The Measurement of the Combustible Properties of tert-Butylbenzene for the Improvement of MSDS (Material Safety Data Sheet) (MSDS 개선을 위한 tert-Butylbenzene의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.25-30
    • /
    • 2017
  • Because of the vertical combustion characteristics of combustible substances, accurate substance safety information for their safe use, handling and transportation is essential. The flash point, fire point, explosion limits and autoignition temperature (AIT) are important safety parameters which need special attention in chemical plants and laboratories that handle dangerous materials. In this study, tert-butylbenzene which is widely used as an intermediate material in the chemical industry was selected. For the reliability of the flammable properties of tert-butylbenzene, this study was investigated the explosion limits of tert-butylbenzene in the reference data. The flash points, fire points and AITs by the ignition delay time for tert-butylbenzene were experimented. The lower flash points of tert-butylbenzene by using the Setaflash and Pensky-Martens closed-cup testers measured $39^{\circ}C$ and $44^{\circ}C$, respectively. The flash points of tert-butylbenzene by using the Tag and Cleveland open cup testers are measured $51^{\circ}C$ and $54^{\circ}C$. And the fire points of tert-butylbenzene by the Tag and Cleveland open cup testers were $54^{\circ}C$ and $58^{\circ}C$ respectively. The AIT of tert-butylbenzene measured by the ASTM 659E tester was measured as $450^{\circ}C$. The lower explosion limit of $39^{\circ}C$ which measured by the Setaflash flash point tester was calculated to be 0.68 vol%.

Prediction of Explosion Limits of Aldehydes Using Chemical Stoichiometric Coefficients and Heats of Combustion (연소열 및 화학양론계수를 이용한 알데히드류의 폭발한계의 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.5-11
    • /
    • 2015
  • The explosion limit is one of the major combustion properties used to determine the fire and explosion hazards of the flammable substances. The explosion limit of aldehydes have been shown to be correlated the heat of combustion and the chemical stoichiometric coefficients. In this study, the lower explosion and upper explosion limits of aldehydes were predicted by using the heat of combustion and chemical stoichiometric coefficients. The values calculated by the proposed equations agreed with literature data above determination coefficient 0.99. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the aldehydes.

Study on Explosion Behavior of Air-born Rice Bran Dusts according to Ignition Energy (점화에너지 변화에 따른 쌀겨분진의 폭발 거동에 관한 연구)

  • 김정환;김현우;현성호;백동현
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.26-32
    • /
    • 1999
  • We had investigated combustion pro야$\pi$ies of rice bran dusts. Decomposition of rice bran d dusts with temperature were investigated using DSC and the weight loss according to t temperature using TGA in order to find the thermal hazard of rice bran dusts, and the p properties of dust explosion in variation of their dust with the same particle size. Using H Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after m making dust disperse by compressed air, dust explosion experiments have been conducted by v varying concen$\sigma$ation and size of rice br뻐 dust. According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation 때d heating value for used particle size. But i initiation temperature of heat generation decreased with high heating rate whereas d decomposition heat increased with particle size. Also, the explosion pressure was increased as t the ignition energy increased and average maximum explosion pressure was 13.5 kgv'cnt for 5 BJ/60 mesh and 1.5 뼈Ie미 dust concentration.

  • PDF

Process Hazard Review and Consequence Effect Analysis for the Release of Chlorine Gas from Its Storage Tank (염소저장탱크에서의 가스 누출시 공정위험검토 및 결과영향분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.61-73
    • /
    • 2003
  • Most of the accidents occurred from the chemical plants are related to the catastrophic gas release events when the large amount of toxic materials is leaked from its storage tank or transmitting pipe lines. In this case, the greatest concerns are how the spreading behaviors of leakages are depended on the ambient conditions such as air stability and other environmental factors. Hence, we have focused on the risk assessments and consequential analysis for chlorine as an illustrative example. As appeared in the result, Fire & Explosion Index depicted it a bit dangerous with presenting the comprehensive degrees of hazard 90.7. And as a result of Phast6.0/ALOHA, the trends of each scenario appeared considerably identical although there are some differences in the resulting effects according to the input data for the Gas Model. The consequence analysis is performed numerically based on the dense gas mode. In the future, using more correct input data, material properties, and topographical configuration, the method of this research will be useful for the guideline of the risk assessment when the release of toxicants breaks out.

