• Title/Summary/Keyword: fire control time

Search Result 356, Processing Time 0.028 seconds

Blasting wave pattern recognition based on Hilbert-Huang transform

  • Li, Xuelong;Wang, Enyuan;Li, Zhonghui;Bie, Xiaofei;Chen, Liang;Feng, Junjun;Li, Nan
    • Geomechanics and Engineering
    • /
    • v.11 no.5
    • /
    • pp.607-624
    • /
    • 2016
  • Rockburst is becoming more serious in Chinese coal mine. One of the effective methods to control rockburst is blasting. In the paper, we monitored and analyzed the blasting waves at different blast center distances by the Hilbert-Huang transform (HHT) in a coal mine. Results show that with the increase of blast center distance, the main frequency and amplitude of blasting waves show the decreasing trend. The attenuation of blasting waves is slower in the near blast field (10-75 m), compared with the far blast field (75-230 m). Besides, the frequency superposition phenomenon aggravates in the far field. A majority of the blasting waves energy at different blast center distances is concentrated around the IMF components 1-3. The instantaneous energy peak shows attenuation trend with the blast center distance increase, there are two obvious energy peaks in the near blast field (10-75 m), the energy spectrum appears "fat", and the total energy is greater. By contrast, there is only an energy peak in the far blast field, the energy spectrum is "thin", and the total energy is lesser. The HHT three dimensional spectrum shows that the wave energy accumulates in the time and frequency with the increasing of blast center distance.

Study on Developing a Monitoring System for Safe Fire Testing (안전한 탄 발사시험을 위한 모니터링 시스템 개발에 관한 연구)

  • Ki Jae-sug
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.05a
    • /
    • pp.453-459
    • /
    • 2005
  • On this research, we show some concrete examples as software design, 2D/3D display, graph display, and gage display to develop a data monitoring system for real time safe fire testing. Developed software which is simulation software for live fire testing, has been designed to display informations about whole test status in a live fire testing, and with this, user can control a live fire testing under the safe environment. Beside, we increase a security by using a authority of user to access on this software. and we develop it based on module designed to apply a requirement of user later on.

  • PDF

Study on Developing a Monitoring System for Safe Fire Testing (안전한 탄 발사시험을 위한 모니터링 시스템 개발에 관한 연구)

  • Ki Jae Sug
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.2
    • /
    • pp.65-72
    • /
    • 2005
  • On this research, we show some concrete examples as software design, 2D/3D display, graph display, and gage display to develop a data monitoring system for real time safe fire testing. Developed software which is simulation software for live fire testing, has been designed to display informations about whole test status in a live fire testing, and with this, user can control a live fire testing under the safe environment. Beside, we increase a security by using a authority of user to access on this software. and we develop it based on module designed to apply a requirement of user later on.

Performance Improvement of the Intelligent System for the Fire Fighting Control using Rule-based and Case-based Reasoning by Clustering in a Ship (규칙 및 클러스터링에 의한 사례기반 추론을 이용한 지능형 선박 화재진압통제시스템의 성능 개선)

  • Hyeon, U-Seok
    • The KIPS Transactions:PartB
    • /
    • v.9B no.3
    • /
    • pp.263-270
    • /
    • 2002
  • Most conventional systems of fire fighting control in a ship have been based on rule-based system in which expert knowledges are expressed with production rules. Renewing and adding of rules is needed continuously for the improvement of the system capability in an already build-up system and such adding and renewing procedures could hinder users from fluent utilization of a system. The author proposes an advanced fire fighting control intelligent system (A-FFIS) using rule-based and carte-based reasoning by clustering to implement conventional hybrid system (H-FFIS). Compared with H-FFIS, new approach with A-FFIS shows that the system proposed here improves fire detection rate and reduces fire detection time.

