• Title/Summary/Keyword: fire control time

Search Result 359, Processing Time 0.023 seconds

Producing Firefighting Vulnerability Maps Using GIS - A Case Study of Dalseo-gu, Daegu - (GIS를 이용한 화재진압 취약성 지도 제작 - 대구광역시 달서구를 사례로 -)

  • KIM, Sung-Jae;CHOI, Gap-Yong;CHANG, Eun-Mi;SONG, Wan-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.11-20
    • /
    • 2015
  • Fire incidents, which occur every year, cause huge damage to properties and humans. Significant time and costs have been invested in minimizing and responding to such accidents. With the recent advances in the development of spatial information, in the firefighting field, studies have been conducted to effectively bring fires under control using GIS(Geographic Information System). Most of such studies, however, focused on individual analyses of firefighting-related factors, but comprehensive research on the vulnerability factors in fire control activities, a major part of firefighting activity, has yet to be done. This study sought to pinpoint and analyze the factors that obstruct fire controlling, and to gather relevant data and create GIS-based databases. Based on such database, GIS-based overlay analysis was conducted to produce a fire control vulnerability map. The findings of this study will enable a quantitative analysis of firefighting obstruction factors to assist the personnel engaging in firefighting in rational decision-making, such as in formulating a firefighting operation plan for securing golden time.

A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate (대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

A Study on Crack Formation in the K11 Objective Individual Combat Weapon Fire Control System using Analysis of Variance (분산분석을 활용한 K11 복합형소총 사격통제장치 균열발생 원인 연구)

  • Shin, Sang-Sik;Kim, Byeong Kyu;Sim, Chul Bo
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.3
    • /
    • pp.289-298
    • /
    • 2015
  • Purpose: This study examined the problem of crack formation in the fire control system(FCS) of the K11 objective individual combat weapon(OCIW), using design of experiment analysis. Three hypothesis were considered. The first hypothesis is that bolted joint has an effect on impulse caused by firing the weapon and the second hypothesis is that a short time interval of shooting has an effect on impulse and lastly, the third hypothesis is that a positive correlation has between the bolted joint of the FCS and the impulse. Methods: The relationship between the bolted joint and the impulse cause by firing the weapon were examined experimentally. The first and second hypothesis was tested using correlation analysis and the t-test. Results: Using ANOVA, the first null hypothesis was rejected and the alternative hypothesis was accepted. ANONA confirmed the second null hypothesis. Correlation analysis dismissed the last null hypothesis. A positive correlation between the bolted joint and the impulse caused by shooting the weapon was verified. Conclusion: The bolted joint of the K11 FCS and the barrel of the K11 affect the impulse caused by firing the weapon. A positive correlation was established between the bolted joint of the FCS and the impulse on firing the K11 OICW.

Study on Stagnation Factors Analysis and Improvement Methods through an Evacuation Experiment (피난실험을 통한 피난시간 지연요인 분석과 개선방안에 관한 연구)

  • Han, Woon-Hee
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.57-66
    • /
    • 2018
  • The most urgent requirement in the event of disaster and fire in a skyscraper is to establish a system that enables people inside to evacuate safely. Hence, a practical direction needs to give evacuees confidence in the evacuation by reducing the psychological anxiety caused by the relatively large number of people inside and at the same time, the physically prolonged evacuation travel line. Evacuation tests with large numbers of people were conducted three times to solve these challenges and identify phenomena and issues that occurred during the experiment. The results revealed the factors that could cause a delay in evacuation and suggested improvements. The study results of this paper are as follows. First, a recent fire at a multipurpose high-rise resulted in a number of casualties due to a lack of experience with the disaster prevention system. To prevent such cases from occurring in advance, adaptability was achieved by conducting evacuation tests. Second, the data collected in the evacuation simulation statistics and the actual escape drills were compared and analyzed. Third, in the evacuation experiment, a large number of people could not participate in the experiment. The reasons for not participating were analyzed and their impact on the actual evacuation time was confirmed. Fourth, equipment aids were purchased to establish the optimal response measure to the causes of a delay in escape time and the standards for ensuring the safety of the evacuee were specified by developing improvements to minimize the evacuation delay time through comparative before and after analysis of the experiment. These results can be used for fire safety control of skyscrapers to improve the efficiency of evacuation.

A Study on the Application of the Regulation of the Interior Materials in Entertainment Occupancy (다중이용업소의 내장재 규정의 적용에 관한 연구)

  • 이주헌;윤명오;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.100-107
    • /
    • 2001
  • A Interior material, a main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Nonetheless, it has been used recklessly with undue attention to its contribution to fire in particular in entertainment occupancy and causes many victims in fire. Therefore, this study attempts to examine the current use of interior material in Korea and find out what to be improved and enhanced in terms of related regulations. Based on the comparison and analysis of the Korea regulation with those of advanced nations, suggestions are made for an effective and efficient improvement and complement to the current system. What can be suggested from this study are as follows. The use of interior material should be controlled under the unified regulation of fire-safety codes. Code should be set up so that the current construction enforcement should be applied in retroactive to those entertainment buildings that obtained a license prior to the implementation of the system certifying that the building is fire-resistant and fire-protective. The legislation should be made to control the fire-protection facilities of small-sized, underground entertainments. It should be obliged to present the blueprint displaying the use of interior material at the time of changing occupancy. Or, it should be compelled to report changes that go way without permit to the administrative office. A compulsory provision should be set up to have a fire-resistant performance to movable furniture. The classification index designating the fire hazard of interior material by flame spread rate and smoke toxicity and its test method should be established.

