• Title/Summary/Keyword: filters

Search Result 4,199, Processing Time 0.03 seconds

PI and Fuzzy Logic Controller Based 3-Phase 4-Wire Shunt Active Filters for the Mitigation of Current Harmonics with the Id-Iq Control Strategy

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.914-921
    • /
    • 2011
  • Commencing with incandescent light bulbs, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and their response to problems caused by harmonics. The prevalent difficulties with harmonics are voltage and current waveform distortions. In addition, Electronic equipment like computers, battery chargers, electronic ballasts, variable frequency drives, and switching mode power supplies generate perilous amounts of harmonics. Issues related to harmonics are of a greater concern to engineers and building designers because they do more than just distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality is becoming more and more serious with each passing day. As a result, active power filters (APFs) have gained a lot of attention due to their excellent harmonic compensation. However, the performance of the active filters seems to have contradictions with different control techniques. The main objective of this paper is to analyze shunt active filters with fuzzy and pi controllers. To carry out this analysis, active and reactive current methods ($i_d-i_q$) are considered. Extensive simulations were carried out. The simulations were performed under balance, unbalanced and non sinusoidal conditions. The results validate the dynamic behavior of fuzzy logic controllers over PI controllers.

IIR(SPKF)/FIR(MRHKF Filter) Fusion Filter and Its Performance Analysis (IIR(SPKF)/FIR(MRHKF 필터) 융합 필터 및 성능 분석)

  • Cho, Seong-Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.12
    • /
    • pp.1230-1242
    • /
    • 2007
  • This paper describes an IIR/FIR fusion filter for a nonlinear system, and analyzes the stability of the fusion filter. The fusion filter is applied to INS/GPS integrated system, and the performance is verified by simulation and experiment. In the fusion filter, an IIR-type filter (SPKF) and FIR-type filter (MRHKF filter) are processed independently, then the two filters are merged using the mixing probability calculated using the residuals and residual covariance information of the two filters. The merits of the SPKF and the MRHKF filter are embossed and the demerits of the filters are diminished via the filter fusion. Consequently, the proposed fusion filter has robustness against to model uncertainty, temporary disturbing noise, large initial estimation error, etc. The stability of the fusion filter is verified by showing the closeness of the states of the two sub filters in the mixing/redistribution process and the upper bound of the error covariance matrices. This fusion filter is applied into INS/GPS integrated system, and important factors for filter processing are presented. The performance of the INS/GPS integrated system designed using the fusion filter is verified by simulation under various error environments and is confirmed by experiment.

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

RF Integrated Electromagnetic-Noise Filters Incorporated with Nano-granular Co41Fe38AI13O8 Soft Magnetic Thin Films on Coplanar Transmission Line

  • Sohn, Jae-Cheon;Yamaguchi Masahiro;Lim, Sang-Ho;Han, Suk-Hee
    • Journal of Magnetics
    • /
    • v.10 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • The RF integrated noise filters are fabricated by photolithography. The stack for the electromagnetic noise filters consists of the nano-granular ($Co_{41}Fe_{38}AI_{13}O_8$) soft magnetic film / $SiO_2$ / Cu transmission line / seed layer (Cu/Ti) / $SiO_2$-substrate. A good signal-attenuation feature along with a low signal-reflection feature is observed in the present filters. Especially in the noise filter incorporated with a $Co_{41}Fe_{38}AI_{13}O_8$ magnetic film with lateral dimensions of $2000{\mu}m$ wide, 15 mm long and $1{\mu}m$ thick, the maximum magnitude of signal attenuation reaches -55 dB, and the magnitude of signal reflection is below -10 dB in the overall frequency range. And this level of signal attenuation is much larger than that of a noise filter incorporated with a Fe magnetic film.

An analysis of tunable characteristic for magnetically tunable E-plane waveguide filters (Magnetically Tunable E-평면형 도파관 여파기 Tunable 특성 분석)

  • 이해선;윤상원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.87-97
    • /
    • 1998
  • This paper describes an analysis of tunable characteristic for magnetically tunable E-plane type finline filter on a ferrite substrate. The proposed design is based on using of quarter wavelength transmission line for compensating the negative length transmission line of end K-inverters of E-plane type waveguide filters and the tunable characteristics of designed filters are analyzed. The analysis results of filter and inverter structure loaded with finline on a ferrite substrate are obtained using the edge based finite element method including higher order mode effects. The X-band experimental results for bilateral and unilateral finline magnetically tunable E-plane type waveguide filters agree well with the simulated data.

