• Title/Summary/Keyword: film Scanner

Search Result 69, Processing Time 0.03 seconds

DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask (Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구)

  • Sohn, Hyonkee;Park, Jong-Sig;Jeong, Su-Jeong;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.16 no.3
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

A Study on Color Difference Discrimination for PVC Deco-Film using Entry-Level Digital Device (보급형 디지털 장비를 이용한 Deco-Film용 PVC의 색차판별에 대한 연구)

  • Im, Hoyoun;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • Though digital imaging devices such as smart phones, digital cameras and office scanners have improved significantly over the past years, they are seldom used for industrial application. This may be attributable to high level of quality and performance requirement for industrial application, but there lacks a test or an objective evaluation whether the upgraded performance of entry-level device is sufficiently enough to replace existing industrial equipments or not. If there exists an industrial application area where the applicability of entry-level equipment is proved by some objective tests, then companies will be able to reduce investment on expensive industrial equipment. In this study, applicability of entry-level digital devices for color difference discrimination of PVC (Polyvinyl chloride) color sheet is tested. By testing smart phone, digital camera, and office scanner for color difference discrimination, authors have found that office scanner shows consistent result with less measurement error. Additional experiment on comparing office scanner with industrial spectrophotometer has confirmed that there exists high correlation between the two devices' results. Based on this result, office scanner may be applicable to discriminate the color difference of PVC sheet instead of expensive industrial spectrophotometer if proper management criteria are established.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

Assessment of the Measurement Method of the Bone Mineral Density on Cu-Equivalent Image (구리당량 영상작성에 의한 골밀도계측방법의 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.101-108
    • /
    • 2000
  • Purpose : The effects of step numbers of copper wedge and exposure on the coefficient of determination (r²) of the conversion equation to Cu-equivalent image and on the Cu-equivalent value (mmCu) and it's coefficient of variation measured at each copper step and the mandibular premolar area were evaluated. Method: Digital image analyzing system consisted of scanner, personal computer, and a stepwedge with 10 steps of 0.03 mm copper in thickness as reference material was prepared for quantitative assessment of the bone mineral density. NIH image program was used for analyzing images. Results : The film having moderately high film density showed the discrepancy between the real thickness and the measured Cu-equivalent value of each copper step. The Cu-equivalent image was dependent on the determinational coefficient of the conversion equation than the coefficient of variance of the measured value. Conclusion : Obtaining conversion equation with high coefficient of determination and proper film exposure are supposed to be neccessary for quantitative assessment of bone density. Multiple steps in the range of the corresponding copper thickness to the bone density of the area to be measured should be prepared.

  • PDF

Femtosecond laser pattering of ITO film on flexible substrate (펨토초 레이저를 이용한 플렉시블 ITO 패터닝 연구)

  • Sohn, Ik-Bu;Kim, Young-Seop;Noh, Young-Chul
    • Laser Solutions
    • /
    • v.13 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Indium tin oxide (ITO) provides high electrical conductivity and transparency in the visible and near IR (infrared) wavelengths. Thus, it is widely used as a transparent electrode for the fabrication of liquid crystal displays (LCDs) and organic light emitting diode displays (OLRDs), photovoltaic devices, and other optical applications. Lasers have been used for removing coating on polymer substrate for flexible display and electronic industry. In selective removal of ITO layer, laser wavelength, pulse energy, scan speed, and the repetition rate of pulses determine conditions, which are efficient for removal of ITO coating without affecting properties of the polymer substrate. ITO coating removal with a laser is more environmentally friendly than other conventional etching methods. In this paper, pattering of ITO film from polymer substrates is described. The Yb:KGW femtosecond laser processing system with a pulse duration of 250fs, a wavelength of 1030nm and a repetition rate of 100kHz was used for removing ITO coating in air. We can remove the ITO coating using a scanner system with various pulse energies and scan speeds. We observed that the amount of debris is minimal through an optical and a confocal microscope, and femtosecond laser pulses with 1030nm wavelength are effective to remove ITO coating without the polymer substrate ablation.

  • PDF

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

Airway Responses to Bronchoprovocation Using High-Resolution Computed Tomography in Patients with Bronchial Asthma (기관지천식환자에 있어서 고해상도 전산화단층촬영술을 이용한 기관지유발에 대한 기도의 반응)