A Study of Fire Shunt Guidance Based on Wireless Sensor Networks (무선 센서 네트워크 기반의 화재 대피 유도 연구)

  • Kim, Yong-Woo;Kim, Do-Hyeon;Kwak, Ho-Young;Park, Hee-Dong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.11
    • /
    • pp.1547-1554
    • /
    • 2008
  • This paper proposes a fire shunt guidance system model based on rule, it presents suitable shunt route in real-time according to collected fire information of the building inside using wireless sensor networks. So, this system model is composed of the sensor alert module, the behavior suggestion module, and the emergency device control module. The sensor alert module uses rule-base algorithm that monitored the information to collect periodically in wireless sensor networks. And, the behavior suggestion module proposed a suitable behavior, this module supports to judge the fire area with danger sensor list. Additional, the emergency device control module controls a related emergency device according to the suggested behavior and to present on a control screen. We experiment the fire shunt guidance system based on Internet Web for operation verification of the proposed system. Consequently, this study supports people safety with the behavior suggestion according to the context information when an emergency situation happens.

  • PDF

Design for Pressurizing System about Vestibule by Stack Effect & Engineering Analysis - Focused on Case Study - (굴뚝효과와 공학적분석에 의한 부속실 가압시스템 설계 - 사례를 중심으로 -)

  • Kim, Yong-Kwang
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.145-153
    • /
    • 2009
  • We are generally applicate smoke control only vestibule about special escape staircase, it is one of some smoke control model of NFSC 501A. But there are some point at issue in this system. The smoke control system on supervision field of writer is smoke control only vestibule same as the other resemble field. Writer studied in the concrete to find a solution at this issue, and derived a conclusion the most reasonable system on the field is "same time smoke control for staircase and vestibule" by the engineering analysis considering stack effect.

Cracks evolution and multifractal of acoustic emission energy during coal loading

  • Kong, Xiangguo;Wang, Enyuan;He, Xueqiu;Liu, Xiaofei;Li, Dexing;Liu, Quanlin
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.107-113
    • /
    • 2018
  • Coal samples with different joints morphology were subjected to uniaxial compression experiments, cracks evolution was recorded by Nikon D5300 and acoustic emission (AE) energy signals were collected by AEwin Test for Express-8.0. During loading process, coal samples deformed elastically with no obvious cracks changes, then they expanded gradually along the trace of the original cracks, accompanied by the formation of secondary cracks, and eventually produced a large-scale fracture. It was more interesting that the failure mode of samples were all shear shape, whatever the original cracks morphology was. With cracks and damage evolution, AE energy radiated regularly. At the early loading stage, micro damage and small scale fracture events only induced a few AE events with less energy, while large scale fracture leaded to a number of AE events with more energy at the later stage. Based on the multifractal theory, the multifractal spectrum could explain AE energy signals frequency responses and the causes of AE events with load. Multifractal spectrum width (${\Delta}{\alpha}$), could reflect the differences between the large and small AE energy signals. And another parameter (${\Delta}f$) could reflect the relationship between the frequency of the least and greatest signals in the AE energy time series. This research is helpful for us to understand cracks evolution and AE energy signals causes.

A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System" (주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ))

  • Lee, Sung-Ok;Kim, Soo-Am;Shin, Sung-Eun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

A Study on the Integrated Ventilation Control Algorithm for Road Tunnels (다중터널의 통합환기제어 알고리즘 연구)

  • Kim, Tae-Hyung;Hong, Dae-Hie;Chu, Baek-Suk;Kim, Dong-Nam;Keum, Jae-Sung;Kim, Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.405-409
    • /
    • 2008
  • Over 70% of the land is mountains in Korea, so that many roadways naturally includes tunnels. The air flow inside tunnel has complex characteristics, such that a new flow field is formed by following vehicles passing through the tunnel before previous flow field is stabilized. Due to these time delayed-transient characteristics, the ventilation facility requires the complex control algorithm that can handle adaptive and predictive controls. Also, it needs to be closely related to the disaster prevention system. The technology to integrate these system determines the success of TGMS. The pollutant levels exhausted from the vehicles passing through tunnel depend on vehicle years and passing velocity. They also depend on the slope and altitude of the tunnel. In order to solve this problem, an algorithm for estimating the compensating factors for calculating on design capacity of ventilation facilities was developed. Also, an integrated ventilation control algorithm with disaster prevention program to operate several tunnels was developed based on TGMS.

  • PDF

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.