• 제목/요약/키워드: fire alarm system

검색결과 163건 처리시간 0.028초

퍼지논리 및 다중신호를 이용한 화재감지시스템의 개발 (The Development of Fire Detection System Using Fuzzy Logic and Multivariate Signature)

  • 홍성호;김두현
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2004
  • This study presents an analysis of comparison of P-type fire detection system with fuzzy logic-applied fire detection system. The fuzzy logic-applied fire detection system has input variables obtained by fire experiment of small scale with K-type temperature sensor and optical smoke sensor. And the antecedent part of fuzzy rules consists of temperature and smoke density, and the consequent part consists of fire probability. Also triangular fuzzy membership function is used for input variables and fuzzy rules. To calculate the final fire probability a centroid method is introduced. A fire experiment is conducted with controlling wood crib layer, cigarette to simulate actual fire and false alarm situation. The results show that peak fire probability is 25[%] for non-fire and is more than 80[%] for fire situation, respectively. The fuzzy logic-applied fire detection system suggested here is able to distinguish fire situation and non-fire situation very precisely.

사례 분석을 통한 IoT 기반 화재탐지시스템의 화재 감지신호 특성 (A Case Study of the Characteristics of Fire-Detection Signals of IoT-based Fire-Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권3호
    • /
    • pp.16-23
    • /
    • 2022
  • This study aims to provide a fundamental material for identifying fire and no-fire signals using the detection signal characteristics of IoT-based fire-detection systems. Unlike analog automatic fire-detection equipment, IoT-based fire-detection systems employ wireless digital communication and are connected to a server. If a detection signal exceeds a threshold value, the measured values are saved to a server within seconds. This study was conducted with the detection data saved from seven fire accidents that took place in traditional markets from 2020 to 2021, in addition to 233 fire alarm data that have been saved in the K institute from 2016 to 2020. The saved values demonstrated variable and continuous VC-Signals. Additionally, we discovered that the detection signals of two fire accidents in the K institution had a VC-Signal. In the 233 fire alarms that took place over the span of 5 years, 31% of smoke alarms and 30% of temperature alarms demonstrated a VC-Signal. Therefore, if we selectively recognize VC-Signals as fire signals, we can reduce about 70% of false alarms.

LSTM-based Early Fire Detection System using Small Amount Data

  • Seonhwa Kim;Kwangjae Lee
    • 반도체디스플레이기술학회지
    • /
    • 제23권1호
    • /
    • pp.110-116
    • /
    • 2024
  • Despite the continuous advancement of science and technology, fire accidents continue to occur without decreasing over time, so there is a constant need for a system that can accurately detect fires at an early stage. However, because most existing fire detection systems detect fire in the early stage of combustion when smoke is generated, rapid fire prevention actions may be delayed. Therefore we propose an early fire detection system that can perform early fire detection at a reasonable cost using LSTM, a deep learning model based on multi-gas sensors with high selectivity in the early stage of decomposition rather than the smoke generation stage. This system combines multiple gas sensors to achieve faster detection speeds than traditional sensors. In addition, through window sliding techniques and model light-weighting, the false alarm rate is low while maintaining the same high accuracy as existing deep learning. This shows that the proposed fire early detection system is a meaningful research in the disaster and engineering fields.

  • PDF

반도체공장의 NFPA921에 의한 비화재보 원인조사 방안 (A Study on the Causes of False Alarm by NFPA921 in Semiconductor Factory)

  • 홍상혁;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.87-94
    • /
    • 2023
  • This study analyzed and identified various causes of caustic alarms of 163 fire detectors that occurred from January 2019 to December 2021 at domestic semiconductor manufacturing plants equipped with about 30,000 fire detectors, and proposed a new non-fire prevention cause investigation plan by applying the NFPA 921 scientific methodology. The results of the study are as follows. First, in terms of necessary recognition and problem definition, an analog detector and an integrated monitoring system were proposed to quickly determine the location and installation space information of the fire detector. Second, in order to prevent speculative causes and errors in various analyses in terms of data analysis and hypothesis establishment, non-fire reports were classified into five by factor and defined, and the causes of occurrence by factor were classified and proposed. Finally, in terms of hypothesis verification and final hypothesis selection, a non-fire prevention improvement termination process and a final hypothesis verification sheet were proposed to prevent the cause from causing re-error.

