Development of a Computer Program for Thermal Sizing of a Copper Bonded Steam Generator (구리밀봉 증기발생기의 열적크기 계산을 위한 프로그램 개발)

  • 김의광;김연식;어재혁;김성오;백병준
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • A one-dimensional thermal-hydraulic analysis computer program is developed for thermal sizing of a copper bonded steam generator. It is assumed that the conduction heat transfer of copper region between the hot side and the cold side tube is one-dimensional and its thermal resistance is derived as a function of a tube pitch. The flow regions of the water/steam side are divided into four regions: subcooled, saturated, film boiling, and super-heated. The number of tube selected ranges from 250 to 3500 and the pitch to tube diameter (P/D) ratios are 1.4, 1.6 and 1.8 for the parametric study calculation. The calculation results showed that when the number of tube was 2500, the length of the heating tube was about 12 m and the outside diameter of the steam generator was about 3 m. If the P/D ratio increases, the thermal resistance of copper component also increases, however the length of the heating tube is not so much increased.

Study on Validity of 1-D Spherical Model on Aqua-plasma Power Estimation With Electrode Structure

  • Yun, Seong-Yeong;Jang, Yun-Chang;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.74-74
    • /
    • 2010
  • The aqua-plasma is the non-thermal plasma in electrical conductive electrolyte by generates the vapor film layer on the immersed metal electrode surface. This plasma can generate the hydroxyl radical by dissociate the water molecule with the plasma electron. To develop the plasma discharge device for high efficiency in the hydroxyl radical generation, proper model for estimation of plasma power is necessary. In this work, the 1-D spherical model was developed, considering temperature dependence material constants. The relation between the plasma power and hydroxyl generation was also studied by the comparison between the optical emission intensity from the hydroxyl radical using monochromator and estimated plasma power. First, the thickness of vapor layer thickness was estimated using the Navier-Stokes fluid equation in order to calculate the discharge E-field inside vapor layer. Using the E-field magnitude and power balance on the plasma generation, it was possible to estimate the plasma power. The plasma power was assumed to uniformly fill the vapor layer and the temperature of vapor layer was fixed in the boiling temperature of electrolyte, 375K. In the experiment, the aqua-plasma was discharged in the saline by applied the voltage on the bipolar electrode. The range of applied voltage was 234 to 280V-rms in the frequency of 380 kHz. Two type electrodes were produced with two ${\Phi}0.2$ tungsten. The plasma power was estimated from the V-I signal from the two high voltage probes and current probe. The estimated plasma power agreed with the profile of emission intensity when the plasma discharged between the metal electrode and vapor layer surface. However, when the plasma discharged between the metal electrodes, the increasing rate of emission intensity was lower than the increase of plasma power. It implies that the surface reaction is more sufficient rather than the volume reaction in the radical generation, due to the high density of water molecule in the liquid.

  • PDF

Critical Heat Flux in Uniformly Heated Vertical Annulus Under a Wide Range of Pressures 0.57 to 15.0 MPa

  • Chun, Se-Young;Chung, Heung-June;Hong, Sung-Deok;Yang, Sun-Kyu;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.128-141
    • /
    • 2000
  • The critical heat flux (CHF)experiments have been carried out in a wide range of pressures for an internally heated vertical annulus. The experimental conditions covered ranges of pressures from 0.57 to 15.01 MPa, mass fluxes of 0 kg/$m^2$s and from 200 to 650 kg/$m^2$s, and inlet subcoolings from 85 to 413 kJ/kg. The characteristics of the present data and the effect of pressure on CHF are discussed. Most of the CHFs were identified to dryout of the liquid film in the annular or annular-mist flow. For the mass flux of 200 kg/$m^2$s, there were the indications that the CHF occurred at the transition from annular to annular-mist How in the pressure range of 3~10 MPa. For the mass fluxes of 550 and 650 kg/$m^2$s, the CHFs had a maximum value at a pressure of 2~3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those on the CHF with net water upward flow.

