• Title/Summary/Keyword: fire detection and extinguishing

Search Result 29, Processing Time 0.031 seconds

Development of Loaded Stream Fire Extinguishing Systems for Underground Transmission Cables (지중송전선로 접속부용 미분무 강화액 소화설비의 개발연구)

  • Lee, Sung-Mo
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • Full-scale fire extinguishment tests were conducted to develop loaded stream fire extinguishing systems for protecting underground transmission cables. The dimension of test mock-up was 5.5m height${\times}3m$ width ${\times}6m$ length, and six 154kV OF cables were piled up. Gasoline was used to ignite cates. Linear heat detection cables were installed on top of 154 kV OF cable and discharge nozzles were installed on the top and sidewalls, respectively. As a result, both surface fires and deap-seated fires were extinguished successfully within the specified 3 minutes by discharging loaded stream agent.

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

Analysis on Visibility Range of Forest Fire Detection Facilities for Forest Fire Prevention (산불예방을 위한 감시시설 가시범위 분석에 관한 연구)

  • Lee, Si-Young;An, Sang-Hyun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.157-160
    • /
    • 2008
  • This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it could be whether effective on watching the area where the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

  • PDF

A Study on Fire Recognition Algorithm Using Deep Learning Artificial Intelligence (딥러닝 인공지능 기법을 이용한 화재인식 알고리즘에 관한 연구)

  • Ryu, Jin-Kyu;Kwak, Dong-Kurl;Kim, Jae-Jung;Choi, Jung-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.275-277
    • /
    • 2018
  • Recently, the importance of an early response has been emphasized due to the large fire. The most efficient method of extinguishing a large fire is early response to a small flame. To implement this solution, we propose a fire detection mechanism based on a deep learning artificial intelligence. In this study, a small amount of data sets is manipulated by an image augmentation technique using rotating, tilting, blurring, and distorting effects in order to increase the number of the data sets by 5 times, and we study the flame detection algorithm using faster R-CNN.

  • PDF

A Study on Railway Vehicles Fire Detection using HMI Touch Screen (HMI 터치스크린을 이용한 철도차량용 복합화재수신기 개발 연구)

  • Park, In-Deok;Kim, Chang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-43
    • /
    • 2016
  • Recent social needs for promoting traffic safety increased and the demand social security in economic, increasing the demand for environmentally friendly rail transport. In particular, when train express such as to secure reliability KTX(Korea Train eXpress) from potential disaster(fire) in the train operation caused by the train express running has been very important. Railroad fire extinguishing system is operated to fire exploding before reaching the flashing point more important than early to quickly detect because of CAN(Controller Area Network) communication to fire suppression and fire receiver, interface, fire fighting equipment from HMI((Human Machine Interface) and fire high-performance to research and development for intelligent composite fire receiver is required.

A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium (대규모 실내경기장의 소방방재설비 적용현황 분석)

  • Choi, Dong-Ho;Kim, Choon-Dong;Yang, Jeong-Hoon;Cho, Young-Hum
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.135-145
    • /
    • 2010
  • The objective of this study is to draw basic data for the application of the fire protection planning for the future plan large enclosure buildings in Korea through an analysis of its characteristics by case studies of the domestic and foreign large scale gymnasiums. In this study, domestic building codes for the fire protection are investigated and fire detection systems, fire extinguishing systems, smoke control systems and evacuation systems of three large scale gymnasiums located at Korea and eight foreign countries are compared and analyzed. The results of this study show that infrared light fire detection system and flame detector for spacial characteristics are potentially used in fire protection systems of large scale gymnasiums: dry type sprinkler and sprinkler water gun are adopted in fire detection system; and smoke accumulation system is widely utilized in smoke control system.

  • PDF

Development of a Low-Cost Thermal Image Hidden Fire Detector Using Open Source Hardware (오픈소스 하드웨어를 사용한 저비용 열화상 잔불탐지 장치 개발)

  • Moon, Sangook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1742-1745
    • /
    • 2019
  • Hidden flame detection after allegedly extinguishing a fire cannot be emphasized enough. There are a few commercial hidden fire detection equipments which are imported, but the cost is relatively high. In this contribution, we propose a development of a low-cost, high-performance hidden flame detector using open-source hardware/software. We use Raspberry-pi based hardware board equipped with a TFT touch-screen LCD, a 3G modem, and an attachable battery device altogether integrated in a plastic case fabricated with a 3D printer. The proposed hidden flame detector shows the same performance of a commercial product FLIR E5 while consuming less than a half of the cost.

An Experimental Study on the Comparison of Operating Temperatures in Thermal Detector due to Tunnel Fire (터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구)

  • Roh, Hyeong-Ki;Park, Kwang-Young;Im, Seok-Been
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were and are being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical factors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tunnel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable to measure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor by performing fire simulations under the same condition as a real fire test. From the results, it has been found that the temperature sensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire simulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the currents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishing activities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directions of the fires correctly.

Active Fire Detection Using Landsat 8 OLI Images: A Case of 2019 Australia Fires (Landsat 8 OLI 영상을 이용한 산불탐지: 2019년 호주 산불을 사례로)

  • Kim, Nari;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.775-784
    • /
    • 2020
  • Recent global warming and anthropogenic activities have caused more frequent and massive wildfires with longer durations and more significant damages. MODIS has been monitoring global wildfires for almost 20 years, and GK2A and Himawari-8 are observing the wildfires in East Asia 144 times a day. However, the spatial resolution of 1 to 2 km is not sufficient for the detection of small and medium-size active fires, and therefore the studies on the active fire detection using high-resolution images are essential. However, there is no official product for the high-resolution active fire detection. Hence, we implemented the active fire detection algorithm of Landsat 8 and carried out a high-resolution-based detection of active fires in Australia in 2019, followed by the comparisons with the products of Himawari-8 and MODIS. Regarding the intense fires, the three satellites showed similar results, whereas the weak igniting and extinguishing fires or the fires in narrow areas were detected by only Landsat 8 with a 30m resolution. Small-sized fires, which are the majority in Korea, can be detected by the high-resolution satellites such as Landsat 8, Sentinel-2, Kompsat-3A, and the forthcoming Kompsat-7. Also, a comprehensive analysis together with the geostationary satellites in East Asia such as GK2A, Himawari-8, and Fengyun-3 will help the interoperability and the improvement of spatial and temporal resolutions.