• Title/Summary/Keyword: filter(normal filter)

Search Result 353, Processing Time 0.024 seconds

Size-Reduction of Frequency Mixers Using Artificial Dielectric Substrate (임의유전체 기판을 이용한 주파수 혼합기의 소형화)

  • Kwon, Kyunghoon;Lim, Jongsik;Jeong, Yongchae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.657-662
    • /
    • 2013
  • A size-reduced high frequency mixer designed by adopting artificial dielectric substrate is described in this work. The artificial dielectric substrate is composed by stacking the lower substrate in which a lot of metalized via-holes exist, and upper substrate on which microstrip lines are realized. The effective dielectric constant increases due to the inserted lots of via-holes, and this may be applied to size-reduction of high frequency circuits. In this work, in order to present an application example of size-reduction for active high frequency circuits using the artificial dielectric substrate, a 8GHz single gate mixer is miniaturized and measured. It is described that the basic circuit elements for mixers such as hybrid, low pass filter, and matching networks can be replaced by the artificial dielectric substrate for size-reduction. The final mixer has 55% of size compared to the normal one. The measured average conversion gain is around 3dB which is almost similar result as the normal circuit.

ROENTGENOGRAPHIC STUDY ON MAXILLOFACIAL SOFT TISSUE IN THE MIXED DENTITION (혼합치열기에 있어서 악안면연조직에 관한 X-선학적 연구)

  • Lee Jae Hie
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.19-26
    • /
    • 1977
  • The purpose of this study was to obtain the cephalometric maxillofacial soft tissue measurements, and to define the differences that exist between males and females on the soft tissue profile who had normal occlusion in mixed dentitions. For the object of this study, cephalometric radiographs were obtained from the centric occlusion with the relaxed lip position. Copper filter was designed to obtain both hard and soft tissue structure on the same film. The subjects consist of 100 males and 100 females from 8 to 12.4 years with the normal occlusion and acceptable profiles. The author measured facial depth, vertical height from the tissue profiles in the mixed dentitions. The significant test compare males with females. The following results were obtained from the study 1. In facial convexity, much more larger females than that of males. 2. Inclination of the lip posture were more larger in maxilla (male) and in females more larger in the mandible. 3. The thickness of soft tissue were thicker in males, the height of nose were more prominent in females. 4. There were no significant differences in both sexes.

  • PDF

A Study on the Development of R-R Interval Analyzer using Microcomputer (1) (Microcomputer를 이용한 R-R Interval Analyzer 개발에 관한 연구 (1))

  • Lee, Joon-Ha;Choi, Soo-Bong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1985
  • The R-R interval analyzer was developed to measure the autonomic nervous system function using microcomputer. The system based on 8 bit microcomputer including bandpass filter, R-wave detector and clock generator in order to obtain the mean value, standard deviation, total time, CV value, maximum value and minimum value in the specific view point of R-R interval variation. The pattern of R-R interval change after resting, voluntary standing and deep breathing can be analysed in normal subjects and diabetics with autonomic nervous dysfunction. The amplitude of the R-R interval variation showed sensitive pattern for normal subjects at resting, standing and deep breathing. On the contrary, the periodicities of amplitude for abnormal subjects with autonomic nervous dysfunction showed dull pattern. It was suggested that R-R interval analyzer is a good detection method for dysfunction of autonomic nervous system.

  • PDF

Dual-Encoded Features from Both Spatial and Curvelet Domains for Image Smoke Recognition

  • Yuan, Feiniu;Tang, Tiantian;Xia, Xue;Shi, Jinting;Li, Shuying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.2078-2093
    • /
    • 2019
  • Visual smoke recognition is a challenging task due to large variations in shape, texture and color of smoke. To improve performance, we propose a novel smoke recognition method by combining dual-encoded features that are extracted from both spatial and Curvelet domains. A Curvelet transform is used to filter an image to generate fifty sub-images of Curvelet coefficients. Then we extract Local Binary Pattern (LBP) maps from these coefficient maps and aggregate histograms of these LBP maps to produce a histogram map. Afterwards, we encode the histogram map again to generate Dual-encoded Local Binary Patterns (Dual-LBP). Histograms of Dual-LBPs from Curvelet domain and Completed Local Binary Patterns (CLBP) from spatial domain are concatenated to form the feature for smoke recognition. Finally, we adopt Gaussian Kernel Optimization (GKO) algorithm to search the optimal kernel parameters of Support Vector Machine (SVM) for further improvement of classification accuracy. Experimental results demonstrate that our method can extract effective and reasonable features of smoke images, and achieve good classification accuracy.