  • PDF

A Study on the Satisfaction of Non Face to Face Real Time Education Focused on Firefighter in COVID-19 (코로나19 상황에서 소방공무원을 대상으로 한 비대면 실시간 교육 만족도에 관한 연구)

  • Park, Jin Chan;Baek, Min Ho
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.91-103
    • /
    • 2022
  • Purpose: After COVID-19, changes in the educational ecosystem take place and fire service academy education system have shifted from face-to-face into non fact-to-face. So, the educational effect of fire officials is decreased and the satisfaction level is also decreased. In this study, we want to examine the current status of non-face-to-face real-time remote education and supplement the problems to improve the educational methods, the educational environment, etc. Method: This study is an independent variable that affects non-face-to-face real-time remote education, consisting of education system environment, self-efficacy of computers, contents (education contents, structure, design, etc.), and proper interaction. A dependent variable was selected with satisfaction for non-face-to-face real-time remote education. In addition, it was selected and analyzed as an active property of learning motivation and learning attitude as control variables. Result: The better the content and the more active the learning motivation and the attitude toward learning, the higher the satisfaction of non-face-to-face real-time remote education, and the more active the learning motivation and the attitude toward learning, the more positive the computer self-efficacy and the satisfaction of learning Conclusion: In order to increase the satisfaction of non-face-to-face real-time education due to COVID-19, education designers or professors need to provide non-face-to-face education contents that can increase the aggressiveness of their learning motivation and learning attitude, and to increase the satisfaction of education for learners by increasing computer self-efficacy through pre-education of non-face-to-face education systems.

Efficient Multicasting Mechanism for Mobile Computing Environment (산불 발생지역에서의 산불 이동속도 예측 및 안전구역 확보에 관한 연구)

  • Woo, Byeong-hun;Koo, Nam-kyoung;Oh, Young-jun;Jang, Kyung-sik;Lee, Kang-whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.89-92
    • /
    • 2015
  • In this paper, we propose a method to reduce the fire suppression time. Our suggestions can secure a safe area according to the diffusion path and speed of the fire, forest fire prediction minimize casualties and property damage forests. The existing path prediction method wildfire spread predict the wildfire spread model and speed through topography, weather, fuel factor and the image information. In this case, however, occur to control a large mountain huge costs. Also Focus on the diffusion model predictions and the path identified by the problem arises that insufficient efforts to ensure the safe area. In this paper, we estimate the moving direction and speed of fire at a lower cost, and proposes an algorithm to ensure the safety zone for fire suppression. The proposed algorithm is a technique to analyze the attribute information that temperature, wind, smoke measured over time. According to our algorithm forecast wildfire moving direction and ensure the safety zone. By analyzing the moving speed and the moving direction of the simulated fire in a given environment is expected to be able to quickly reduce the damage to the forest fire fighters.

  • PDF

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

A Study on the Systemic Improvement for the Enactment and Revision of the National Fire Safety Code (국가화재안전기준(NFSC)의 제·개정 시스템 개선에 관한 연구)

  • Song, Young-Joo;Kim, Tae-Woo;Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • The National Fire Safety Code (NFSC) sets forth the installation methods and technical standards of firefighting facilities. This information is stipulated in the attached Table 1 of the Enforcement Decree of the Act on Fire Prevention and Installation, Maintenance and Safety Control of Fire-Fighting Systems. The NFSC serves as a foundation for fire prevention and public safety. However, the current version of the NFSC has been under scrutiny due to its delayed enactment and revision process. This is because of its structural inflexibility, time-consuming procedures, and mixed usage of both performance and technical standards. Furthermore, there are difficulties with keeping its unique specialties due to the absence of a specialized, permanent independent entity that enacts, revises, and maintains its standards. Moreover, the NFSC lacks collectivity, openness, and consistency. Therefore, to overcome the aforementioned obstacles, this study investigates the operational and legal status of the NFSC and the problems regarding its enactment and revision process. Further, it presents suggestions for system improvement by analyzing and comparing the information with domestic and foreign counterparts dedicated to managing their similar technical NFSC standards. First, the study recommends that the legal performance and technical standards mixed within the current NFSC should be separated. Second, the enactment and revision of technical standards should be implemented by the private sector and not by the government. Third, technical standards should adopt a user-oriented approach for the code system.