  • PDF

Protection against Aerosols by particulate Respirators and Fit Performance (방진마스크의 에어졸 방어효과와 밀착정도)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

Double-tuned Filter Design For HVDC System (HVDC System 적용 Double-tuned 필터의 설계 방법 연구)

  • Lee, Hee-Jin;Nam, Tae-Sik;Son, Gum-Tae;Park, Jung-Wook;Chung, Yong-Ho;Lee, Uk-Hwa;Baek, Seung-Taek;Hur, Kyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1232-1241
    • /
    • 2012
  • The ac side current of an high voltage direct current (HVDC) converter is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac system, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac side filters are also employed to compensate network requested reactive power because HVDC converters also consume substantial reactive power. Among different types of filters, double-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of double-tuned filter; equivalent method and parametric method. Using a parametric method, in particular the paper proposes a new design algorithm for a realistic system. Finally, the performance of the design algorithm is evaluated for a 80kV HVDC system in Jeju island with PSCAD/EMTDC program. The results cleary demonstrate the effectiveness of proposed design method in harmonics elimination and steady-state stability.

Multiuser Channel Estimation Using Robust Recursive Filters for CDMA System

  • Kim, Jang-Sub;Shin, Ho-Jin;Shin, Dong-Ryeol
    • Journal of Communications and Networks
    • /
    • v.9 no.3
    • /
    • pp.219-228
    • /
    • 2007
  • In this paper, we present a novel blind adaptive multiuser detector structure and three robust recursive filters to improve the performance in CDMA environments: Sigma point kalman filter (SPKF), particle filter (PF), and Gaussian mixture sigma point particle filter (GMSPPF). Our proposed robust recursive filters have superior performance over a conventional extended Kalman filter (EKF). The proposed multiuser detector algorithms initially use Kalman prediction form to estimated channel parameters, and unknown data symbol be predicted. Second, based on this predicted data symbol, the robust recursive filters (e.g., GMSPPF) is a refined estimation of joint multipaths and time delays. With these estimated multipaths and time delays, data symbol detection is carried out (Kalman correction form). Computer simulations show that the proposed algorithms outperform the conventional blind multiuser detector with the EKF. Also we can see it provides a more viable means for tracking time-varying amplitudes and time delays in CDMA communication systems, compared to that of the EKF for near-far ratio of 20 dB. For this reason, it is believed that the proposed channel estimators can replace well-known filter such as the EKF.

Denoising PIV velocity fields and improving vortex identification using spatial filters (공간 필터를 이용한 PIV 속도장의 잡음 제거 및 와류 식별 개선)

  • Jung, Hyunkyun;Lee, Hoonsang;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.48-57
    • /
    • 2019
  • A straightforward strategy for particle image velocimetry (PIV) interrogation and post-processing has been proposed, aiming at reducing errors and clarifying vortex structures. The interrogation window size should be kept small to reduce bias error and improve spatial resolution. A spatial filter is then applied to the velocity field to reduce random error and clarify flow structure. The performance of three popular spatial filters were assessed: box filter, median filter, and local quadratic polynomial regression filter. In order to quantify random uncertainty, the image matching (IM) method is applied to an experimental dataset of homogeneous and isotropic turbulence (HIT) obtained by 2D-PIV. We statistically analyze the uncertainty propagation through the spatial filters, and verify the reduction in random uncertainty. Moreover, we illustrate that the spatial filters help clarify vortex structures using vortex identification criteria. As a result, PIV random uncertainty was reduced and the vortex structures became clearer by spatial filtering.

Evaluation of Point-Of-Use (POU) Filters Performance in Chemical Mechanical Polishing Slurry Supply System (슬러리 공급 시스템을 이용한 화학적 기계적 연마 공정에서의 POU 필터의 성능 평가)

  • Jang, Sunjae;Kim, Hojoong;Jin, Hongi;Nam, Miyeon;Kulkarni, Atul;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • The chemical mechanical polishing (CMP) process is widely used in semiconductor manufacturing process for planarization of various materials and structures. Point-of-use (POU) filters are used in most of the CMP processes in order to reduce the unwanted micro-scratches which may result in defects. The performance of the POU filter is depends on type and size of the abrasives used during cleaning process. For this reason, there is a need to evaluate POU filters for their filtration efficiency (FE) with different types of abrasives. In this study, we developed filter test system to evaluate the FE of POU using ceria and silica abrasives (slurry). The POU filter is roll type capsule filter with retention size of 0.2 ${\mu}m$. Two POU filters of different make are evaluated for FE. We observed that both POU filters show similar filtration efficiency for silica and ceria slurry. Results reveal that the ceria slurry and the colloidal silica particle are removed not only by mechanical way but also hydrodynamic and electrostatic interaction way.