on the Sprinkler Operational Characteristics and Escape Time Estimation (스프링클러 작동특성(作動特性)과 피난평가(避難評價)에 관한 실증적(實證的) 연구(硏究))

  • Jin, Bok-Kweon
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.37-50
    • /
    • 2006
  • The trends in building construction these days are moving towards having better work spaces and greater suitability for the use of information technology. Therefore people can work in a more relaxed delightful and pleasant environment. Accident such as like fire could cause the mass destruction of human beings. This paper aims to evaluate the path of the spread of a fire and the suitability of fire fighting appliances for maximum egress time. General advanced phase of compartment. Aswell, we analyzed and verified the path of the flame in compartment fires. Also we conducted an analysis of the adaptation of sprinkler systems concerned with sprinkler RTI. Moreover those evaluation is made more earlier by the development and use of computer simulation program and rapid progress to apply PBFD (Performance Based Fire Design).