• Title/Summary/Keyword: fire accidents

Search Result 754, Processing Time 0.03 seconds

Study on Predictable Program of Fire.Explosion Accident Using Poisson Distribution Function & Societal Risk Criteria in City Gas (Poisson분포를 이용한 도시가스 화재 폭발사고의 발생 예측프로그램 및 사회적 위험기준에 관한 연구)

  • Ko, Jae-Sun;Kim, Hyo;Lee, Su-Kyoung
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.6-14
    • /
    • 2006
  • The data of city gas accidents has been collected and analysed for not only predictions of the fire and explosion accidents but also the criteria of societal risk. The accidents of the recent 11 years have been broken up into such 3 groups roughly as "release", "explosion", "fire" d 16 groups in detail. Owing to the Poisson probability distribution functions, 'careless work-explosion-pipeline' and 'joint loosening & erosion-release-pipeline' items respectively have turned out to record the lowest and most frequency among the recent 11-years accidents. And thus the proper counteractions must be carried out. In order to assess the societal risks tendency of the fatal gas accidents and set the more obvious safety policies up, the D. O. Hogon equation and the regression method has been used to range the acceptable range in the F-N curve of the cumulative casualties. The further works requires setting up successive database on the fire and explosion accidents systematically to obtain reliable analyses. Also the standard codification will be demanded.

Study on Probabilistic Analysis for Fire·Explosion Accidents of LPG Vaporizer with Jet Fire (Jet Fire를 수반한 국내외 LPG 기화기의 화재·폭발사고에 관한 확률론적 분석에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • This study collected 5,100 cases of gas accident occurred in Korea for 14 years from 1995 to 2008, established Database and based on it, analyzed them by detailed forms and reasons. As the result of analyzing the whole city gas accidents with Poisson analysis, the item of "Careless work-Explosion-Pipeline' showed the highest rate of accidents for the next 5 years. And, "Joint Losening and corrosion-Release-Pipeline" showed the lowest rate of accident. In addition, for the result of analyzing only accidents related to LPG vaporizer, "LPG-Vaporizer-Fire" showed the highest rate of accident and "LPG-Vaporizer-Products Faults" showed the lowest rate of accident. Also, as the result of comparing and analyzing foreign LPG accident accompanied by Jet fire, facility's defect which is liquid outflow cut-off device and heat exchanger's defect were analyzed as the main reason causing jet fire, like the case of Korea, but the number of accidents for the next 5 years was the highest in "LPG-Mechanical-Jet fire" and "LPG-Mechanical-Vapor Cloud" showed the highest rate of accidents. By grafting Poisson distribution theory onto gas accident expecting program of the future, it's expected to suggest consistent standard and be used as the scale which can be used in actual field.

Case Studies of Firefighter Burns Safety Accident during Fire-fighting Activities (현장 소방활동 중 소방공무원 화상사고 사례 분석 연구)

  • Sin-woong, Choi;So Yun, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.136-147
    • /
    • 2022
  • The purpose of this study is to analyze four cases of firefighter burns in various fire scenes and to find prevention measures to decrease firefighter injuries. Among the analysis reports prepared by the National Fire Research Institute of Korea from 2016 to 2020, four burn-related accidents are summarized and the main causes are conveyed. The four accidents include second-degree burns from using extinguishers during containment of fires; nine firefighters burned due to re-ignition in the LPG car repair shop; two firefighters injured with third-degree burns from using fire extinguishers during life-saving events in residential housing; and injuries from the radiant heat of the tank BLEVE near the factory fire. These cases are comprehensively investigated in their respective scenes and analyzed based on the fire site investigation reports from the fire department and related theoretical explanations of risk for each accident scene. In the third case study, some experimental research is conducted to evaluate the risk involved with the use of safety gloves. This is evaluated by reviewing Fire Tactics and Standard Operational Procedures (SOP) to determine improvements and recommendations for an efficient firefighting response. Results show that the main causes of burn accidents are the insufficient use of personal protective equipment (PPE), such as safety gloves, and the failure to follow firefighting tactics or SOPs. Through the accident investigation and assessment, it is concluded that to reduce the frequency of burn accidents, the performance of firefighting equipment, SOPs, protection tactics, and safety policy systems require improvement.

A study on the relationship among traffic accidents, fire occurrences and tunnel characteristics in local road tunnels (국내 도로터널내 발생 교통사고, 화재사고 및 터널특성 관계 연구)

  • Kim, Hyo-Gyu;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.3
    • /
    • pp.199-211
    • /
    • 2004
  • As the length of local tunnels is getting longer, the demand for tunnel safety attracts more attention. But only a few information can be found concerning traffic and fire accidents occurred in local tunnel, and full-fledged studies had not been carried out to fulfill the expectation of the tunnel users. This study aims at collecting and analyzing the data on traffic and fire accidents in local road tunnels and providing the fundamental data for the tunnel fire safety evaluation. Focus is placed on quantifying the relationship among traffic accidents, fire occurrences and tunnel characteristics.

