• Title/Summary/Keyword: fire accident

Search Result 703, Processing Time 0.024 seconds

Applicability of CO2 Extinguishing System for Ships (질식사고 방지용 CO2 소화설비의 선박 적용성)

  • Ha, Yeon Chul;Seo, Jung Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.294-300
    • /
    • 2017
  • The offshore installations and ships are the structures most likely to be exposed to hazards such as hydrocarbon fire and/or explosion. Developing proactive measures to prevent the escalation of such events thus requires detailed knowledge of the related phenomena and their consequences. $CO_2$ extinguishing systems are extensively used for fire accidents of on-and offshore installations because of outstanding performance and low cost. There is, however, the risk of carbon dioxide system which enumerates many of the fatalities by suffocation associated with industrial fire protection requirements. Therefore, the aim of this study is to perform the prediction of fire suppression characteristics of the carbon dioxide system in realistic enclosed compartment area of ships and propose $CO_2$ extinguish fire fighting system for preventing suffocation accidents during fire fighting. According to CFD calculations, it can be observed and assessed that various fire profiles with $CO_2$ and $O_2$ mole fraction in the target enclosed compartment area are applicable within the proposed system. Additionally, the design of fire safety system of ships and offshore installations can utilize ventilation system and/or layout arrangement through the proposed system.

Modelling of the fire impact on CONSTOR RBMK-1500 cask thermal behavior in the open interim storage site

  • Robertas Poskas;Kestutis Rackaitis;Povilas Poskas;Hussam Jouhara
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2604-2612
    • /
    • 2023
  • Spent nuclear fuel and long-lived radioactive waste must be carefully handled before disposing them off to a geological repository. After the pre-storage period in water pools, spent nuclear fuel is stored in casks, which are widely used for interim storage. Interim storage in casks is very important part in the whole cycle of nuclear energy generation. This paper presents the results of the numerical study that was performed to evaluate the thermal behavior of a metal-concrete CONSTOR RBMK-1500 cask loaded with spent nuclear fuel and placed in an open type interim storage facility which is under fire conditions (steady-state, fire, post-fire). The modelling was performed using the ANSYS Fluent code. Also, a local sensitivity analysis of thermal parameters on temperature variation was performed. The analysis demonstrated that the maximum increase in the fuel load temperatures is about 10 ℃ and 8 ℃ for 30 min 800 ℃ and 60 min 600 ℃ fires respectively. Therefore, during the fire and the post-fire periods, the fuel load temperatures did not exceed the 300 ℃ limiting temperature set for an RBMK SNF cladding for long-term storage. This ensures that fire accident does not cause overheating of fuel rods in a cask.

Development of Probabilistic Fatality Estimation Code for Railway Tunnel Fire Accidents (철도터널 화재시 승객 생존율 예측을 위한 확률론적 평가코드 개발연구)

  • 곽상록
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.445-450
    • /
    • 2004
  • Tunnel fire accident is one of the critical railway accidents, together with collision and derailment. For the safe operation many tunnel design guidelines are proposed but many Korean railway tunnels do not satisfy these guidelines. For the safety improvement, current safety level is estimated in this study. But so many uncertainties in major input parameters make the safety estimation difficult. In this study, probabilistic techniques are applied for the consideration of uncertainties in major input parameters. As results of this study, probabilistic safety estimation code is developed.

  • PDF

Influential Factors on patient assessment Execution Given Emergency Medical Care Transportation of Cerebro-Vascular Accident Patients (뇌혈관질환 환자 이송 시 환자평가 시행에 미치는 요인)

  • Roh, Sang-Gyun;Kim, Jee-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.178-181
    • /
    • 2012
  • 이 연구 대상자는 일개 대학병원 응급의료센터로 소방구급대를 통해 내원한 환자 중 컴퓨터 단층촬영으로 뇌졸중으로 진단된 환자에서 이송 시 환자평가 시행에 영향을 미치는 요인을 분석한 연구이다. 연구결과 환자 평가에 영향을 미치는 요인은 환자분류(응급, 비응급, 지연), 의식상태(AVPU 척도)보다는 구급대원 자격별이 병원 전 뇌졸중 환자 이송 시 환자평가 시행에 영향을 미치는 것으로 확인되었다.

