• Title/Summary/Keyword: filter clogging

Search Result 85, Processing Time 0.025 seconds

Drain Capacity of PVD Filter Considering the Field Condition (현장 토질특성을 고려한 연직배수재 필터의 성능평가)

  • Han, Sung-Su;Jeong, Kyeong-Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • PVD (Prefabricated Vertical drain) consists of filter and core. An effective PVD has two basic filtration functions ; first to retain soil particle ; and second, to allow water to pass from the soil into the PVD core without clogging or blinding. Clogging which reduces the permeability of the geotextile filter jacket is caused by fine particles penetrating into the geotextile filter jacket in relatively low permeability soil conditions. As clogging performance increases gradually, excess pore water flow from soil is resisted and finally consolidation delays. Current soil-geotextile filter system criteria are generally based on relationships between a representative pore size of the geotextile and particle size of the soil. In Korea, PVD geotextile filter system criteria have been applied by only testing AOS (Apparent Opening Size) of filters without evaluating the filtration and clogging performance on soil-geotexile filter systems. Therefore, the filtration tests on soil-geotexile filter systems were conducted in order to evaluate the filtration and clogging performance with 3 kinds of geotextile filters. On these tests, we have applied geotextile filter system criteria on PVD in ${\bigcirc}{\bigcirc}$ sites.

  • PDF

A Study on Clogging and Hydraulic Properties for Drain Filters of Tunnels (터널배수재 필터의 폐색 및 수리적 특성에 관한 연구)

  • 문준석;한봉수;장연수;이두화
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.111-115
    • /
    • 2001
  • Durability of tunnel drains is important, because the accumulation of groundwater around the tunnel due to clogging of filter or reduction of discharge capacity of drain causes reduction of the life time of tunnel linings. In this paper, clogging and discharge capacity of drain and filter of tunnels are evaluated using a gradient ratio test and filter design criteria. The results of the gradient ratio test showed that gradient ratio(GR) is high when fine content is high in the soil samples and equivalent opening size(EOS) of filter materials is small. Measured GR was less than allowable critical gradinet ratio : 3.0, which is the clogging criteria of U.S. Army Corps of Engineers.

  • PDF

Filter Clogging of Leachate Collection and Removal System at Waste Landfill (폐기물 매립지 침출수 집.배수 시스템에서 필터 막힘에 관한 연구)

  • 고재학;이재영;노희정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.77-80
    • /
    • 1999
  • In this study, to evaluate the performance of leachate collection and removal system, the clogging of geotextile filter was tested and simulated for HELP. As a result of clogging test, the all permeability of geotextiles were decreased rapidly in several day. Also, $Ca^{2+}$ and CODcr concentrations were decreased during test. In model simulation for HELP, Daily discharge volume was shown insignificant change with the filter clogging. however, this result may effect on increasing of the hydraulic gradient in waste layer.r.

  • PDF

Evaluation of the Impact of Filter Media Depth on Filtration Performance and Clogging Formation of a Stormwater Sand Filter (강우유출수 모래 필터의 여과기능 및 폐색 현상에 대한 필터 여재 깊이의 영향 평가)

  • Segismundo, Ezequiel Q.;Lee, Byung-Sik;Kim, Lee-Hyung;Koo, Bon-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.36-45
    • /
    • 2016
  • Sand filters are widely used in infiltration systems to manage polluted urban runoff. Clogging, which is mainly caused by the deposition of sediments on the filter media, reduces the filter system's infiltration capacity, which further limits its lifespan and function. The physical, chemical and biological clogging characteristics of sand filter, therefore, need to be known for effective design and maintenance. Physical clogging behavior and variations in the characteristics of sand filters according to different media depths are examined in this paper. The variations were observed from laboratory column infiltration tests conducted in a vertical flow and fluctuating head condition. It can be seen that an increase in filter media depth results in a high sediment removal performance; however, it leads to a shorter lifespan due to clogging. In the choice of filter media depth to be used in field applications, therefore, the purpose of facilities as well as maintenance costs need to be considered. At all filter media depth configurations, premature clogging occurred because sediments of 100~250 μm clogged the top 15% of filter media depth. Thus, scrapping the top 15% of filter media may be suggested as the first operational maintenance process for the infiltration system.

A Study of the Filter Properties of Natural Fiber Drain (천연마섬유 배수재의 필터특성에 관한 연구)

  • 이광민;장연수;김수삼;고경환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.313-319
    • /
    • 1999
  • The properties of natural fiber filter are evaluated using laboratory experiments to find out the possibility of natural fiber drain as a substitute material of plastic board drain Experiments performed for natural fiber filter are effective opening size, permeability and clogging, Three filters were used in the experiment, which are constituted with the filter of different densities encircled with wefts and warps. The results were compared with those for the filter of MD88-80.