  • PDF

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

A Comparative Analysis on Accident Occurrences in Korea and Japan (한일 사고 발생 실태 비교 분석)

  • Lee Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.1-12
    • /
    • 2005
  • June 1, 2004, National Emergency Management Agency was established, and one of its aims is to reduce the percentage of accident occurrence and damage scale to that of developed countries in 10 years. In this paper, Korea is compared with Japan in the view of actual conditions of accident occurrence in order to compare Korea with developed countries. In the case .of Korea, traffic accidents, fire accidents, careless accidents, drowning accidents, climbing accidents occur frequently. Decreasing these accidents is a major target to reduce the accident occurrence. Also, home accidents of babies and elders who are unable to avoid dangers are frequent. Studies focusing on those related accidents are required.

A Study of Burn Accidents in Children towards Developing a Program for Prevention (어린이 화상사고의 실태와 예방대책 프로그램 개발에 대한 연구)

  • Han, Jeong-Seok;Seo, Mi-Hye
    • The Korean Nurse
    • /
    • v.36 no.4
    • /
    • pp.61-74
    • /
    • 1997
  • This study is a descriptive study which was done to examine the circumstances surrounding burn accidents in children in order to develop a burn prevention program. The subjects for the study were the mothers of 107 children admitted to two burn specialty hospitals in seoul and the mothers of 172 healthy children attending day care or kindergarten. The tool used in the study was developed by the researchers, pretested and refined. Cronbach's alpha was 0.72. Data collection was done between November 1995 and April 1996. Statistically analysis was done using SAS Version 6.04 and the data was analyzed using test, chi square, regression and logistic analysis. A suumary of the results shows the following : Eighty percent of the children in both groups lived in nuclear families but comparatively more of the children with burn accidents lived in apartments. More of the parents in the group of healthy children had university education and held white collar or professional jobs, while the parents of the children with burn accidents were slightly younger than the parents of the healthy children. but not significantly younger. A significantly greater number of families of children with burn accidents had more than one child and the characteristics of the children with burn accidents that they were more frequently boys, either first or last born and very active. Most of the burn accidents occurred in fall or winter. sometime between noon and midnight and the majority occurred in the home and were caused by hot liquid. In 86% of the cases emergency care was not given at home but the child was brought to the hospital emergency unit. Most of the burns were second degree or greater. involved the arms or legs. required admission, and 41.5% occurred when the parents were preparing or eating meals. In a test of knowledge of preventive measures, the mothers of children who had suffered burn accidents scored slightly higher than the mothers who had no experience with burn accidents, but this was not statistically significant. As to what to do in the case of a fire, the mothers of the healthy children had more knowledge about who to notify. but 70% of the mothers in both groups did not know how to escape from the house if it was of fire. 80 to 96% did not know what do to in case of a fire, such as rolling if clothes were on fire. 80% did not know what emergency care to give for a burn, and 74 to 87% did not know when it is appropriate to try to put out a fire. It can be concluded from this study that. since the results show that the most frequent situation which resulted in burn accidents was when the parents were not aware of the danger of burns or were not paying attention to the child. and when there were no protective devices to prevent burns. and that accidents most frequently occurred at home. the most effective way of preventing accidents is to develop in the parents a "safety mind", Since burn accidents in children are usually more severe than in adults. the physical. emotional. psychological and social damage is greater. In order to develop and awareness of this in the general public. the use of mass media. books and pamphlets and other educational media that provide education on prevention of burn accidents need to be utilized.

  • PDF

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Fire hazards in tunnels and underground installations

  • Opstad Kristen
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.27-32
    • /
    • 2003
  • Fire accidents in tunnels and underground installations have resulted in significant loss in terms of life and costs. Several large research projects are launched in Europe to find cost effective ways to upgrade and make such installation more robust against accidents from fires and explosions. For one single tunnel, severe fire accidents are rare and operators and users will have very limit experience, when they do occur. There is a trend to solve the problem with high tech instrumentation and monitoring techniques and to rely on the fire brigade to play a major role in the rescue operation. These precautionary measures are very difficult to validate for the severe fires. For protection against the most critical fires, the safety has to be considered in the design of the tunnel and the technical installation validated so that it operates as indented.

  • PDF

A Study on Securing Safety for High Rise Building Fires - Applying Active Fire Escape Systems -

  • Myung Sik, Lee;Sung Jae, Han
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.227-240
    • /
    • 2022
  • Under the Korean Enforcement Decree of the Building Act, all high story apartment houses more than 5 stories high are mandated to install a fire evacuation system to ensure safe evacuation from fire accidents and providing quick and easy bidirectional escape route when main entrance is blocked by flame or toxic smoke. However, the current fire evacuation system shows a lack of understanding from residents and thus is widely ignored for having insufficient safety functions, especially vis-à-vis fire emergencies. Studies have found that an alternative evacuation method, the escapable fire evacuation system, has been analyzed for safety evaluation compared with the conventional passive fire escape system and can bring efficient and safer solutions, providing high rise residents escape from fire accidents. Evaluation for safety evacuation has been performed by the Fire Dynamics Simulation and applying Pathfinder simulation. This resulted in providing appropriate escape routes within the safety escape time and allowed for people in high rise building fires to get to safety.