• 제목/요약/키워드: fire performance test

검색결과 616건 처리시간 0.027초

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구 (Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.82-88
    • /
    • 2010
  • 건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

스터드커넥터의 내화성능에 관한 연구 (Study on Fire Performance of Stud Connectors)

  • 김성배;한상훈;최승관
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.59-66
    • /
    • 2009
  • 본 연구는 합성구조에 사용되는 스터드커넥터의 화재시 성능에 대한 연구이다. 스터드커넥터는 전단연결재로 가장 폭넓게 사용되고 있으며, 콘크리트와 강재를 일체화시켜 합성 성능을 확보한다. 스터드커넥터에 대한 상세 내화성능은 아직 명확한 자료가 없으며, 향후 성능설계에서 무피복 합성보 등에 대한 설계 자료로 요구 된다. 본 실험의 스터드커넥터 성능시험은 푸시 아웃 실험을 변형하여 특수 전기로와 결합 ISO 표준온도곡선을 기본으로 거동 성능실험을 수행하였으며, 화재 조건의 파괴 형상을 기반으로 성능 분석 방법을 제안하였다.

축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio)

  • 황규재;조범연;여인환
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.26-31
    • /
    • 2013
  • 본 연구의 목적은 성능적 내화설계를 기반으로 한 철근콘크리트 기둥의 내화성능 평가를 최종 목표로 철근콘크리트 기둥의 열전달 해석을 통한 온도분포와 재하가열실험을 통한 수축량으로 적정 축력비를 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. 편심이 전혀 없는 순수축력을 기준으로 축력비 0.30, 0.35, 0.40, 0.47을 재하한 결과, 0.40 이상의 축력비를 확보하여야 내화성능을 만족할 수 있다고 판단하였다.

화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 비파괴 검사 (Non destructive test of Fire-damaged reinforced concreted beams with high strength concrete)

  • 신미경;신영수;이차돈;홍성걸;김희선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.651-654
    • /
    • 2003
  • Non-destructive testing is essential in the inspection of alteration, repair and new construction in construction industry. This paper is to evaluate the strength variation of fire damaged concrete by non-destructive testing. Furthermore, It is to infer the recovery degree of residual strength of fire-damaged concrete. For this purpose, researchers are exploring the performance of non-destructive testing method using ultrasonic testing and Schmidt hammer in concrete specimens. Testing is performed four-times: before fire test, directly after fire test, after 20 days and after 60 days.

  • PDF

건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구 (A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings)

  • 홍성호;최문수
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

표준화재 재하조건 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 전열 특성 및 화재 거동에 관한 연구 (A Study on Fire Performance and Heat Transfer of HPC Column with Fiber-Cocktail in ISO Fire under Loading Condition)

  • 김흥열;김형준;전현규;염광수
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.29-39
    • /
    • 2010
  • 이 연구에서는 고강도 콘크리트의 전열특성 및 화재거동을 구명하기 위해 실증실험과 수치해석을 병행하였으며, 화재실험조건 및 제약 상황으로 인해 실험을 통해 도출할 수 없는 고강도 콘크리트의 화재성상은 수치해석을 통해 예측하였다. 이를 위해 수치해석결과와 실험 결과를 비교 검증하여 해석기법의 신뢰성을 확보하였으며, 80 MPa 및 100 MPa의 고강도 콘크리트의 전열특성 및 화재거동을 상용 소프트웨어인 아바쿠스(V.6.8)를 사용하여 수치해석을 수행하였다. 실증실험결과 폭렬저감재를 혼입한 콘크리트의 경우 무 혼입 콘크리트에 비해 표준화재조건에서 약 25~55% 정도의 기둥 수축량이 제어되어 내화성능이 향상되었으며, 이는 섬유혼입으로 인해 콘크리트의 전열특성이 제어되어 기둥부재의 내화성능을 향상시키기 때문이다.