Space-Time Quantization and Motion-Aligned Reconstruction for Block-Based Compressive Video Sensing

  • Li, Ran;Liu, Hongbing;He, Wei;Ma, Xingpo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.321-340
    • /
    • 2016
  • The Compressive Video Sensing (CVS) is a useful technology for wireless systems requiring simple encoders but handling more complex decoders, and its rate-distortion performance is highly affected by the quantization of measurements and reconstruction of video frame, which motivates us to presents the Space-Time Quantization (ST-Q) and Motion-Aligned Reconstruction (MA-R) in this paper to both improve the performance of CVS system. The ST-Q removes the space-time redundancy in the measurement vector to reduce the amount of bits required to encode the video frame, and it also guarantees a low quantization error due to the fact that the high frequency of small values close to zero in the predictive residuals limits the intensity of quantizing noise. The MA-R constructs the Multi-Hypothesis (MH) matrix by selecting the temporal neighbors along the motion trajectory of current to-be-reconstructed block to improve the accuracy of prediction, and besides it reduces the computational complexity of motion estimation by the extraction of static area and 3-D Recursive Search (3DRS). Extensive experiments validate that the significant improvements is achieved by ST-Q in the rate-distortion as compared with the existing quantization methods, and the MA-R improves both the objective and the subjective quality of the reconstructed video frame. Combined with ST-Q and MA-R, the CVS system obtains a significant rate-distortion performance gain when compared with the existing CS-based video codecs.

A Study on a Algorithm of Gait Analysis and Step Count with Pressure Sensors (보행수 측정 및 보행패턴 분류 알고리즘)

  • Do, Ju-pyo;Choi, Dae-yeong;Kim, Dong-jun;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1810-1814
    • /
    • 2017
  • This paper develops an approach to the algorithm of Gait pattern Analysis and step measurement with Multi-Pressure Sensors. The process of gait consists of 8 steps including stance and swing phase. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. normal gait proceed from heel, forefoot and big toe over time. While normal gait proceeds, values of heel, forefoot and big toe can be changed over time. So Each values of pressure sensors over time could discriminate whether it is normal or abnormal gait. Measuring Device consists of non-inverting amplifiers and low pass filter. Through timetable of values, normal gait pattern can be analyzed, because of supported weight of foot. Also, the peak value of pressure can judge whether it is walking or running. While people are running, insole of shoes is floating in the air on moment. Using this algorithm, gait analysis and step count can be measured.

Development and Validation of a Machine Learning-based Differential Diagnosis Model for Patients with Mild Cognitive Impairment using Resting-State Quantitative EEG (안정 상태에서의 정량 뇌파를 이용한 기계학습 기반의 경도인지장애 환자의 감별 진단 모델 개발 및 검증)

  • Moon, Kiwook;Lim, Seungeui;Kim, Jinuk;Ha, Sang-Won;Lee, Kiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.185-192
    • /
    • 2022
  • Early detection of mild cognitive impairment can help prevent the progression of dementia. The purpose of this study was to design and validate a machine learning model that automatically differential diagnosed patients with mild cognitive impairment and identified cognitive decline characteristics compared to a control group with normal cognition using resting-state quantitative electroencephalogram (qEEG) with eyes closed. In the first step, a rectified signal was obtained through a preprocessing process that receives a quantitative EEG signal as an input and removes noise through a filter and independent component analysis (ICA). Frequency analysis and non-linear features were extracted from the rectified signal, and the 3067 extracted features were used as input of a linear support vector machine (SVM), a representative algorithm among machine learning algorithms, and classified into mild cognitive impairment patients and normal cognitive adults. As a result of classification analysis of 58 normal cognitive group and 80 patients in mild cognitive impairment, the accuracy of SVM was 86.2%. In patients with mild cognitive impairment, alpha band power was decreased in the frontal lobe, and high beta band power was increased in the frontal lobe compared to the normal cognitive group. Also, the gamma band power of the occipital-parietal lobe was decreased in mild cognitive impairment. These results represented that quantitative EEG can be used as a meaningful biomarker to discriminate cognitive decline.

