미세 물 분무 소화 성능에 관한 연구 (A study on the Water Mist Fire Suppression Performance)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

무인기관실에 효과적인 자동소화장치개발 관한 연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small craft)

  • 이찬재;강대선;김동석;곽지현
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.127-128
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, $8m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

선박용 미분무수 소화설비의 성능평가연구 (A Study on the performance test of Water mist system as a fire extinguish system for Ships)

  • 김성윤;안병호;김동석;김유택
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.155-156
    • /
    • 2006
  • Developed and conducted a performance test of the Water mist system that is satisfied with the requirement of a fire test requiring Class 3 Engine Mock-up exceeding net volume $3,000m^3$ as per IMO's MSC/Circ. 668 Appendix B(Test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of category A and cargo pump rooms).Even though fuel atomizing was continued for 15 sec. after stopping of the system according to the test method relating to the atomizing fire type, no fire was reignited. This result shows the excellence of the system. There was no damage to the contents of the system after the test.

  • PDF

산불피해지역 연료형태가 산불연소에 미치는 영향 (Influence on forest fire spread & intensity on fuel type of burnt area.)

  • 이시영;이명욱;염찬호;권춘근;박흥석;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.321-324
    • /
    • 2008
  • Forest fire danger rate of thinning area was lower than that of non thinning area, because height rate of leewardside in burned stem of tree, damage rate of crown and mortality of tree in thinning area were 30.8%, 37% and 48.4% lower than that in non-thinning area, respectively. Intensity of forest fire varied depending upon topographical condition up slope, down slope, aspect, location as well as species, breast height diameter and forest tree density. Especially, a mountaintop area was burned down when forest fire was spread to up slope ridge of mountain.

  • PDF

미세물분무 소화성능에 관한 연구 (A Study on the Performance of Water Mist Spray Fire Protection System)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

산불확산 시뮬레이션 도입을 위한 FARSITE 고찰 (Research on FARSITE for introducing a Forest fire simulator)

  • 이시영;박흥석
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.161-164
    • /
    • 2008
  • We studied a basic concept and application about FARSITE, which is a forest fire spread simulator for preventing and predicting fire in United States Department of Agriculture(USDA). And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. For this transition, we compared the behavior of the 2005 Yangyang forest fire with the result of a simulation. The spread direction is similar to real data. But, while mean spread of rate was 0.65km/hr on real data, it was 0.3km/hr on simulation. As Damaged area is 1,387ha on real, it was 5,368ha on simulation. Therefore, it is necessary to establish a fuel concept for more accurate simulation.

  • PDF

천연가스 및 수소연료를 사용하는 소형 고속 가스엔진에 있어서 성능 및 배기 특성 (An Experimental Study on Performance and the Exhaust Emissions in a Small High Speed Gas Engine by Using Natural Gas and Hydrogen Fuel)

  • 김복석;염노창광;추병길
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.20-26
    • /
    • 2000
  • 본 실험 연구에서는 소형 고속기관의 가스엔진 특성을 다양한 방법으로 수행하였다. 그리고, 가스연료인 천연가스, 수소연료 및 휘발유 연료를 사용한 기관의 성능을 분석하고, 그에 대한 배기특성과 연소과정에 대하여 고찰하였다. 수소기관의 높은 회전과 고부하로 운전할 때 발생하는 역화를 방지하기 위하여 가스연료기관에 교축밸브를 설치하여 공기량을 조절하였다. 그리고 수소연료에 질소를 혼합하여 실험을 수행하였다. 그 결과 소형고속기관에 가스연료를 적용하여 운전하였을 때 여러 특성을 파악할 수 있었다.

  • PDF

산림화재 종합위험등급화에 관한 연구 (A Study on the Wildland Fire Total Hazard Classification)

  • 김동현;김태구;김광일
    • 한국화재소방학회논문지
    • /
    • 제15권3호
    • /
    • pp.49-54
    • /
    • 2001
  • 최근 전 세계적으로 개발을 위한 고의적인 방화와 기상이변에 의한 산림화재의 급증과 피해규모가 증가하는 경향을 보이고 있다. 이와 같은 대형 산림화재는 국내에서도 같은 경향으로 나타나고 있다. 산림화재에 가장 효과적인 대응 방법은 화재발생 후의 진압보다는 화재예방 활동이라고 볼 수 있으며, 우선적으로 시급한 연구과제는 산림화재 예방 시스템에 관한 연구라 할 수 있다. 본 연구에서는 산림화재의 종합적 위험등급 개발을 위해 산림화재에 영향을 미치는 인자들에 대해 실험 및 자료들을 분석·고찰하여 6개 인자에 대한 개별적 위험성을 나타내었으며 각 인자들의 위험성 기여도에 따른 가중치를 적용하여 종합위험 등급을 설정하였다.

  • PDF

가스화재사고 원인조사 연구(LP가스를 중심으로) (Gas Fire Accident Cause Survey Study)

  • 김영철;차종호
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 가스연료는 사업체, 가정 등에서 사용이 증가하고 있으며, 이로 인한 사고위험도도 증가추세 이며, 사고원인 또한 다양하게 나타나고 있다. 가스사고를 원인(취급부주의, 제품불량 등), 형태(화재, 폭발, 누출 등), 피해등급(1,2,3,4급), 사상자(사망, 중상, 경상)로 분류하여 설명하였다. 가스연료 중 가정에서 많이 사용되는 LP가스 시설은 가스용기, 압력조정기, 호스, 중간밸브, 연소기로 크게 구분할 수 있으며, 이 구성요소 중의 어떤 부분에서 취급부주의, 제품불량 등의 원인에 의해 화재 및 폭발 등이 발생할 수 있다. 따라서 사고 발생시 과거화재사례에 대한 연구 및 화재조사 시 착안사항을 참고하여 정확한 원인이 규명되어야 한다.