무내화피복 CFT 공법의 내화성능 확보를 위한 실험적 연구 (An Experimental Study on the Ensuring the Fire Resistance Performance of Non-Refractory Coating CFT)

  • 이지환;한민철
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.273-280
    • /
    • 2015
  • 본 연구는 3시간 내화성능을 만족할 수 있는 고성능 무내화피복 CFT 기둥 개발을 위한 연구로서, 고로슬래그 미분말 치환율에 따른 성능평가를 실시한 결과 고로슬래그 미분말 치환율이 증가함에 따라 내화성능이 개선되는 것을 확인 할 수 있었으며, 내화성능을 고려한 CFT 기둥용 100MPa 충전콘크리트의 고로슬래그 미분말 적정 사용량은 40%로 나타났다. 이에 따라 고로슬래그 미분말 40% 혼입 100MPa 충전콘크리트를 적용한 CFT 실물 시험체를 대상으로 재하하중별 내화시험을 실시한 결과 재하하중이 증가함에 따라 내화성능 발현시간이 감소하는 것으로 나타났으며, 재하하중 2,000kN에서는 240분 이상의 내화성능을 나타내었고, 3,000kN에서는 184분, 4,000kN에서는 120분의 내화성능을 나타내었다.

터널 내화용 시멘트계 재료의 개발 및 성능 평가 (Development and Performance of Cementitious Materials for Fire Resistance of Tunnel)

  • 원종필;최석원;박찬기;박해균
    • 대한토목학회논문집
    • /
    • 제26권4C호
    • /
    • pp.265-273
    • /
    • 2006
  • 본 연구의 터널 내화용 시멘트계 재료의 역학적 특성 및 내화성능을 평가하는 것이다. 이와 같은 목적을 달성하기 위하여 본 연구의 과정은 세단계로 나눌 수 있다. 첫 번째 과정은 서로 다른 종류의 재료를 이용하여 내화시험을 실시한 후 기본 배합비를 결정하는 것이다. 두 번째 과정으로 기본 배합비의 성능을 평가하기 위하여 내화특성 시험을 실시하였다. 세 번째 과정으로 내화용 시멘트계 재료의 성능을 목표성능 및 기존 상용제품과 비교하였다. 개발된 내화용 시멘트계 재료가 목표값을 만족하면 연구를 멈추었고, 만족하지 못한다면 첫 번째 과정으로 돌아가 반복 시험을 실시하였다. 연구결과 개발된 제품 및 상용제품 모두 화재에 의한 폭렬이 발생하지 않았다. 또한 개발된 내화용 시멘트계 재료는 밀도가 큰 골재를 사용하여 우수한 압축강도, 휨강도 및 부착강도를 보여주었으며, 충분한 화재에 대한 저항성을 확보할 수 있었다.

걸침길이에 따른 PC 슬래브의 화재성능에 관한 실험적 연구 (Experimental Study on the Fire Performance of PC Slab by the Bearing Length)

  • 박시영;강현구;이호욱;곽시영;박준규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.14-22
    • /
    • 2022
  • 본 연구에서는 물류창고시설의 개발 증가에 따른 화재사고 증가에 대응하여 실외 환경에서의 PC 슬래브의 화재성능 평가를 위한 실물대 화재실험을 실시하였다. 실외 화재실험에 앞서 고온에서 강연선의 인장 항복 강도를 시험하여 기계적 물성을 분석하였다. 또한, 이전 연구들을 참고하여 강연선의 열적 특성과 콘크리트의 기계적, 열적 특성을 조사하였다. 실외 화재실험은 걸침길이가 50mm, 150mm인 동일한 슬래브 2개의 구조성능 및 내화성능을 분석하기 위해 수행되었다. 걸침길이가 길어질수록 처짐은 감소하였고, 걸침길이에 대한 수평 변위 또한 감소하였다. 200분 가량 진행된 실험에서 슬래브의 탈락이 발생하지 않아 현행 기준이 적절함이 확인되었다. 콘크리트의 폭렬 현상이 발생하여 강연선 일부가 끊어졌으나, 구조성능은 지속되었기 때문에 부착식 공법을 이용한 PSC 슬래브의 실용성을 확인할 수 있었다. 이에 따라, 물류창고 PC 슬래브의 내화성능 판단을 위한 기초 자료로 활용될 수 있을 것으로 기대된다.