• Title/Summary/Keyword: fine manipulation

Search Result 28, Processing Time 0.024 seconds

Structural Manipulation of Microwell for Enhancing Analytical Performance of Enzyme Immunoassay

  • Sungsoo Kim;Eunjine Kim;Chungwan Lee;Jaewoong Sull;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.30 no.3
    • /
    • pp.131-136
    • /
    • 2024
  • In this investigation, a novel design for a well-plate structure was created to optimize antigen-antibody reactions. The main objective during the development process was to enhance the internal structure of the well plate and increase the surface area. To improve efficiency, the newly designed well-plate was conical in shape and featured internal protrusions, or fins, which increased the surface area per unit volume by 1.45 times compared to standard plates. The performance of the newly developed well plate was assessed using a sandwich CLEIA system, which demonstrated a detection limit approximately 2.5 times better than that of commercial products. Additionally, the coefficient of variation (CV%) was superior to that of commercial products, with inter-assay CV(%) ≤ 11 and intra-assay CV(%) ≤ 9, compared with inter-assay CV(%) ≤ 15 and intra-assay CV(%) ≤ 10 for commercial products. Furthermore, the newly designed well plate demonstrated higher reaction efficiency, even with smaller sample volumes (25~50 µL) compared to the 50~100 µL typically required by commercial well plates. The incorporation of fine patterns increases the number of active sites available for interaction with the samples, thereby significantly enhancing the reaction sensitivity and overall performance.

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

Acoustic Levitation and Rotation Produced by Ultrasonic Flexural Vibration (초음파 굽힘 진동에 의한 음향 부상 및 회전)

  • Loh, Byoung-Gook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.432-438
    • /
    • 2004
  • Acoustic levitation induced by ultrasonic flexural vibration at 28.4 KHz with a vibration amplitude of 10 micrometers is presented. Levitation of multiple objects along the length of the beam in a gap of 8.3 mm which is the half of acoustic wavelength is experimentally demonstrated. Analytical analysis predicts that levitated objects for the gap of half-the wavelength converges to the center of the gap, which is experimentally verified. It is observed that levitated objects with well-balanced mass distribution are set into rotation due to acoustic streaming. For cylinder-shaped Styrofoam with a diameter of 1.8 mm and a length of 3 mm, measured rotational velocity is 2400 revolution per minute. Applications of standing wave field levitation (SWFL) include manipulation of biological cells and blood constituents in biotechnology, and fine powder in material engineering.

Controlled Synthesis of Single-Walled Carbon Nanotubes

  • Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.2-2
    • /
    • 2011
  • Single-walled carbon nanotubes (SWNTs) have been considered as a promising candidate for nextgeneration electronics due to its extraordinary electrical properties associated with one-dimensional structure. Since diversity in electronic structure depends on geometrical features, the major concern has been focused on obtaining the diameter, chirality, and density controlled SWNTs. Despite huge efforts, the controlled synthesis of SWNTs has not been achieved. There have been various approaches to synthesize controlled SWNTs by preparation of homogeneously sized catalyst because the SWNTs diameter highly depends on catalyst nanoparticles size. In this study, geometrically controlled SWNTs were synthesized using designed catalytic layers: (a) morphologically modified Al2O3 supporting layer (Fe/Al2O3/Si), (b) Mo capping layer (Mo/Fe/Al/Si), and (c) heat-driven diffusion and subsequent evaporation process of Fe catalytic nanoparticles (Al2O3/Fe/Al2O3/Si). These results clearly revealed that (a) the grain diameter and RMS roughness of Al2O3 supporting layer play a key role as a diffusion barrier for obtaining Fe nanoparticles with a uniform and small size, (b) a density and diameter of SWNTs can be simultaneously controlled by adjusting a thickness of Mo capping layer on Fe catalytic layer, and (c) SWNTs diameter was successfully controlled within a few A scale even with its fine distribution. This precise control results in bandgap manipulation of the semiconducting SWNTs, determined by direct comparison of Raman spectra and theory of extended tight binding Kataura plot. We suggest that these results provide a simple and possible way for the direct growth of diameter, density, and bandgap controlled SWNTs by precise controlling the formation of catalytic films, which will be in demand for future electronic applications.

  • PDF

A Study on the Color of Neo-Impressionism on the Fabric Pattern of Modern Fashion - From 1987 To 1991- (현대의상 직물 문양에 조명된 신인상주의 색채 표현에 관한 연구 -1987년부터 1991년까지-)