Evaluation of flux stabilisation using Bio-UF membrane filter on KZN Rivers, South Africa

  • Thoola, Maipato I.;Rathilal, Sudesh;Pillay, Lingam V.
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.313-325
    • /
    • 2016
  • South Africa recognises piped water as the main source of safe drinking water supply. Remote areas do not have access to this resource and they rely solely on surface water for survival, which exposes them to waterborne diseases. Interim point of use solutions are not practiced due to their laboriousness and alteration of the taste. Bio-ultra low pressure driven membrane system has been noted to be able to produce stable fluxes after one week of operation; however, there is limited literature on South African waters. This study was conducted on three rivers namely; Umgeni, Umbilo and Tugela. Three laboratory systems were setup to evaluate the performance of the technology in terms of producing stable fluxes and water that is compliant with the WHO 2008 drinking water guideline with regards to turbidity, total coliforms and E.coli. The obtained flux rate trends were similar to those noted in literature where they are referred to as stable fluxes. However, when further comparing the obtained fluxes to the normal dead-end filtration curve, it was noted that both the Umbilo and Tugela Rivers responded similarly to a normal dead-end filtration curve. The Umgeni River was noted to produce flux rates which were higher than those obtainable under normal dead-end. It can be concluded that there was no stabilisation of flux noted. However, feed water with low E.coli and turbidity concentrations enhances the flux rates. The technology was noted to produce water of less than 1 NTU and 100% removal efficiency for E.coli and total coliforms.

Association between taste perception, nutrient intake, and mental health in young Japanese women

  • Okayama, Tomoko;Watanabe, Hiroko
    • Nutrition Research and Practice
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: Taste perception is influenced by both nutritional factors and psychological factors. This study was undertaken to measure the 4 basic taste perceptions, nutrient intake, and mental health, and to examine the factors that affect insensitive taste perception in young Japanese women. SUBJECTS/METHODS: Young women in their late teens and twenties were enrolled as subjects. Taste perception was measured by applying the filter-paper disc method over areas of the chorda tympani nerve. Nutritional status was evaluated using brief, self-administered diet history questionnaires. The index of nutritional status was based on the 2015 Japanese dietary reference intakes. Mental health was assessed using the Japanese translation of the Profile of Mood States short version. This study was approved by the ethical committee at Osaka University. RESULTS: The normal taste perception group (four basic tastes [sweet, salty, sour, and bitter] identified as normal taste perception) comprised 55.4% of the subjects, while the abnormal taste perception group (more than 1 abnormal taste perception was perceived, regardless of flavor) comprised 44.6% of the subjects. There were no significant differences in nutrient intake (except manganese) and mental health between the normal and abnormal taste perception groups. Subjects who took 5 mg to less than 7.1 mg zinc per day were at significantly decreased risk of insensitive taste perception compared to subjects who consumed less than 5 mg zinc per day [Regression coefficient 0.831, 95% confidence interval 0.694-0.996]. CONCLUSION: The present results suggest that insensitive taste perception could be associated with zinc deficiency in young women in their late teens and twenties.

Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method

  • Pamela Sung;Jeong Min Lee;Ijin Joo;Sanghyup Lee;Tae-Hyung Kim;Balaji Ganeshan
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.558-568
    • /
    • 2019
  • Objective: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. Materials and Methods: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE4), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). Results: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. Conclusion: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.