  • PDF

고온 물에서 304 와 600 합금의 입계응력부식균열(IGSCC)의 상이성과 유사성

  • 권혁상;김수정
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.22-22
    • /
    • 1998
  • 304 는 BWR(boiling water reactor)의 reactor 구조용 재료로 사용되고 있고, 합금 600 은 PWR(pressurized water reator) 의 증기 발생기 세관으로 쓰이고 있으며 모두 약 $280{\;}^{\circ}C$ 이상 의 원자로 냉각수에 노출되어 있다. 원자로 냉각수 분위기에서 두 합금의 공통적인 특정은 입계응력부식균열(IGSCC)에 민감한것과 IGSCC가 예민화(sensitization)와 관련이 있는 것이 다. 두 합금에서 일어나는 IGSCC는 원자력발전소의 부식피해중 가장 빈도가 높고 발생시 방사능 누출로 인하여 원전의 신뢰성을 저하시키고, 가동중단으로 인한 경제적 손실을 초 래하여 지난 20 년 동안 가장 심도있게 연구된 주제다. 304 은 크롬 탄화물의 업계 석출로 언하여 예민화된경우 IGSCC 에 민감한 반면 600 은 예민화된 경우 뿐만 아니라 용체화처리된 상태에서도 IGSCC에 민감하다. 오히려 600은 용 체화처리 후 700 C에서 15~20시간 시효처리를 하여 크롬탄화물을 업계에 석출 시커었을 때 IGSCC 저항성이 향상된다. 두 합금의 IGSCC 특정 중 큰 차이는 304는 임계균열전위 ( (critical cracking potential) 이 존재하여 부식전위(corrosion potential) 가 엄계균열전위보다 낮 은 경우 IGSCC 가 일어나지 않지만 그 반대인 경우 IGSCC 에 민감하게된다. 반면에 600 은 뚜렷한 임계균열전위가 존재하지 않고 양극 분극(anodic polarization) 뿐만 아니라 음극분극 시에도 IGSCC 가 일어난다. 이련 이유로 600의 IGSCC 가구로 피막파괴-양극용해(film rupture-anodic dissolution)외에 수소취성(hydrogen embrittlement)기구도 제안되고 었다. 원전의 냉각수는 고 순도의 물이지만 수 처리 과정과 웅축기 배관의 누수로 인한 산소, $Cu^{2+},{\;}S_xO_6{\;}^{2-}(x=3~6)$ 등이 유입되어 오염되는데 이려한 오염물질들이 수 ppm정도 소량 포함된 경우 응 력부식민감도는 상당히 증가된다. 산성분위기 흑은 산소, $Cu^{2+}$, 등이 소량 포합된 산화성 분위기 그리고 sufur oxyanion 에 오염된 고온의 물에서 600 의 IGSCC 민감도는 예민화도가 증가할 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.

  • PDF

Processing and Property of Olive Flounder Paralichthys olivaceus Terrine (넙치(Paralichthys olivaceus) Terrine 제품의 제조 및 품질특성)

  • YOON, Moon-Joo;LEE, Jae-Dong;PARK, Si-Young;KWON, Soon-Jae;PARK, Jin-Hyo;KANG, Kyung-Hun;CHOI, Jong-Duck;JOO, Jong-Chan;KIM, Jeong-Gyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.4
    • /
    • pp.1084-1091
    • /
    • 2015
  • Aquaculture of olive flounder started in the middle of 1980's and now farming has been taken place in many places along the coastal line in Korea. The taste of olive flounder has a good chewy texture because of high collagen content, low fat content, so it is popular for sliced raw fish. Olive flounder is popular among Koreans but the consumption pattern is uniformly so as to be used as sliced raw fish but not other ways. So, now there needs to develop high valued-processed food using olive flounder. This study was set to investigate the processing of terrine by using olive flounder, in which terrine is French style meat loaf that is well favored around the world. In this study, terrine was prepared by chopping olive flounder meat with 39 g egg white and 10 mL fresh cream (per 50 g fillet) and then seasoned with 5 mL lemon juice, 5 mL brandy, 0.05 g salt and 0.05 g pepper. The 25 g of dough was placed on a vinyl wrap, put with 2 g cheese, and layered an another 25 g dough, and then rolled up and wrapped by aluminium foil. Two different cooking methods were used for terrine processing in this study. Terrine-1 was cooked by vacuum sealed in polyethylene film ($20{\times}30{\times}0.05mm$) after boiling for 5 min and stored at $-20^{\circ}C$ for 7 days. Terrine-2 was prepared by vacuum sealed in polyethylene film ($20{\times}30{\times}0.05mm$) and stored at $-20^{\circ}C$ for 7 days. After 7 days, Terrine-1 was thawed and then heated up in microwave for 2 min (Sample-1), while Terrine-2 was thawed and then boiled in water for 5 min (Sample-2). Viable bacterial count, chemical composition, pH, salinity, hardness, TBA, free amino acid content, and sensory evaluation were measured for both Sample-1 and Sample-2. Especially, the scores of sensory evaluation of Sample-2 is slightly higher than that of Sample-1. On the other hand, there were no significant differences on color, odor, taste, texture, and overall acceptance between Sample-1 and Sample-2.

