Evaluation of Sound Insulation Performance of Extruded Cement Panel with a-Hemihydrate Gypsum

  • Kim, Jin-Man;Choi, Duck-Jin
    • 한국건축시공학회지
    • /
    • 제12권6호
    • /
    • pp.575-585
    • /
    • 2012
  • The extruded cement panel, which has many advantages as a prefabricated method, has been limited in its application due to its low fire-resistance. However, an extruded cement panel produced by mixing a-hemihydrate gypsum offers dramatically improved fire-resistance and is expected to have wide-ranging applications in the construction sector as an interior material or partition wall between housing units. Sound insulation performance is very important for the partition wall between housing units. In this study, the sound insulation performance of the extruded cement panel produced through the mixture of a-hemihydrate gypsum is reviewed in order to determine its usability for a partition wall between housing units and for interior materials. Through the review it was found that the wall formed using the extruded cement panels produced by mixing the a-hemihydrate gypsum have ★★★ class in sound insulation test, equal or superior compared with the other two types of extruded cement panel walls currently available in the market.

현무암섬유 기반 건축용 막재의 강도 비교 연구 (A Comparative Study of Tensile Strength of Architectural Membrane using Basalt Fiber)

  • 김지현;신현욱;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2016
  • The membrane structure is being applied in structures for various uses for its many advantages as permeableness, lightweightness, constructability, resource saving, and management cost reduction, and the usage is being expanded. However, despite the development of membrane structure, the standard for architectural membrane performance that considered fire safety is still inadequate. Therefore, this study applied basalt fiber with flame resistance on architectural membrane. Also, this study confirmed the membrane applicability of basalt fiber through comparison with existing architectural membrane.

  • PDF

Simplified P-M interaction curve model for reinforced concrete columns exposed to standard fire

  • Lee, Deuck Hang;Cheon, Na-Rae;Kim, Minsu;Lee, Jungmin;Oh, Jae-Yuel;Kim, Kang Su
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.545-553
    • /
    • 2017
  • In the authors' previous study, an axial force-flexural moment (P-M) interaction curve model was proposed to evaluate fire-resisting performances of reinforced concrete (RC) column members. The proposed method appeared to properly consider the axial and flexural strength degradations including the secondary moment effects in RC columns due to fire damage. However, the detailed P-M interaction curve model proposed in the authors' previous study requires somewhat complex computational procedures and iterative calculations, which makes it difficult to be used for practical design in its current form. Thus, the aim of this study was to develop a simplified P-M interaction curve model of RC columns exposed to fire considering the effects of fire damage on the material performances and magnitudes of secondary moments. The simplified P-M interaction model proposed in this study was verified using 66 column fire test results collected from literature, and the verification results showed that the proposed simplified method can provide an adequate analysis accuracy of the failure loads and fire-resisting times of the RC column specimens.

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • 제32권6호
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

구조용 경량골재 콘크리트의 폭렬특성 (Explosive Spalling of Structural Lightweight Aggregate Concrete)

  • 송훈;이종찬;이세현;김우재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.477-480
    • /
    • 2006
  • Normally, with all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Especially, high strength concrete and lightweight aggregate concrete is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with explosive spalling of lightweight concrete using structural lightweight aggregate. From the experimental test result, lightweight aggregate concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

수소 제트화염이 터널 구조체에 미치는 영향 분석 (Analysis of effect of hydrogen jet fire on tunnel structure)

  • 박진욱;유용호;김휘성
    • 한국터널지하공간학회 논문집
    • /
    • 제23권6호
    • /
    • pp.535-547
    • /
    • 2021
  • 국내에서는 수소경제 활성화 정책을 수립하고 수소사회 실현을 위해 수소 인프라 및 수소차 보급 확대를 계획 하고 있다. 이에 따라 수소차의 보급이 급속도로 이루어질 것으로 예상되며, 동시에 수소차의 사고에 대응하기 위한 대책의 확립이 요구되고 있다. 본 연구에서는 수소차에 의해서 발생되는 수소 제트화염이 터널 내부 벽체에 미치는 영향과 내부 복사열 특성 분석을 위해 실험적 연구를 수행하였다. 실험은 수소차에서 발생되는 조건과 동일하게 하기 위해 분사압력을 700 bar로 설정하고, 분사노즐 직경은 1.8 mm로 설정하였다. 또한, 일반 터널에 적용되고 있는 콘크리트 압축강도 40 MPa의 터널 내화 시험체를 제작하고 제트화염 분사노즐과 시험체간의 이격거리에 따른 영향을 검토하였다. 분사노즐과 터널 내화시험체의 이격거리를 변수로 하여 2 m와 4 m에 대해 결과를 분석하였다. 그 결과로부터 시험체 내부 최대 온도는 1,349.9℃ (이격거리 2 m)가 측정되었고, 제트화염 주위 복사열은 최대 39.16 kW/m2까지 나타났다.

폐콘크리트 순환자원을 이용한 건설재료의 화재내력 및 단열성에 관한 실험적 연구 (Experimental Study on Fire Resistant Capacity and Thermal Conduction of Construction Material Using the Circulation Resources)

  • 최재남;홍세화;손기상
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.121-128
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.

단판(單板)의 약제처리(藥劑處理)가 합판성질개선(合板性質改善)에 미치는 영향(影響) (The Effect of Pretreatment of Veneer on the Improvement of Plywood Quality)

  • 심종섭
    • Journal of the Korean Wood Science and Technology
    • /
    • 제10권3호
    • /
    • pp.152-164
    • /
    • 1982
  • 1. In order to make the improvement of plywood quality, this study has been made. The pretreatments applied to the veneers are as follows. a) The soaking treatment of the veneer in 30 percent methanol solution for 24 hours was applied to remove some resinous materials which may cause many stain discolouring on the face of finished plywood. b) The preservative treatment of the veneer in 2 percent malenit solution for 2 to 3 minutes was adopted to make resistance against decay and insect damages. c) The fire retardant treatment of the veneer in 40 percent ammonium phosphate solution for 2 hours was applied to give retardation effect against fire burning. 2. The results summarized in this study are as follows. a) One percent resinous materials was extracted, after the soaking of the veneers in 30 percent diluted methanol. b) No marks of the dirty stains of resinous materials on the face of the treated plywood was shown, although many quite dirty stains on the face of untreated plywood have contrary seen. c) However, the strip shear test strength of the treated plywood was not decreased. It means that there is no difference in the strength between the treated plywood and the untreated plywood. The strength values were 25.08 kg/$cm^2$ and 24.98 kg/$cm^2$, respectively. d) The strip shear test strength of plywood made of the treated veneers in 2 percent malenit solution was not decreased. e) The slight decrease of the strip shear test strength of the treated plywood made of the treated veneer in 40 percent ammonuim phosphate solution was shown. However, the remarkable difference of the fire retardation activities between the treated specimens and the untreated specimens has seen as in Table 10, that is, the fire proofed specimens had taken about 28 seconds to start to burn, while the untreated specimens had taken 15 seconds to reach to burning. This means that the fire retardation effect of the fire proofed plywood was greater than that of the unproofed plywood.

  • PDF