  • PDF

A Study on the multiplex refuge facility according to visiter's behavior characteristics (관람객 행동 특성에 따른 멀티플렉스 피난시설 개선방안 연구)

  • Cho Young-Jun;Kim Taek-Woo;Kim Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.187-190
    • /
    • 2005
  • By the rapid technological advance and social needs, demand of Multi Function Facility is on the increase. The multiplex is an alternative of them. In case of fire, special function of facility nay result in terrible accident. Therefore, literature and regulations survey on the multiplex were enforced, Multiplex facilities in Daejeon City were surveyed, and reformation of regulation and structural system were suggested in this study.

  • PDF

Study on the Improvement of Inspection-Related Regulation of Fire Protection Systems and Equipment - Focused on the Fire Administration Process - (소방시설 자체점검 관계법령의 개선방안에 대한 연구 - 소방행정프로세서를 중심으로 -)

  • Lee, Jong Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.188-193
    • /
    • 2019
  • In the past, the risk of fire and the rate of fire occurrence has increased gradually as the quality of life improved due to rapid economic growth, and the government enacted Fire Prevention Act. The existing inspection method was revised considering the rapid increase in the number of fire-fighting objects(hereinafter referred to as specific fire-fighting objects) that require the installation of fire-fighting facilities, and has been applied to this day. On the other hand, unlike the rapid increase in specific fire-fighting objects and the development of fire prevention technologies, the scope of work and inspections by unsuitable inspectors caused a large fire accident, which required improvement of the related laws. This study evaluated, the Act on the relationship of firefighting facilities, which had been implemented previously to identify fire victims, save lives, secure independence of fire inspection agencies, and ensure the accuracy of fire prevention actions.

A Study on the Constructions of Fire Events Probabilistic Safety Assessment Model for Nuclear Power Plants (원자력발전소의 화재사건 확률론적안전성평가 모델 구축에 관한 연구)

  • Kang, Dae Il;Kim, Kilyoo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.187-194
    • /
    • 2016
  • A single fire event within a fire area can cause multiple initiating events considered in internal events probabilistic safety assessment (PSA). For an example, a fire event in turbine building fire area can cause a loss of the main feed-water and loss of off-site power initiating events. This fire initiating event could result in special plant responses beyond the scope of the internal events PSA model. One approach to address a fire initiating event is to develop a specific fire event tree. However, the development of a specific fire event tree is difficult since the number of fire event trees may be several hundreds or more. Thus, internal fire events PSA model has been generally constructed by modifications of the pre-developed internal events PSA model. New accident sequence logics not covered in the internal events PSA model are separately developed to incorporate them into the fire PSA model. Recently, many fire PSA models have fire induced initiating event fault trees not shown in an internal event PSA model. Up to now, there has been no analytical comparative study on the constructions of fire events PSA model using internal events PSA model with and without fault trees of initiating events. In this study, the changing process of internal events PSA model to fire events PSA model is analytically presented and discussed.

A Study on the Safety Management Measures Efficient Chemical Substances (화학물질의 효율적 안전관리 방안에 관한 연구)

  • Choi, Min-Ki;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.37-50
    • /
    • 2013
  • It is not an exaggeration to say that modern chemicals take a leading place in our life, and people live with the chemicals, having a huge impact on their daily life. The chemical industry in South Korea, ranked seventh in the world, is one of the key industries that are forming greater part of Korean economy. The actual state of the chemical industries, however, is that over 14 tons of hazardous chemicals are being discharged annually and threaten people's lives with a lack of knowledge of its potential danger. In this way, not only beneficial to us, some of these substances, All chemicals, but also present a threat fundamentally our living environment to hazards to human health and the environment, accidents such chemicals, unlike accidents general understanding the scale of damage and propagation velocity has a complex very difficult risk profile, that can occur during deployment of an accident type is also very diverse. Is the actual situation of public concern against harmful chemicals management's is amplified by the chemical accident in the wake such accidents, government and corporate and reactive system and management system prior to the chemical accident the need for communication to exchange ideas with each other between residents, providing information is important. Therefore, the government departments and corporations, which manage variety of chemicals, ought to contribute toward a development of national security by rigid control over the Hazardous chemicals.