• Title/Summary/Keyword: fire environment

Search Result 1,064, Processing Time 0.033 seconds

Study on Developing a Monitoring System for Safe Fire Testing (안전한 탄 발사시험을 위한 모니터링 시스템 개발에 관한 연구)

  • Ki Jae Sug
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.2
    • /
    • pp.65-72
    • /
    • 2005
  • On this research, we show some concrete examples as software design, 2D/3D display, graph display, and gage display to develop a data monitoring system for real time safe fire testing. Developed software which is simulation software for live fire testing, has been designed to display informations about whole test status in a live fire testing, and with this, user can control a live fire testing under the safe environment. Beside, we increase a security by using a authority of user to access on this software. and we develop it based on module designed to apply a requirement of user later on.

A Study on the Fire Safety of Residential Facility Considering Grenpel Tower Fire (그렌펠 타워 화재를 고려한 주거시설 화재안전에 관한 연구)

  • Lee, Kyu-Min;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • Recently, The Building has became high rising and large scaling according to development of economy in domestic and other country, also the building has increased a variety of functions of insulation for warmth. and it has a symbol of economic growth, but it has risk factor for disasters such as fire. this hazards include not only general building but also residential building. Recently, Grenfell Fire that occurred in England has increased in combustion to the 24th floor of the 1st floor for 1 hour. it resulted in 80 deaths and 79 missing persons. In this study we suggest basic data of residential building for fire safety design related to domestic environment to analyze the problem of Grenfell Tower.

  • PDF

Forest fire experiment toward the detection of forest fires using RS - Thermal and reflectance environment change observation at ground level -

  • Tanpipat, Veerachai;Honda, Kiyoshi
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.690-695
    • /
    • 2002
  • In this forest fire experiment the ThermoViewer was set up on the platform built on a tree and observed the temperature change, before, during and after the fire. The fire experiment had been carried out not only the day of the forest fire experiment but also continued for four months after the forest fire had been gone. The results from the experiment showed that the temperature difference is significant in the afternoon; therefore, afternoon satellite passing is better and suitable time for active forest fires and burnt scars detection; moreover, after 83 days, the burnt and un-burnt vegetation become almost the same condition, fully regenerated and the temperature difference become nearly 0$^{\circ}$ Celsius, so there is not enough temperature different between burnt and un-burnt vegetation for current sensors to distinguish the difference anymore.

  • PDF

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space (밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구)

  • Jeon, Kil Song;Hwang, Ji Hyun;Lee, Tea Won
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.

Study on Air Quality in the Case of Chemical Fires Using Proton Transfer Reaction-Time of Flight Mass Spectrometer (양자전이 비행시간 질량분석기를 이용한 화학물질 화재 발생 시 대기질 조사 연구)

  • Kim, So-Young;Cho, Dong-Ho;Park, Jungmin
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.84-90
    • /
    • 2018
  • Chemical accidents occur in various forms, such as explosions, leaks, spills, and fires. In particular, chemical accidents caused by fires seriously affect the surrounding air environment due to soot, causing anxiety to the residents. Therefore, it is important to identify the causative substances quickly and examine the influence of air quality in the surrounding area. In this paper, proton transfer reaction-time of flight mass spectrometry(PTR-ToFMS) was used to identify the causative material in a fire and monitor the air quality in real time. This analyzer is capable of real-time analysis with a rapid response time without sample collection and pretreatment. In addition, it is suitable for quantitative and qualitative analysis of most volatile organic compounds with high hydrogen affinity, to identify the cause of fire and examine the influence of ambient air. In April 2018, when a local fire occurred, methanol, acetone, and methyl ethyl ketone were the main causative agents in PTR-ToFMS.

Study on Fire Service Development of Fire Organization (소방조직의 업무영역개발에 관한 연구)

  • Kong, Ha-Sung;Lee, Woo-Seoung
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.172-180
    • /
    • 2008
  • Recently, diversification of social environment forces a fire administration new works. It is the development of Blue Ocean that a vision and substantive object the fire authority should pursuit. Now I recommend a variety of alternatives from the analysis of a survey of students who major in the fire or related fields, through the example of 120 service call program and police unit to discover new works. We should reclaim the name of department and promote life-contractive business with utilizing infra in the organization to get an remarkable success and reclaim Blue Ocean.

Development of Autonomous Surface Robot for Marine Fire Safety (해양 소방 안전을 위한 자율수상로봇 개발)

  • Jeong, Jinseok;Sa, Youngmin;Kim, Hyun-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.138-142
    • /
    • 2018
  • The marine industry is rapidly developing as a result of the increase in various needs in the marine environment. In addition, accidents involving ship fires and explosions and the resulting casualties are increasing. Generally, manpower and safety problems exist in fire fighting. A fire fighter in the form of an autonomous surface robot would be ideal for marine fire safety, because it has no manpower and safety problems. Therefore, an autonomous surface robot with the abilities of fire recognition and tracking, nozzle selection, position and attitude control, and fire fighting was developed and is discussed in this paper. The test and evaluation results of this robot showed the possibility of real-size applications and the need for additional studies.

Influence Factors on Job Satisfaction Factor and Spatial Environments Evaluation of Fire-Fighting Officer - Focused on Fire Officials in Incheon Metropolitan City - (소방공무원의 직무만족요소에 의한 공간만족평가 영향에 관한 연구 - 인천지방 소방공무원을 중심으로 -)

  • Han, Myoung-Heum
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • A study on how fire officer's job satisfaction factors influence space satisfaction rates. This article will conduct regression analysis for the study on these three problems. 'What are the factors of fire officer's job satisfaction?', 'Does space satisfaction rates influence job satisfaction rates?', 'Which job satisfaction factor influence space satisfaction rate?' Therefore, variables were set based on the prior study, and before regression analysis was conducted, variables were purified through analysis on primary factor and reliability analysis, and hypothesis test was done via variable calculation. According to the prior study, factors that influence job satisfaction rates are as following; self-regulation of tasks, ethics and responsibility level, relationship with colleagues, job identity. And regression analysis showed that space satisfaction rates do not influence job satisfaction rates. The writer thinks that it's showing that Korean fire officers tend to prioritize colleague relationship and job identity over space improvements. And the factor that influence job satisfaction rates turned out to be the self-regulation of tasks, and the writer estimates that it's reflecting the hierarchical organization culture of current Korean fire officers. Therefore, future Korean fire station design plans need to consider a space plan that provides fire officer's private self-regulation of tasks.

A Study on the Fire Evacuation Assessment Considering Occupied Environment Variation in Existing Buildings (기존 건축물의 사용승인허가 전·후 거주환경을 고려한 화재피난성능평가 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Kim, In Tae;Kim, Hee Moon;Sim, Hye In
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.105-110
    • /
    • 2016
  • In Korea, fire hazard and risk analysis and response management planning related to existing decrepit buildings, including interior construction and architectural layout revision, due to various occupancy purposes have not been researched or established. Therefore, regulations and technical standards that can manage and reduce fire hazards and risks based on fire hazard analysis and evaluation are required. This study was performed based on a site survey and fire evacuation assessment including performancebased analysis in 3 actual existing buildings to find the life safety issues and provide improvement recommendations.