  • Choi, Byoung-Whui;Kang, Yoon-Jeong;Ko, Hyung-Ki;Park, In-Won;Hue, Sung-Ho;Kim, Yang-Soo;Kim, Young-Goo;Kim, Kun-Sang;Kim, Jong-Hyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.813-822
    • /
    • 1995
  • Background: Bronchial hyperresponsiveness and abnormal response such as a loss of distensibility are pathophysiologic characteristics if bronchial asthma. The only means of direct in vivo measurement of airway size had been a tantalium bronchography, until high-resolution computed tomography(HRCT) enabled to measure noninvasively two dimensional airway area more accurately and reliably. Method: To investigate airway area responses to bronchial provocation with methacholine and evaluate the major sites of bronchial constriction in patients with bronchial asthma. We examined HRCT scans in five patients with bronchial asthma who had significant bronchoconstriction(20% or more decrease in $FEV_1$) using CT scanner(5,000T CT, Shimadzu Co, Japan) before and in 3~5 min. after methacholine inhalation. Airways which were matched by parenchymal anatomic landmarks in each patient before and after methacholine inhalation were measured using film scanner(TZ-3X scanner; Truvel Co. Chatsworth CA, USA) and a semiautomated region growing method. Results: 1) We identified 9 to 12 airways in each patient which were matched by parenchymal anatomic landmarks before and after methacholine inhalation. 2) Airway responses to methacholine are quite different even in a patient. 3) The constriction of small airways(average diameter <2 mm; area < $3.14mm^2$) was 48.7%(8.3; SEM, n=43), being more prominant than that of large airways(average diameter >2 mm; area > $3.14mm^2$), 53.8% (4.4;SEM, n=10), but not significantly different(p>0.05). 4) There was no significant difference in the degree of constriction between upper(44.3% +5.8; mean + SEM, n=30) and lower lung regions(56.7% +4.5, n=23). Conclusions: Thus airway responses to methacholine bronchoprovocation is quite variable in a patient with bronchial asthma and has no typical pattern in patients with bronchial asthma.

  • PDF

Analysis of Changes in Skin Dose During Weight Loss when Tomotherapyof Nasopharynx Cancer (비인두암 토모테라피 시 체중 감소에 따른 피부선량 변화 분석)

  • Jang, Joon-Young;Kim, Dae Hyun;Choi, Cheon Woong;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.99-104
    • /
    • 2016
  • For patients receiving chemotherapy and radiation therapy treatment progresses as vomiting, nausea, weight of the patient because of a loss of appetite it is reduced. The patient's weight and the distance from the skin and the treatment site is expected to be closer, thereby reducing the change in the skin because of this dose. This study tests using a loose see the difference between the volume change appears as the weight of the patient using the same phantom and the phantom body of the patient. To using the same as the position EBT film is attached to the skin of the treatment site and was adjusted to the thickness of the Bolus. And using a computerized treatment planning only tomotherapy equipment was passed under the conditions according to the thickness of the radiation dose. To baseline for accurate reproduction position using the MVCT was applied to treated with verification. By passing a total of three dose reduced the error, it was a measure of the film by using a dedicated scanner, EBT VIDAR scanner. Got an increase in the skin dose is displayed each time the thickness of the bolus reduced, in a bolus was completely removed with the highest value. If the changes appeared dose was greater weight loss patients to chemotherapy and therefore bolus thickness variation considering the weight loss of the patient when applying the tomotherapy of nasopharynx cancer was found that the increase in skin dose be increased. This large patient before treatment due to weight loss over the image verification is considered to be established should consider how to re-create your mask and treatment plan for fixing it.

Evaluation of Dose Distribution Using Gafchromic $EBT^{(R)}$ Film (Gafchromic $EBT^{(R)}$ 필름을 이용한 선량분포의 평가)

  • Kang, Se-Sik;Ko, Seong-Jin;Jang, Eun-Sung
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2007
  • Dose evaluation for small field such as stereotactic radiosurgery was performed using $Gafchromic^{(R)}$ EBT film. Every film which irradiated 6MV photon beam was scanned and obtained the optical density(OD) by flat bed scanner after 24 hours of irradiation. This study compared dose from diode in water and Gafchromic $EBT^{(R)}$ film in acrylic phantom to verify the reliability of the film, and to evaluate the SRS in clinical dose distributions from calculation and measurement in the region of virtual target in humanoid and cylindrical phantoms were compared. The Gafchromic $EBT^{(R)}$ film was found to be linear up to 9Gy. The $D_{max}$ for 6 MV was measured at 1.5 cm from the surface by both of diode and the film. As the depth is deeper, the error was measured within $2{\sim}3%$ at $10{\sim}20\;cm$ depth. Comparing between distribution from calculation and measurement, we found that there is 5% error at 90% isodose line. We found that given dose could be measured accurately by using the phantoms. It was feasible to use the Gafchromic $EBT^{(R)}$ film in quality assurance of SRS.

  • PDF

Computer-Aided Diagnosis System for the Detection of Breast Cancer (유방암검출을 위한 컴퓨터 보조진단 시스템)

  • Lee, C.S.;Kim, J.K.;Park, H.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.319-322
    • /
    • 1997
  • This paper presents a CAD (Computer-Aided Diagnosis) system or detection of breast cancer, which is composed of personal computer, X-ray film scanner, high resolution display and application softwares. There are three major algorithms implemented in the application software. The irst algorithm is the adaptive enhancement of the digitized X-ray mammograms based on the first derivative and the local statistics. The second one is to detect the clustered microcalcifications by using the statistical texture analysis, and the third one is the classification of the clustered microcalcifications as malignant or benign by using the shape analysis. These algorithms were verified by real experiments.

  • PDF