Abstract
The geotextile filter, which is installed between the ground and the lining and used as a tunnel drainage system, should have sufficient groundwater drainage capacity so that water pressure does not act on the lining. The clogging may have a serious effect on the long term behaviour of geotextile filters. Two typical weathered residual soils in Korea, Shinnae-dong soil and Poi-dong soil, were chosen to investigate the in-plane flow characteristics of the soils with varying degree of compressive stresses applied on the geotextiles and with various conditions of hydraulic gradient. The Shinnae-dong soil is a relatively coarse material classified as'SW-SM'; on the other hand, the Poi-dong soil is much finer and is classified as'SC'. Based on the comparison of the $O_{95}$ of geotextile to the $D_{15}$ of residual soils, existing clogging criteria were reviewed, and a tentative clogging criterion for the in-plane flow of the residual soil through filters was proposed. The Shinnae-dong soil showed noticeable clogging phenomenon, while the clogging of the Poi-dong soil was not so serious. The Poi-dong soil seemed to be hindered in particle transport by its cohesiveness.
터널의 배수재로 이용되는 지오텍스타일 필터는, 터널 내로 유입되는 지하수를 충분히 배수시키어 터널 라이닝에 수압이 작용되지 않도록 해야 한다. 그러나, 지오텍스타일의 막힘현상으로 인하여 필터재의 통수 능력이 우선적으로 감소하게 되고 막힘현상은 이를 더욱 심각하게 만든다. 본 연구에서는 서울시의 신내동 과 포이동에서 채취한 시료에 대하여 터널 필터재의 평면흐름을 모사하여 폐색현상을 고찰하였다. 신내동 시료는 SW-SM으로 분류되는 사질토에 가까운 시료이며, 반면에 포이동 시료는 SC로 분류되고 점성이 강한 흙이다. 필터재의 이론적인 간극분포곡선과 $O_{95}$로부터 본 실험결과를 근거로 폐색방지기준을 설정하였다. 포이동 시료에 비하여 신내동 시료가 더 뚜렷한 폐색경향을 나타냄을 알 수 있었으며, 이는 포이동 시료에 비하여 점성이 없어 잔입자가 쉽게 이탈되고 필터재에 쌓이는 원인으로 판단되었다.