Prediction of the Net Heats of Combustion of Organic Halogenated Compounds based on the Atomic Contribution Method (원자기여법에 근거한 유기 할로겐 화합물의 순연소열 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.7-12
    • /
    • 2003
  • The heat of combustion is one of the major physical properties used to determine the fire and explosion hazards of the flammable substances. Empirical equations have been developed to pre-dict the net heats of combustion of organic halogenated compounds based on the atomic contribution method. The method developed in this study was compared with Cardozo's method and Hanley's method. As can be seen from the average absolute deviation(A.A.D.), the proposed equation was found to be best. The proposed equation may serve as an estimation scheme for the heats of combustion of the other organic halogenated compounds.

A Study on the Fire Resistance and Mechanical Properties of High Strength Concrete Mixed Hybrid Fibers (하이브리드 섬유 혼입 고강도 콘크리트의 내화 및 역학적 특성에 관한 연구)

  • Shin, Young-Suk;Li, Zhi-Min;Yoo, Myung-Hwan;Cho, Cheol-Hee;Kim, Jeong-Sup
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.6
    • /
    • pp.67-75
    • /
    • 2010
  • In this paper, by using steel fiber, polypropylene fiber and these two hybrid fibers, the fire resistance performance and explosive properties of High Strength Concrete (HSC) with specified compressive strength of 40MPa are discussed. The paper also examines the bending resistance of the beam and the shearing resistance properties of non-reinforced HSC beam. This research helps to clarify the fire resistance of fiber HSC and its anti-explosion methods. The test results show that crack generation, explosion and carbonization can be effectively restrained when HSC is mixed with hybrid fibers under high temperature; furthermore, the maximum internal force and ductility are increased and the initial cracking can be restrained in the mechanical test.

The Measurement and Investigation of Fire and Explosion Properties for Cyclohexane (사이클로헥산의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.75-81
    • /
    • 2011
  • For the safe handling of cyclohexane, the explosion limit at $25^{\circ}C$ and the temperature dependence of the explosion limits were investigated. Flash point and AIT(autoignition temperature) for cyclohexane were experimented. By using the literatures data, the lower and upper explosion limits of cyclohexane recommended 1.0 Vol% and 9.0 Vol%, respectively. Moreover lower flash points of cyclohexane recommended $-20^{\circ}C$. It was measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for cyclohexane, and the experimental AIT was $255^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of cyclohexane is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

Appropriateness of MSDS by Means of the Measurement of Combustible Properties of Anisole (아니솔의 연소특성치의 측정에 의한 MSDS의 적정성)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.20-24
    • /
    • 2015
  • For the safe handling of anisole, this study was investigated the explosion limits of anisole in the reference data. The flash points and auto-ignition temperatures (AITs) by ignition delay time were experimented. The lower flash points of Anisole by using closed-cup tester were experimented in $39^{\circ}C$ and $42^{\circ}C$. The lower flash points of Anisole by using open cup tester were experimented in $50^{\circ}C$ and $54^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for Anisole. The AIT of Anisole was experimented as $390^{\circ}C$. The lower explosion limit (LEL) by the measured the lower flash point for Anisole were calculated as 1.07 Vol%.

A Study on How to Evaluate Appropriate Ventilation Rate of Indoor Facility Handling Hazardous Substances by Their Flammable and Explosive Properties (유해화학물질을 취급하는 실내시설에서의 인화폭발성에 따른 적정 환기량 산정에 대한 연구)

  • Mansu Park;Cheong-Min Seo;Hyo-Soub Yoon;Kyoshik Park
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.293-301
    • /
    • 2024
  • Purpose: Ministry of Environment statistics reveals more than 132 fire·explosion accidents in South Korea between 2014 and 2023. Among them, fire and/or explosion accidents are very impactive in their scale and consequence. This study aims to suggest a new method of reasonable way to calculate the ventilation rate of indoor facility handling hazardous chemicals based on their inflammability. Method: A new method to calculate the ventilation rate is based on the physicochemical properties of the chemicals handled, which is more reasonable compared with the current regulation based only on the floor area of the facility. Result: Considering the physicochemical properties, 178 chemicals based on their inflammability were studied and 168(94%) met the criteria for the current regulation. Some materials have been shown to require too much or too little ventilation rate. Conclusion: Through this study, a reasonable method of calculating the required ventilation rate was proposed. This should be applied to ensure the safety of workers to deal chemicals.