Investigation of Solvent Effect on the Electrical Properties of Triisopropylsilylethynyl(TIPS) Pentacene Organic Thin-film Transistors (용제에 따른 TIPS(triisopropylsilyl) Pentacene을 이용한 유기박막 트렌지스터의 전기적 특성에 관한 연구)

  • Kim, K.S.;Kim, Y.H.;Han, J.-In;Choi, K.N.;Kwak, S.K.;Kim, D.S.;Chung, K.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.435-441
    • /
    • 2008
  • In this paper, we investigated the electrical properties of triisopropylsilyl (TIPS) pentacene organic thin-film transistor (OTFT) depending on solvent type. We spin coated TIPS pentacene by using chlorobenzene, p-xylene, chloroform, and toluene as solvents. Fabricated OTFT with chlorobenzene shows field-effect mobility of $1.0{\times}10^{-2}cm^2/V{\cdot}s$, on/off ratio of $4.3{\times}10^3$ and threshold voltage of 5.5 V. In contrast, with chloroform, the mobility is $5.8{\times}10^{-7}cm^2/V{\cdot}s$, on/off ratio of $1.1{\times}10^2$ and threshold voltage of 1.7 V. Moreover we measured the grain size of each TIPS pentacene solvent by atomic force microscopy (AFM). From these results, it can be concluded that a solvent with higher boiling point results in better electrical characteristics due to large grain size and high crystallinity of TIPS pentacene layer. In this paper TIPS pentacene with chlorobenzene shows the best electrical properties.

Quality Stability of Instant Powdered Soup using Canned Oyster Processing Waste Water (굴통조림 부산물 유래 인스턴트 분말 수프의 품질안정성)

  • KIM Jin-Soo;Heu Min-Soo;HEU Min-Soo;CHO Moon-Lae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.4
    • /
    • pp.389-393
    • /
    • 2001
  • For an effective utilization, quality stability of instant powdered oyster soup made of canned oyster processing waste water (IPSW) was determined. Instant powdered soup from oyster hot-water extracts (IPSE) was also prepared by mixing hot-water extract powder (15 g) with table salt (5 g), cream powder (19 g), milk replacer (12 g), wheat flour (20 g), corn flour (15 g), starch (5 g), glucose (7.5 g) and onion powder (1.5 g). In preparing IPSW, mixed powder from wash water and boiling liquid waste, instead of powder from hot-water extracts and table salt, was added (powder from boiling liquid waste: powder from wash water= 12: 8) and other additives were added in proportion to those in the IPSE. The moisture content, water activity, peroxide value and fatty acid composition showed little changes during storage of the IPSW. The pH, volatile basic nitrogen content and brown pigment formation increased slightly, while white index decreased slightly during storage of IPSW. No significant difference was observed in the changes of food component during storage between IPSW and IPSE. According to a sensory evaluation, the change in quality of IPSW was negligible during 12 months of storage. from the results of the chemical experiment and sensory evaluation, IPSW packed with laminated film bag (OPP, $20{\mu}m/PE,\;20{\mu}m/paper,\;45g/m^3/PE,\;20{\mu}\;m/Al,\;7{\mu}\;m/PE,\;20{\mu}m$) was revealed to be preserved in good quality during 12 months of storage.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Optical and Electrical Properties with Various Post-Heating Temperatures in the Al-Doped ZnO Thin Films by Sol-Gel Process (졸-겔법에 의해 제조된 Al-Doped ZnO 박막의 후열처리 온도에 따른 전기 및 광학적 특성)

  • Ko, Seok-Bae;Choi, Moon-Sun;Ko, Hyungduk;Lee, Chung-Sun;Tai, Weon-Pil;Suh, Su-Jeong;Kim, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.742-748
    • /
    • 2004
  • Isopropanol of low boiling point was used as a solvent to prepare Al-doped ZnO(AZO) thin films. A homogeneous and stable sol was made from Zn acetate a solute whose mole concentration was 0.7mol/$\iota$ and Al chloride as a dopant. Al-doped ZnO thin films were prepared by sol-gel method as a function of post-heating temperature from 500 to $700^{\circ}C$ and the optical and electrical properties were investigated. The c-axis orientation along (002) plane was enhanced with the increasing of post-heating temperature and the surface morphology of the films showed a homogeneous and nano-sized microstructure. The optical transmittance of the films post-heated below $650^{\circ}C$ was over $86\%$, but decreased at $700^{\circ}C$. The electrical resistivity of the thin films decreased from 73 to 22 $\Omega$-cm as the post-heating temperature increased up to $650^{\circ}C$, but increased greatly to 580 $\Omega$-cm at $700^{\circ}C$. XPS analysis indicated that the deterioration of electrical and optical properties was attributed to the precipitation of $Al_2O_3$ phase on the surface of AZO thin film. This result suggests that the optimum post-heating temperature to improve electrical and optical properties is $600^{\circ}C$.