• Title/Summary/Keyword: fire investigations

Search Result 78, Processing Time 0.024 seconds

Characteristics of the Car Fires Related to a Diesel Particulate Filters and an Analysis of the Process of Proving Fire Causes (미세먼지 저감 장치와 관련된 자동차화재의 특징 및 화재원인 입증절차의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.99-107
    • /
    • 2018
  • Diesel cars employ a diesel particulate filter (DPF) to reduce the discharge of fine dust. However, cases of fires caused by DPFs have been reported in diesel cars. In this study, I examined the regulation of exhaust gas and exhaust gas recirculation in diesel cars. Then, I analyzed cases of car fires caused by DPFs, their characteristics, car fire factors related to DPFs and preventive measures, and their consideration in investigations of the causes of fires. Finally, regarding car fire investigations, this study proposed a process of proving that fires are caused by DPFs.

A Study on Research Technique of the combustibles an Housing Facilities in Korea (국내 주거시설의 가연물 조사 기법에 관한 연구)

  • Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.289-293
    • /
    • 2008
  • In performance-based on fire safety design of buildings, design fires are assumed to be relatively coarse information on potential combustible objects described by its name, weight, size and main constituent materials. As early as 1970s, researchers from Japan has employed various methods of research regarding combustibles investigations. In result, researchers came up with one method that is being presently used. Therefore, our country basis in collection of data for combustibles yielded average measure, receipt rate of furniture usage and execution of combustible investigations to occupancy zone of university respondents. We have found out problem about excessive usage of multi-outlet extensions through research.

  • PDF

Derivation of Cause Variables necessary for Electrostatic Fire/Explosion Risk Assessment and Accident Investigation (정전기 화재·폭발 위험성평가 및 사고조사에 필요한 발생원인 변수 도출)

  • Junghwan Byeon;Hyeongon Park
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.9-21
    • /
    • 2024
  • Static-electricity-induced fires and explosions persistently occur every year, averaging approximately 80 and 20 cases annually according to fire statistics provided by the National Fire Agency and industrial accident statistics provided by the Ministry of Employment and Labor, respectively. Despite the relatively low probabilities of these accidents, their potential risks are high. Consequently, effective risk assessment methodologies and accident investigation strategies are essential for efficiently managing static-electricity hazards in fire- and explosion-prone areas. Accordingly, this study aimed to identify the causal variables essential for accident investigations, thereby facilitating risk assessments and the implementation of effective recurrence prevention measures to mitigate static-electricity hazards in fire-and explosion-prone regions. To this end, industrial accident statistics recorded over the past decade (2012 to 2021) by the Ministry of Employment and Labor were analyzed to identify major fire and explosion incidents and related industrial accidents wherein static electricity was identified as a potential ignition source. Subsequently, relevant investigation reports (63 cases) were thoroughly analyzed. Based on the results of this analysis, existing electrostatic fire and explosion risk assessment techniques were refined and augmented. Moreover, factors essential for investigating electrostatic fire and explosion disasters were delineated, and the primary causal variables necessary for effective risk assessments and scientific investigations were derived.

Study of an Efficient Method for Securing Evidence During the Fire Investigation (화재조사 시 증거물의 효율적인 확보 방안에 관한 연구)

  • Ye, Su-Jo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.43-47
    • /
    • 2016
  • The recent changes in the judicial system in South Korea, including the stronger trial-centrism and legal market opening, have made fire investigations seek more scientific evidence and structure. The collection of physical evidence is very important to prove the substantial truth of a fire at the court. Without the appropriate physical proof, the credibility of a fire investigation is lost as evidence in a court. Therefore, the fire investigation team needs to carefully handle the fire site and fire initiation evidence because evidence of a fire incident can be destroyed easily by chemical and physical damage. In addition, the fire investigation team also needs to carefully record the collections of any evidence including pictures and their analysis. This study proposed the needs of the procedure manual and guidelines that can provide a step-by-step process of fire investigations in South Korea. This study also helps fire investigation agencies to secure fire-scene evidence to distinctly investigate the facts of fire. The guidelines and manual can eventually improve the ways for the fire investigation processes in South Korea.

A Study on the Improvement of Fire Safety in high-rise Building Construction in Legal aspects (법규적 측면에서 고찰한 고층 건축물 공사현장 화재안전 확보방안)

  • Park, Chan-Seok;Jeong, Il-Kyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.21-32
    • /
    • 2015
  • High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fire building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore - (건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상-)

  • Nam, Dong-Gun;Yuji, Hasemi;Jung, Jong-Jin;Lim, Woo-Sub;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

An Identification of Sungnyemun Fire as a Case Study (숭례문 화재감식 사례 연구)

  • Choi, S.B.;Lee, S.J.;Lee, S.H.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.74-82
    • /
    • 2008
  • The fire of Sungnyemun, National Treasure of No.1, gave to the Korean people and fire investigators big pains. The aim of this study are the identification of combustion traces and fire patterns of wooden building fire, burned with an accelerator, after spraying flammable materials on the wooden floor through the field study observation. Also, in the case of the similar fire, these results will be as good references to fire investigators for accurate investigations.

  • PDF

A Study on the Egress distance of Semiconductor factory (반도체공장의 피난거리 연구)

  • Lee, Yong-Jae;Lee, Kung-Koo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.189-194
    • /
    • 2008
  • Augmentation of the high-technology industry semiconductor factories, to acquire productivity and competitive power, is an international tendency. This situation is demanding for the functional counteractions. This study is regarding egress distance pertaining to installation of direct stairs. First, analyze situations and danger characteristics of LCD Factories. Second, through investigations and analysis of both domestic and foreign Egress Distance Code, propose rational Egress Distance Code pertaining to installation of direct stairs.

  • PDF

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.