  • Lee Hyo Jin;Jung Heung Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.209-221
    • /
    • 1992
  • A standpoint art's style, present-day Western dress was establishing a systematic, theoritical value in sphere of fine art's meaning & it's expression on the modern fashion. For this reason, I selected Impressionism (a broad senes: be included Impressionism, Neo-Impressionism, Post-Impressionism) that was designated 'the revolution of color'. In the previous paper, 1 already discussed about the modern fashion under the influence of the color of Impressionism, from this study, Neo-Impressionism's techniques & it's influence on the modern fashion was investigated. The Impressionists had purposely used uneven brushwork & a vivid palette to transmit the intensity & immediacy of nature, whereas the Neo-Impressionists utilized methodically applied dots, a technique commonly described as Pointillism, to achieve their rationalist goal of eliminating the fugitive & the casual in order to seize a more fundamental reality. Of all them, Seurat had already become interested in the posible analogies between science, music & psychology on the on hand & art on the other, and scientist's books & articles offered a wealth of theoretical support. 1'articulary, it was corroborated that effects of sadness, calm, or happiness could be achieved through manipulation of color & design. The conclusions are as follow: 1. Through the modern fashion, a space between pattern & pattern was reflected unstable balances & harmonies, that, Neo-Impressionist emphasized the distinction between outdoor & subject, between elaborately clothed & nude figures, corresponded to modern fashion's pattern. 2. The modern fashion was presented a small border or band within the pattern itself which colors complemented those of the adjacent pictorial surface and mediated between the painted image & its enclosure.

  • PDF

Recent Advances in Cancer Diagnosis: On an Overview of Diagnostic Cytopathologic Modalities and Ancillary Techniques (세포병리학적 기초에 의한 암진단의 발전: 진단방법과 보조기법)

  • Kim, Ki-Tai;Ham, Eui-Keun
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 1996
  • From the concepts of cellular pathology and of exfoliative cytology, as elucidated by Virchow and Papanicolaou respectively in the late 19th and early 20th century, have evolved the primary methods for the diagnosis of cancer today. From Papanicolaou's concept of exfoliative cytology developed fine needle aspiration biopsy in the early 1960's, this has become a major diagnostic procedure and has contributed to a significant reduction in open biopsies and, therefore, to medical cost-effectiveness immunobiochemical techniques provided us with a supplement to cancer diagnosis in the 1980's. The immunoperoxidase method, using monoclonal antibodies, is applied primarily as an ancillary measure to elucidate the nature of cancers The availability of specific monoclonal antibodies has greatly facilitated the identification of cell products or surface markers. For example, antibodies directed against intermediate filaments have proved to be of value in determining the histogenesis oi poorly differentiated neoplasms. Tumor markers may serve as biochemical indicators of the presence of a neoplasm. They can be detected In plasma and other body fluids. Their concentration can be applied as a diagnostic test, for monitoring the clinical course of known cancer, and as a screening measure to detect certain cancers in a population at risk. Flow cytometry is a useful tool for distinguishing several cell characteristics, such as the immunophenotype of leukemia-lymphoma cells, the DNA content of neoplastic cells, and cell proliferation rate. Molecular biologic techniques provided a giant step for the management of cancer patients encompassing diagnosis, prognostic evaluation, and therapy. Nucleic acid hybridization techniques are utilized as Southern, Northern, and dot blots and in situ hybridization. Molecular biology and its techniques may bring a blight new horizon for understanding cancer biology and in designing therapy on the basis of gene manipulation.

  • PDF

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Thyroplasty for the Restoration of a Normal Voice (음성개선을 위한 갑상연골성형술)

  • 김기령;김광문;정명현;이원상;정승규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.1-10
    • /
    • 1982
  • The use of phonosurgery in the recent development of laryngomicrosurgery has enabled the restoration of a normal voice in respect to functional laryngeal surgery which in Korea in the past limited to simple removal of benign laryngeal tumor such as laryngeal polyp or nodules and cordal injection of $Teflon^{{\circledR}}$ for the treatment of recurrent nerve paralysis under the vision of suspension laryngoscopy. Performance of phonosurgery for the treatment of cord paralysis, mutational dysphonia, vocal cord atrophy, hyperkinetic dysphonia and sulcus vocalis is a happy event in the view point of development of phonosurgery in Korea. In this aspect thyroplasty to change the position and physical characteristics of the cord outside the glottis instead of the direct handling of the vocal cord through direct endoscopy is popular. Among the 4 types of thyroplasty, classified by Insshiki(1974), type I thyroplasty(1ateral compression of vocal cord) and type IV thyroplasty(lengthening of vocal cord) were effective in the treatment of unilateral vocal cord paralysis. Advantages of this operation are the fine adjustment of the degree of lateral compression under local anesthesia according to the phonation of the patient during operation and avoidance of dyspnea and intralaryngeal hemorrhage due to the manipulation outside the internal perichondrium of the thyroid cartilage. We did 7 cases of thyroplasty for the treatment of unilateral vocal cord paralysis in the 7 months from September 1981 to March 1982. Before the operation aerodynamic study, psychoacoustical evaluation, stroboscopy and sound spectrographic analysis were done. Two months after the operation the above procedures were performed again. Results of preoperative and postoperative examination were compared and the following results were obtained. 1) In the aerodynamic study, maximum phonation time increased to 158% of the preoperative value and the phonation quotient and the mean flow rate decreased to 58% and 54% of preoperative values. 2) The degree of hoarseness improved in the psychoacoustical evaluation and the glottic chink during phonation was decreased in the stroboscopic examiantion. 3) In the sound spectrographic analysis, periodicity was much restored and noise distribution decreased especially in the high frequency area.

  • PDF