Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests

온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구

  • Received : 2010.09.13
  • Accepted : 2010.12.10
  • Published : 2010.12.31

Abstract

Major structural elements such as columns and beams are designed to withstand the vertical and horizontal loads. Futhermore, when the structural elements were engulfed with fire the structural stability should be stand without failure. The beams have been developed in aspects of structural stability but an evaluation of fire performance was not done. So the data of fire resistance performance of beams filled with concrete at web on H-section is not known. The purpose of this paper is to analyse the correlation between temperature analysis and fire test with the beams and to show the fire resistance performance with two methods.

건축 구조물의 주요 구조부는 중력하중의 전달과 수평하중을 견디도록 설계, 시공되어야 함을 물론이고, 화재의 고열환경에서 부수적으로 발생되는 온도에 의한 추가하중을 지지하도록 설계되어야 한다. 강구조 건축물에서의 보부재는 중력 및 횡력 방향의 하중에 더 강한 지지력을 확보하기 위하여 H형강 웨브부분에 콘크리트를 충전하는 타입의 개발 및 적용이 이루어져 왔으나, 내화성능의 평가는 거의 이루어지지 않은 상태이다. 따라서 본 논문에서는 H형강 보부재의 웨브에 일반강도의 콘크리트로 충전된 시험체를 대상으로 열전도 해석에 의한 내화성능과 재하가열시험을 통한 내화성능을 각각 제시하고 상관성을 비교분석하였다.

Keywords

References

  1. 권인규, "강구조 부재의 표면온도 산정 및 내화피복 두께에 관한 연구", 한국화재소방학회 논문지, Vol.24, No.4, pp.55-61(2010).
  2. 최성관, 김성배, "TSC 합성보의 화재시 거동 및 전열특성에 관한 실험적 연구", 대한건축학회논문집, Vol.24, No.1, pp.27-35(2008).
  3. Elisabet Sterner, Ulf Wickstrom, "TASEF-Temperature Analysis of Structures Exposed to Fire-user's Manual" (1990).
  4. V.H. Patrick and T. Heimo, "Description of Swedish System of Fire Performance Based Regulation and Temperature Analysis of Structural Sections"(2003).
  5. Ove pertterson, Sven-Erik Magnusson, Jorgen Thor, "Fire Engineering Design of Steel Structures"(1976).
  6. 한국표준협회. KSF 2257-6, 건축구조부재의 내화시험방법 - 보의 성능조건(2006).