  • PDF

An Experimental Study on the Clogging of Sand Filter in a Model Filtration-Pond (천변여과지 모형에서 여재모래의 폐색현상 실험연구)

  • Jeong, Jae-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.681-685
    • /
    • 2013
  • A pilot-scale sand-box experiment was performed in order to investigate the effect of cross-flow velocity on the clogging of the filter sand in a model filtration pond. The clogging phenomenon was observed during the operation with the cross-flow varied in stages in a range of 0~40 cm/sec, and the experimental result was analyzed using a numerical code. Results showed that the cross-flow velocity in this range had no influence on the development of clogging and that clogging occurred mostly on the filter-surface. It was found that while the production rate decreased from $5m^3/m^2-day$ to $3m^3/m^2-day$ the clogging coefficient of the top 50 cm layer increased up to about 30,000 sec, which corresponded to 87% of the clogging coefficient of the total 2.4 m layer. Of the clogging coefficient of the top 50 cm layer, surface clogging constituted 90% while the other 10% was intermediate clogging. It was also found that the surface clogging increased while the intermediate clogging remained constant as the operation continued, and that filtrate turbidity along the filtration depth remained constant in spite of the increase in clogging.

Effect of the Internal Clogging on the Kink Zone of PBD (꺾임이 발생한 연직배수재의 내부 막힘현상)

  • Kim, Rae-Hyun;Hong, Sung-Jin;Kim, Jae-Jeong;Choi, Yong-Min;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.729-736
    • /
    • 2009
  • Several well resistance effects induced by bending, confining stress, temperature, bubbles, and apparent opening size have been considered and researched for the reasonable PBD design. The effect of apparent opening size(AOS), however, was not extensively studied and the clogging effect by AOS was not clearly researched. In this paper, the slurry consolidation test which 4 types of PBD are installed in large slurry consolidometer($H{\times}D$, $2.0m{\times}1.2m$) is performed to investigate the clogging effect by filter's AOS. The results show that the internal clogging is observed all types of PBD, and a quantity of inflowed soil particles are increased at the lower part of PBD and the kink zone. In addition, the internal clogging phenomenon does not relate with the shape and size of PBD. In filter's AOS test, it was easily observed that soil particles bigger than AOS of tested filter passed PBD filter by SEM. This paper demonstrates that the reduction of discharge capability may be accelerated by internal clogging at the kink zone.

  • PDF

Examination of Dust Trapping Mechanism in a Metal Fiber Filter-bed (금속 섬유 필터층을 이용한 미세 분진 집진 성능 관찰)

  • 이경미;조영민
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.361-369
    • /
    • 2004
  • A metal fiber bed has seldom been applied to the practical filtration process despite its excellent mechanical and chemical stability. The filter-bed used in this work was highly porous with open structure, of which apparent porosity was 80 ∼ 90%. Although pressure loss across the filter-bed was very low, separation efficiency was found to be quite high. This paper focuses on the basic filtration mechanisms of a metal filter-bed and a thin ceramic filter from fly ash for reference. The experimental parameters were face velocity, dust loading and porosity of filter-bed. Pressure drop increased with increasing face velocity and dust feeding load for both filters. It also showed that dust particles deposited in the deep flow path, finally resulting in clogging the pore channels. It thereby indicates that the dominating mechanism of the metal filter-bed would be depth filtration. Meanwhile, the thin fly ash composite filters trapped the aerated dust mainly on the surface of the filter medium, so that the instantaneously formed dust layer might cause a steep increase of pressure drop across the filtration system.

Clogging Phenomenon and Drainage Capacity of Tunnel Filters (터널필터재의 폐색현상과 배수성능 평가)

  • 이인모;유승헌;박광준;이석원;김홍택
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.3-18
    • /
    • 1999
  • The geotextile filter, which is installed between the ground and the lining and used as a tunnel drainage system, should have sufficient groundwater drainage capacity so that water pressure does not act on the lining. The clogging may have a serious effect on the long term behaviour of geotextile filters. Two typical weathered residual soils in Korea, Shinnae-dong soil and Poi-dong soil, were chosen to investigate the in-plane flow characteristics of the soils with varying degree of compressive stresses applied on the geotextiles and with various conditions of hydraulic gradient. The Shinnae-dong soil is a relatively coarse material classified as'SW-SM'; on the other hand, the Poi-dong soil is much finer and is classified as'SC'. Based on the comparison of the $O_{95}$ of geotextile to the $D_{15}$ of residual soils, existing clogging criteria were reviewed, and a tentative clogging criterion for the in-plane flow of the residual soil through filters was proposed. The Shinnae-dong soil showed noticeable clogging phenomenon, while the clogging of the Poi-dong soil was not so serious. The Poi-dong soil seemed to be hindered in particle transport by its cohesiveness.

  • PDF