An Intelligent Fire Detection Algorithm for Fire Detector

  • Hong, Sung-Ho;Choi, Moon-Su
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 2012
  • This paper presents a study on the analysis for reducing the number of false alarms in fire detection system. In order to intelligent algorithm fuzzy logic is adopted in developing fire detection system to reduce false alarm. The intelligent fire detection algorithm compared and analyzed the fire and non-fire signatures measured in circuits simulating flame fire and smoldering fire. The algorithm has input variables obtained by fire experiment with K-type thermocouple and optical smoke sensor. Also triangular membership function is used for inference rules. And the antecedent part of inference rules consists of temperature and smoke density, and the consequent part consists of fire probability. A fire-experiment is conducted with paper, plastic, and n-heptane to simulate actual fire situation. The results show that the intelligent fire detection algorithm suggested in this study can more effectively discriminate signatures between fire and similar fire.

Wireless Sensor Networks based Forest Fire Surveillance System

  • Son, Byung-Rak;Kim, Jung-Gyu
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.123-126
    • /
    • 2005
  • Wireless Sensor Networks will revolutionize applications such as environmental monitoring, home automation, and logistics. We developed forest fire surveillance system. In this paper, Considering the fact that in Korea, during November to May, forest fires occur very frequently causing catastrophic damages on the valuable environment, Although exists other forest fire surveillance system such as surveillance camera tower, infrared ray sensor system and satellite system. Preexistence surveillance system can't real-time surveillance, monitoring, database and automatic alarm. But, forest fire surveillance system(FFSS) support above. In this paper, we describes a system development approach for a wireless sensor network based FFSS that is to be used to measure temperature and humidity as well as being fitted with a smoke detector. Such a device can be used as an early warning fire detection system and real-time surveillance in the area of a bush fire or endangered public infrastructure. Once the system has being development, a mesh network topology will be implemented with the chosen sensor node with the aim of developing a sophisticated mesh network.

  • PDF

중계기점검자동복구기 Grabber에 관한 연구 (The study on Grabber of Restoration worker for Dispersion relay)

  • 전중함;박종탁;김일중
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.147-150
    • /
    • 2012
  • This study restoration worker for dispersion relay in R-Type fire alarm system. Restoration worker very good instrument for an fire system inspector. When inspector check for fire system someone need reset for fir system to normal state. This chain of action is frequent and troublesome. In this case, If we can automatic reset for fire system it's restoration worker. This paper settlement on the problem for reset fire system. Design, make grabber for restoration worker. The test offer proof possibility restoration worker.

  • PDF

MANGO ZDK 개발툴을 이용한 화재감지용 통신 프로토콜 개발 (A Design of Communication Protocol for Fire Detection by Using MANGO ZDK Development Tool)

  • 윤동열;주영훈;김성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.426-429
    • /
    • 2007
  • When a fire happens in builds or apartments, peoples are tend to be caught in dangerous situations owing to the failure of searching escape route to the outside. In this work, an efficient fire detection and alarm system which makes it possible for the escapers to take adequate actions is proposed. The proposed system consists of two parts. One is fire detection modules which are located at each compartments in a building. The other is fire warning modules equipped with portable flashes having ability of visual/voice warning. Fire detection information is transmitted between each modules wirelessly. In this work, an efficient communication protocol for sensor network-based fire detection system is proposed and its feasibility is verified by practical experiments using MANGO ZDK Development tools

  • PDF

RED Filtering과 Mask Matching을 이용한 화재위치 인식 (Recognition of Fire Position and Region using RED Filtering and Mask Matching)

  • 백동현;김장원
    • 한국화재소방학회논문지
    • /
    • 제19권4호
    • /
    • pp.64-68
    • /
    • 2005
  • 본 논문에서는 방범 및 보안설비로 설치된 CCD카메라로 화재가 발생한 지역의 영상을 획득하였을 때, 빠른시간 안에 화재 발생위치를 인식하고 경보를 발령할 수 있는 시스템을 연구하였다. 화재발생 지역 중 불꽃부위만을 효과적으로 추출할 수 있는 방법으로 RED Filtering법을 제안하였고, 불꽃부위 경계를 추출하기 위하여 2치 영상기법을 적용하였으며, Mask추출과 정합을 이용하여 화재가 발생한 위치 및 지역을 인식할 수 있도록 하였다. 실험결과, 불꽃과 복잡한 경계부분도 효과적으로 추출되었으며 원영상과의 정합을 통해 화재 발생위치를 효과적으로 인식하여 제안한 알고리즘의 타당성을 확인하였다